胸腹部双能CT碘浓度的个体内一致性

Intraindividual Consistency of Iodine Concentration in Dual-Energy Computed Tomography of the Chest and Abdomen.
PubMed 文献 · Invest Radiol · 2021-01-01

回顾性纳入159例患者共469次重复胸腹部门静脉期双能CT检查,测量43个感兴趣区的碘浓度;各区域组内相关系数为0.642–0.936,改良变异系数为1.8%–25.4%,以主动脉归一化后改良变异系数为5.8%[1.8%–15.8%],低于未归一化数据及以触发延迟归一化数据。

要点

  • 双能CT碘浓度在个体内纵向随访中存在变异,各区域改良变异系数为1.8%–25.4%。
  • 以主动脉归一化后改良变异系数为5.8%[1.8%–15.8%],低于未归一化及以触发延迟归一化数据。
  • 各感兴趣区组内相关系数为0.642–0.936,无论是否归一化或采用何种归一化技术。

核心结论

  • 研究证实双能CT所得碘浓度存在个体内纵向变异,变异程度因血管、淋巴结、器官和结缔组织的灌注特征不同而异。
  • 在固定对比剂注射方案下,以主动脉归一化似乎可提高可重复性。

研究设计与样本

  • 回顾性纳入159例患者,共469次重复(范围2–4次)临床指征的胸腹部门静脉期双能CT检查。
  • 影像检查时经随访影像(≥3个月)排除宏观肿瘤负荷。
  • 基于43个感兴趣区测量实质器官、血管、淋巴结和结缔组织的碘浓度,并行主动脉归一化及触发延迟归一化。
  • 采用组内相关系数和改良变异系数评估个体内一致性及变异,并采用t检验和方差分析(Tukey-Kramer事后检验)进行统计。

诊断标准与关键数值

  • 所有感兴趣区的平均组内相关系数为0.642–0.936,无论是否归一化或采用何种归一化技术。
  • 总体改良变异系数为1.8%–25.4%。
  • 以主动脉归一化数据改良变异系数为5.8%[1.8%–15.8%],低于未归一化数据(P<0.01)及以触发延迟归一化数据(P=0.04)。

临床应用与阅片要点

  • 在固定对比剂注射方案下,以主动脉归一化似乎可提高双能CT碘浓度测量的可重复性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Dual-energy computed tomography (DECT)-derived quantification of iodine concentration (IC) is increasingly used in oncologic imaging to characterize lesions and evaluate treatment response. However, only limited data are available on intraindividual consistency of IC and its variation. This study investigates the longitudinal reproducibility of IC in organs, vessels, and lymph nodes in a large cohort of healthy patients who underwent repetitive DECT imaging.

MATERIALS AND METHODS: A total of 159 patients, who underwent a total of 469 repetitive (range, 2-4), clinically indicated portal-venous phase DECT examinations of the chest and abdomen, were retrospectively included. At time of imaging, macroscopic tumor burden was excluded by follow-up imaging (≥3 months). Iodine concentration was measured region of interest-based (N = 43) in parenchymatous organs, vessels, lymph nodes, and connective tissue. Normalization of IC to the aorta and to the trigger delay as obtained from bolus tracking was performed. For statistical analysis, intraclass correlation coefficient and modified variation coefficient (MVC) were used to assess intraindividual agreement of IC and its variation between different time points, respectively. Furthermore, t tests and analysis of variance with Tukey-Kramer post hoc test were used.

RESULTS: The mean intraclass correlation coefficient over all regions of interest was good to excellent (0.642-0.936), irrespective of application of normalization or the normalization technique. Overall, MVC ranged from 1.8% to 25.4%, with significantly lower MVC in data normalized to the aorta (5.8% [1.8%-15.8%]) in comparison with the MVC of not normalized data and data normalized to the trigger delay (P < 0.01 and P = 0.04, respectively).

CONCLUSIONS: Our study confirms intraindividual, longitudinal variation of DECT-derived IC, which varies among vessels, lymph nodes, organs, and connective tissue, following different perfusion characteristics; normalizing to the aorta seems to improve reproducibility when using a constant contrast media injection protocol.

来源:Invest Radiol,查看原文。版权归原作者所有。