超短回波时间T1定量检测皮质骨钆沉积:兔模型离体研究
在28只新西兰兔中比较对照组、大环状低剂量组、大环状高剂量组和线性钆对比剂组,用7T动物扫描仪的超短回波时间T1定量测量胫骨皮质骨T1值,并以电感耦合等离子体质谱测钆浓度;三个钆对比剂组皮质骨T1值均低于对照组,R1值与钆浓度强正相关(r=0.73,p<0.001)。作者认为超短回波时间T1定量有潜力无创评估钆对比剂给药后的皮质骨钆沉积。
要点
- 兔模型中线性钆对比剂组皮质骨T1值最低(296.8±24.1 ms),钆浓度最高(13.62±1.55 μg/g)。
- R1值与皮质骨钆浓度强正相关(r=0.73,p<0.001)。
- 超短回波时间T1定量可能无创监测皮质骨钆沉积。
诊断标准与关键数值
- 皮质骨T1值:对照组356.3±19.4 ms,大环状低剂量组329.2±21.0 ms(p<0.05),大环状高剂量组316.8±21.7 ms(p<0.01),线性钆对比剂组296.8±24.1 ms(p<0.001)。
- 电感耦合等离子体质谱测皮质骨钆浓度:对照组0.04±0.02 μg/g,大环状低剂量组2.60±0.48 μg/g,大环状高剂量组4.95±1.17 μg/g,线性钆对比剂组13.62±1.55 μg/g。
- R1值与皮质骨钆浓度强正相关(r=0.73,p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the capacity of ultrashort echo time (UTE) T1 mapping to non-invasively assess gadolinium deposition in cortical bone after gadolinium-based contrast agent (GBCA) administration.
METHODS: Twenty-eight New Zealand rabbits (male, 3.0-3.5 kg) were randomly allocated into control, macrocyclic, high-dose macrocyclic, and linear GBCA groups (n = 7 for each group), and respectively given daily doses of 0.9 ml/kg bodyweight saline, 0.3 mmol/kg bodyweight gadobutrol, 0.9 mmol/kg bodyweight gadobutrol, and 0.3 mmol/kg bodyweight gadopentetate dimeglumine for five consecutive days per week over a period of 4 weeks. After a subsequent 4 weeks of recovery, the rabbits were sacrificed and their tibiae harvested. T1 value of cortical bone was measured using a combination of UTE actual flip angle imaging and variable repetition time on a 7T animal scanner. Gadolinium concentration in cortical bone was measured using inductively coupled plasma mass spectrometry (ICP-MS). Pearson's correlation between R1 value (R1 = 1/T1) and gadolinium concentration in cortical bone was assessed.
RESULTS: Bone T1 values were significantly lower in the lower-dose macrocyclic (329.2 ± 21.0 ms, p < 0.05), higher-dose macrocyclic (316.8 ± 21.7 ms, p < 0.01), and linear (296.8 ± 24.1 ms, p < 0.001) GBCA groups compared with the control group (356.3 ± 19.4 ms). Gadolinium concentrations measured by ICP-MS in the control, lower-dose macrocyclic, higher-dose macrocyclic, and linear GBCA groups were 0.04 ± 0.02 μg/g, 2.60 ± 0.48 μg/g, 4.95 ± 1.17 μg/g, and 13.62 ± 1.55 μg/g, respectively. There was a strong positive correlation between R1 values and gadolinium concentrations in cortical bone (r = 0.73, p < 0.001).
CONCLUSIONS: These results suggest that UTE T1 mapping has the potential to provide a non-invasive assessment of gadolinium deposition in cortical bone following GBCA administration.
KEY POINTS: • Changes in T1 value related to gadolinium deposition were found in bone after both linear and macrocyclic GBCA administrations. • R1 relaxometry correlates strongly with gadolinium concentration in cortical bone. • UTE T1 mapping provides a potential tool for non-invasively monitoring gadolinium deposition in cortical bone.
引用
- Zhao K, Li S, Yi P, et al. Detection of gadolinium deposition in cortical bone with ultrashort echo time T1 mapping: an ex vivo study in a rabbit model. Eur Radiol. 2020. PMID: 32929642. doi:10.1007/s00330-020-07258-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。