文献速递骨肌神经MR

T1加权动态对比增强MRI鉴别脊柱非肿瘤性与恶性椎体病变

T1-weighted Dynamic Contrast-enhanced MRI to Differentiate Nonneoplastic and Malignant Vertebral Body Lesions in the Spine.
PubMed 文献 · Radiology · 2020-09-01

本回顾性研究纳入2015年5月至2018年5月间接受脊柱动态对比增强灌注MRI及病变活检的患者,比较非肿瘤性(51个)与恶性(83个)椎体病变的 fractional plasma volume(Vp)。非肿瘤性病变Vp低于恶性病变(1.6±1.3 vs 4.2±3.0,P<.001),Vp鉴别两者的敏感度93%、特异度78%、AUC 0.88。

要点

  • 非肿瘤性椎体病变的Vp低于恶性病变(1.6±1.3 vs 4.2±3.0,P<.001)。
  • Vp鉴别非肿瘤性与恶性椎体病变的敏感度93%、特异度78%、AUC 0.88。
  • Vp测量的一致性:读者内κ=0.72、读者间κ=0.70,均提示高度一致。

关键影像表现/征象

  • 非肿瘤性病变的Vp低于恶性病变(1.6±1.3 vs 4.2±3.0,P<.001)。

诊断标准与关键数值

  • Vp鉴别非肿瘤性与恶性病变的敏感度为93%(77/83;95%CI:85%,97%)。
  • Vp鉴别非肿瘤性与恶性病变的特异度为78%(40/51;95%CI:65%,89%)。
  • Vp鉴别非肿瘤性与恶性病变的AUC为0.88(95%CI:0.82,0.95)。
  • 读者内一致性κ=0.72,读者间一致性κ=0.70,均提示高度一致。

临床应用与阅片要点

  • DCE灌注MRI参数Vp可用于辅助鉴别脊柱非肿瘤性与恶性椎体病变。
  • 测量Vp时,感兴趣区由两名研究者手动在椎体上勾画,并采用Tofts药代动力学两室模型计算。
  • Vp可归一化至相邻正常椎体后进行组间比较。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Dynamic contrast agent-enhanced (DCE) perfusion MRI may help differentiate between nonneoplastic and malignant lesions in the spine. Purpose To investigate the correlation between fractional plasma volume (Vp), a parameter derived from DCE perfusion MRI, and histopathologic diagnosis for spinal lesions. Materials and Methods In this retrospective study, patients who underwent DCE perfusion MRI and lesion biopsy between May 2015 and May 2018 were included. Inclusion criteria were short time interval (<30 days) between DCE perfusion MRI and biopsy, DCE perfusion MRI performed before biopsy, and DCE perfusion MRI performed at the same spine level as biopsy. Exclusion criteria were prior radiation treatment on vertebrae of interest, poor DCE perfusion MRI quality, nondiagnostic biopsy, and extensive spinal metastasis or prior kyphoplasty. One hundred thirty-four lesions were separated into a nonneoplastic group (n = 51) and a malignant group (n = 83) on the basis of histopathologic analysis. Two investigators manually defined regions of interest in the vertebrae. DCE perfusion MRI parameter Vp was calculated by using the Tofts pharmacokinetic two-compartment model. Vp was quantified, normalized to adjacent normal vertebrae, and compared between the two groups. A Mann-Whitney U test and receiver operating characteristic analysis was performed to verify the difference in Vp between the nonneoplastic and malignant groups. Reproducibility was assessed by calculating the Cohen κ coefficient. Results One hundred patients (mean age, 65 years ± 11 [standard deviation]; 52 men) were evaluated. Vp was lower in nonneoplastic lesions versus malignant lesions (1.6 ± 1.3 vs 4.2 ± 3.0, respectively; P < .001). The sensitivity of Vp was 93% (77 of 83; 95% confidence interval [CI]: 85%, 97%), specificity was 78% (40 of 51; 95% CI: 65%, 89%), and area under the receiver operating characteristic curve was 0.88 (95% CI: 0.82, 0.95). Cohen κ coefficient suggested substantial agreement in both intra- (κ = 0.72) and interreader (κ = 0.70) reproducibility. Conclusion This study indicated that dynamic contrast agent-enhanced perfusion MRI parameter, fractional plasma volume, was able to differentiate between nonneoplastic spinal lesions and malignant lesions. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Haller in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Guan Y, Peck KK, Lyo J, et al. T1-weighted Dynamic Contrast-enhanced MRI to Differentiate Nonneoplastic and Malignant Vertebral Body Lesions in the Spine. Radiology. 2020. PMID: 32870135. doi:10.1148/radiol.2020190553

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。