文献速递儿科影像技术与安全US

高频超声在婴幼儿血管瘤治疗中的临床应用

Clinical Application of High-frequency Ultrasound in Treatment of Infantile Hemangiomas.
PubMed 文献 · J Ultrasound Med · 2020-09-12

研究纳入80例婴幼儿血管瘤患者,于治疗前及治疗后1、3、5个月行高频超声动态监测,比较肿瘤大小、内部回声及血流动力学参数。治疗有效组70例中肿瘤厚度均减小,血流信号、收缩期峰值流速、阻力指数及静脉流速均有改变;治疗无效组10例上述指标无显著差异。作者认为高频超声在治疗监测中有主要应用价值,肿瘤厚度变化是最重要的观察指标。

要点

  • 治疗有效组70例肿瘤厚度均减小,厚度变化是最重要的观察指标。
  • 治疗有效组中血流信号减少55例、收缩期峰值流速下降55例、阻力指数升高55例、静脉流速下降53例。
  • 治疗无效组10例上述指标治疗前后无显著差异(P > 0.05)。

关键影像表现/征象

  • 治疗有效组70例肿瘤厚度均减小,55例血流信号减少,55例收缩期峰值流速下降,55例阻力指数升高,53例静脉流速下降。
  • 治疗有效组治疗后5个月肿瘤厚度较治疗1个月和2个月时显著减小(P < 0.05)。
  • 治疗有效组治疗后肿瘤纵径和横径无显著差异(P > 0.05)。
  • 治疗无效组10例治疗前后上述指标均无显著差异(P > 0.05)。

诊断标准与关键数值

  • 治疗有效组治疗前后肿瘤厚度、血流信号、收缩期峰值流速、阻力指数及静脉流速差异有统计学意义(P < 0.05)。
  • 治疗有效组治疗5个月时肿瘤厚度较1个月和2个月时显著减小(P < 0.05)。
  • 治疗有效组治疗后肿瘤纵径与横径差异无统计学意义(P > 0.05)。
  • 治疗无效组治疗前后上述指标差异无统计学意义(P > 0.05)。

临床应用与阅片要点

  • 作者认为高频超声可用于婴幼儿血管瘤治疗监测,肿瘤厚度变化是最重要的观察指标。
  • 治疗有效组中血流信号、收缩期峰值流速、阻力指数及静脉流速出现相应改变,治疗无效组则无显著变化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To study the clinical application of high-frequency ultrasound in the treatment of infantile hemangiomas.

METHODS: Ultrasonographic data before and after treatment for 1 month, 3 months and 5 months were recorded from 80 patients with infantile hemangioma. The hemangioma was monitored dynamically with relevant indexes before and after treatment, and the treatment results were divided into 2 groups: the treatment-effective group of 70 cases and the treatment-ineffective group of 10 cases. The differences of tumor size, internal echo and hemodynamic parameters (peak arterial systolic flow velocity, resistance index and venous velocity) were compared before and after treatment, and reliable ultrasound observation indexes were summarized.

RESULTS: After treatment, in the treatment-effective group, the thickness of tumor was reduced in all cases, the blood flow signals decreased in 55 cases, the peak systolic velocity decreased in 55 cases, resistance index increased in 55 cases, and venous flow velocity decreased in 53 cases; the differences were statistically significant compared with those before treatment (P < 0.05). The thickness of tumors was significantly decreased after 5 months of treatment compared with 1 month and 2 month treatment (P < 0.05). There was no significant difference in the longitudinal and transverse diameter of tumors after treatment (P > 0.05). In the treatment-ineffective group, there was no significant difference in the above indexes before and after treatment (P > 0.05).

CONCLUSION: High-frequency ultrasound had primary application value in the treatment of infantile hemangiomas, where the change of tumor thickness provided the most important observational indicator.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Meng H, Jiang L, Chen Z, et al. Clinical Application of High-frequency Ultrasound in Treatment of Infantile Hemangiomas. J Ultrasound Med. 2020. PMID: 32918313. doi:10.1002/jum.15485

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。