食管纽扣电池内镜取出后系列MRI表现
回顾性分析19例儿童食管纽扣电池内镜取出后的系列MRI,17例在取出后48小时内行MRI者均见广泛纵隔水肿,水肿紧邻大血管,近端食管损伤者水肿均邻近气道;3/10例近端损伤和4/7例中远端损伤见动脉血管改变,8/10例近端损伤见气道改变;系列MRI显示气道改变均改善,中远端损伤者血管壁改变除1例外均改善;4例食管造影见包裹性食管漏,无气管食管瘘或血管肠瘘发生。
要点
- 取出后48小时内MRI常见广泛纵隔水肿,水肿可直接紧邻大血管和气道。
- 近端食管损伤者气道改变发生率为80%(8/10),系列MRI显示均改善。
- 中远端食管损伤者血管壁改变发生率为57%(4/7),系列MRI显示除1例外均改善。
关键影像表现/征象
- 取出后48小时内行MRI的17例均见广泛纵隔水肿。
- 17例水肿均直接紧邻大血管,10例近端食管损伤者水肿均紧邻气道。
- 近端食管损伤者30%(3/10)见动脉血管改变,中或远端食管损伤者57%(4/7)见动脉血管改变。
- 近端食管损伤者80%(8/10)见气道改变。
- 系列MRI显示所有患者气道改变均改善,中或远端食管损伤者血管壁改变除1例(25%,1/4)外均改善。
局限性
- 原文结论指出需进一步研究以确定对气管食管瘘和血管肠瘘等严重并发症最敏感和特异的影像表现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to evaluate findings at serial MRI after endoscopic removal of a button battery from the esophagus in a series of pediatric patients. MATERIALS AND METHODS. Serial MRI examinations after removal of a button battery from the esophagus were reviewed retrospectively for the presence of mediastinal edema; imaging characteristics of the aorta and arteries; imaging characteristics of the trachea; and imaging characteristics of the esophageal wall at the level of injury. RESULTS. A total of 48 MRI examinations were performed on 19 patients, 89% (17/19) in the first 48 hours after battery removal. Serial MRI was performed for 84% (16/19) of patients. Initial MRI showed extensive mediastinal edema in all 17 patients who underwent MRI in the first 48 hours. Edema directly abutted major arteries in all 17 patients and abutted the airway in all 10 patients with proximal esophageal injury. Arterial vascular changes were seen in 30% (3/10) of patients with proximal esophageal injury and 57% (4/7) of patients with mid or distalesophageal injury. Airway changes were seen in 80% (8/10) of patients with proximal esophageal injury. Serial MRI showed improvement of airway changes in all patients and improvement in vessel wall changes in all but one (25%, 1/4) of the patients who had mid or distal esophageal injury. Four patients (21% [4/19]) had contained esophageal leak on esophagrams. No patients in our series developed a tracheoesophageal or vascular-enteric fistula. CONCLUSION. Our case series provides important information on natural history of MRI findings in children after endoscopic removal of a button battery from the esophagus. Further studies are needed to determine the imaging findings most sensitive and specific for severe complications, such as tracheoesophageal fistula and vascular-enteric fistula.
引用
- Riedesel EL, Richer EJ, Sinclair EM, et al. Serial MRI Findings After Endoscopic Removal of Button Battery From the Esophagus. AJR Am J Roentgenol. 2020. PMID: 32960667. doi:10.2214/AJR.19.22427
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。