关节镜下肩峰成形术后肩峰与肩峰下形态的磁共振成像评估

Assessment of postoperative acromial and subacromial morphology after arthroscopic acromioplasty using magnetic resonance imaging.
PubMed 文献 · Skeletal Radiol · 2020-09-25

研究对100例关节镜下肩袖修复联合肩峰成形术患者行术前、术后即刻及术后8个月至1年三次MRI检查,评估肩峰厚度与形态及肩峰下滑囊间隙变化。术后第二次MRI显示肩峰平均变薄32%,91%患者出现局限性积液;肩峰厚度变化与临床及影像因素无统计学显著关联(P值>0.05)。作者认为术后约1年内肩峰显著延迟变薄是正常术后特征,肩峰下滑囊局限性囊样积液可能是肩峰变薄的重要相关因素。

要点

  • 关节镜下肩峰成形术后约1年内肩峰平均变薄32%,属延迟性改变。
  • 术后第二次MRI随访时91%患者出现肩峰下滑囊局限性积液。
  • 部分患者肩峰下表面呈过度凹陷轮廓,需与肩峰变薄同时评估。

核心结论

  • 关节镜下肩峰成形术后约1年内肩峰厚度显著延迟变薄,作者认为属正常术后特征。
  • 肩峰下滑囊局限性囊样积液可能是术后肩峰变薄的重要相关因素。

研究设计与样本

  • 研究纳入100例接受关节镜下肩袖修复联合肩峰成形术的患者。
  • 每例患者至少接受三次MRI检查:术前、术后第一次即刻及术后8个月至1年第二次随访。
  • 评估术后肩峰厚度与形态随时间变化及肩峰下滑囊间隙改变。
  • 分析临床与影像参数与肩峰形态变化的相关性。

关键影像表现/征象

  • 术后第一次即刻MRI示肩峰仅轻微变薄,术后第二次MRI示肩峰显著变薄,平均减少32%。
  • 肩峰变薄同时,部分患者肩峰下表面呈过度凹陷轮廓。
  • 术后第二次随访时91%患者肩峰下间隙出现局限性积液。
  • 术后肩峰厚度变化与临床或影像因素无统计学显著关联(P值>0.05)。

诊断标准与关键数值

  • 肩峰厚度变化以MRI测量评估,术后第二次MRI较术前平均减少32%。
  • 肩峰下滑囊局限性积液于术后第二次随访时见于91%患者。
  • 肩峰厚度变化与临床及影像因素关联分析P值>0.05,无统计学显著关联。

临床应用与阅片要点

  • 阅片时需注意关节镜下肩峰成形术后肩峰延迟变薄可呈正常术后表现。
  • 报告肩峰形态时应描述肩峰下表面凹陷轮廓及肩峰下滑囊局限性积液。
  • 术后约1年内随访MRI见肩峰变薄与局限性积液时,可结合作者结论理解为术后相关改变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To identify the morphological characteristics of the acromion and subacromial bursal space after arthroscopic acromioplasty using magnetic resonance imaging (MRI).

MATERIALS AND METHODS: One hundred patients who received arthroscopic rotator cuff repair and acromioplasty each received at least three MRI examinations (preoperative, first immediate postoperative, and second follow-up imaging between 8 months and 1 year postoperatively). Changes over time in the thickness and morphology of the postoperative acromion as well as the subacromial bursal space were assessed. Clinical and radiological parameters were also analyzed to identify any association with changes in acromial morphology.

RESULTS: Despite minimal acromial thinning observed at the first immediate postoperative state, the acromions showed significant thinning at the second postoperative MRI, with a mean reduction of 32%. Along with acromial thinning, an exaggerated concave contour of the acromial undersurface was observed in some patients. In the subacromial space, a loculated fluid collection developed in 91% of the patients at the second postoperative follow-up. No statistically significant association was noted between postoperative acromial thickness change and clinical or radiological factors (P value > 0.05).

CONCLUSION: A significant delayed reduction in acromial thickness within approximately 1 year of arthroscopic acromioplasty is thought to be a normal postoperative feature. The simultaneous collection of a loculated, cyst-like fluid in the subacromial bursal space may be an important associated factor of postoperative acromial thinning.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Kang HJ, Park JS, Ryu KN, et al. Assessment of postoperative acromial and subacromial morphology after arthroscopic acromioplasty using magnetic resonance imaging. Skeletal Radiol. 2020. PMID: 32978678. doi:10.1007/s00256-020-03607-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。