MRI测量胫骨结节-滑车沟距离:膝关节位置误差的评估与校正
内收组校正后平均增加2.4 mm,外展组平均减少2.3 mm,偏差与校正差值高度相关(r²=0.96),ICC优良但一致性界限接近±3 mm。作者提出一种简单的膝关节位置校正方法。
要点
- 膝关节内收或外展位可导致TTTG距离出现系统性测量误差。
- 内收位校正后TTTG平均增加2.4 mm,外展位校正后平均减少2.3 mm。
- 观察者信度ICC优良,但Bland-Altman一致性界限接近±3 mm。
核心结论
- MRI测量TTTG距离受膝关节内收或外展位置引起的系统性技术误差影响。
- 作者建议一种简单的校正方法用于调整膝关节位置。
研究设计与样本
- MRI包含三维矢状面序列,覆盖胫骨近端至少8 cm。
- 使用三维可视化软件构建胫骨近端中心纵轴,在校正前后测量TTTG距离。
- 观察者信度采用组内和组间相关系数(ICC)及Bland-Altman图评估。
关键影像表现/征象
- 26例膝关节呈内收位,平均2.7°(范围0.0°至9.4°)。
- 20例膝关节呈外展位,平均2.6°(范围0.0°至7.2°)。
诊断标准与关键数值
- 内收位校正后TTTG距离平均增加2.4 mm(范围0.0至6.7 mm)。
- 外展位校正后TTTG距离平均减少2.3 mm(范围0.0至5.5 mm)。
- 内收/外展偏差与校正前后TTTG差值之间的相关系数r²=0.96。
- ICC优良,但一致性界限接近±3 mm。
临床应用与阅片要点
- 阅片测量TTTG距离时需注意膝关节内收或外展位置带来的系统性误差。
- 作者建议采用其简单方法对膝关节位置进行校正。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The tibial tuberosity-trochlear groove (TTTG) distance varies with the position of the knee in the MR or CT scanner. We present and assess a simple method for adjustment of adduction or abduction of the knee.
MATERIALS AND METHODS: MRI of the knee encompassing a three-dimensional (3D) sagittal sequence including ≥ 8 cm of the proximal tibia was analyzed (29 females, 17 males; median age 45 years). Using 3D visualization software, the central longitudinal axis of the proximal tibia (TA) was constructed, and the TTTG distance was measured before and after alignment of the TA. Observer reliability was assessed with inter- and intra-class correlation coefficient (ICC) and Bland-Altman plots.
RESULTS: Adduction of the knee occurred in 26 examinations, mean 2.7° (range 0.0° to 9.4°), and abduction in 20 examinations, mean 2.6° (range 0.0° to 7.2°). Following adjustment, the mean TTTG distance increased 2.4 mm (range 0.0 to 6.7 mm) in the knees positioned in adduction and decreased 2.3 mm when in abduction (range 0.0 to 5.5 mm). The correlation coefficient (r2) between the deviation in adduction and abduction and the difference between TTTG unadjusted and adjusted was r2 = 0.96. ICCs were excellent, but limits of agreement were close to ± 3 mm.
CONCLUSION: Measurement of the TTTG distance by MRI is influenced by a systematic technique-dependent error caused by knee positioning in adduction or abduction. We suggest a simple method for adjusting the positioning.
引用
- Egund N, Skou N, Jacobsen B, et al. Measurement of tibial tuberosity-trochlear groove distance by MRI: assessment and correction of knee positioning errors. Skeletal Radiol. 2020. PMID: 32970161. doi:10.1007/s00256-020-03605-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。