超声造影引导下肌肉骨骼活检:我们的经验与技术
本研究报告一家繁忙介入门诊连续36例超声造影引导下肌肉骨骼软组织活检的经验:所有操作使用16G穿刺针,均获得足以病理分析的组织;15例有手术切除标本对照中14例(93%)结果一致;仅1例出现微泡破裂时短暂腿部不适,无其他不良事件或操作并发症。作者认为超声造影可安全、准确靶向软组织病灶的代表性区域。
要点
- 超声造影引导下肌肉骨骼软组织活检36例均获得足以病理分析的组织,无严重并发症。
- 15例有手术切除对照者中14例(93%)活检与切除标本病理诊断一致。
- 术前增强MRI示10/30例(33%)病灶有可疑坏死区,作者强调靶向异质性病灶的代表性区域。
核心结论
- 作者认为超声造影是安全靶向软组织病灶代表性区域进行活检的准确方法,可在繁忙介入门诊开展;早期经验显示该技术有前景,尤其适用于靶向异质性病灶及既往影像提示可疑坏死的病灶。
研究设计与样本
- 回顾性研究,经IRB批准并豁免知情同意,回顾2018年12月1日至2020年3月2日所有超声造影引导下肌肉骨骼活检。
- 共32例患者(平均年龄57岁,范围26–88岁;男22例、女10例)接受36次活检,均使用16G穿刺针。
- 记录取材针数、术前影像可疑坏死、标本是否足以病理分析、与手术切除标本病理诊断的一致性及操作并发症。
关键影像表现/征象
- 每次操作获取2–7条核心标本(平均3.7条);所有操作均获得足以病理分析的组织。
- 30/36例(83%)术前接受增强MRI,其中10/30例(33%)显示可疑坏死的影像特征。
- 15/36例随后行手术切除,核心活检与手术切除标本病理诊断一致14/15例(93%)。
- 1例在微泡破裂时出现短暂腿部不适,未观察到其他不良反应或操作并发症。
临床应用与阅片要点
- 作者认为超声造影可安全、准确地靶向软组织病灶的代表性区域进行活检,尤其适用于异质性病灶及既往影像提示可疑坏死的病灶。
- 作者早期经验显示该技术有前景,可在繁忙介入门诊实施。
局限性
- 原文为回顾性研究,经IRB批准并豁免知情同意。
- 作者称其为早期经验,并表述为有前景的技术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To present our experience with contrast-enhanced ultrasound (CEUS)-guided musculoskeletal soft tissue biopsies in a busy interventional clinic.
MATERIALS AND METHODS: After IRB approval was obtained and informed consent was waived, we retrospectively reviewed all CEUS-guided musculoskeletal biopsies performed from December 1, 2018 to March 2, 2020. Relevant pre-procedure imaging was reviewed. Number of samples, suspected necrosis on pre-procedure imaging, specimen adequacy for pathologic analysis, correlation with pathologic diagnosis of surgical resection specimens, and procedural complications were recorded.
RESULTS: Thirty-six CEUS-guided musculoskeletal biopsies were performed in 32 patients (mean age 57, range 26-88; 22 males, 10 females). All procedures were performed using 16-gauge biopsy needles, and all procedures provided adequate samples for pathologic analysis as per the final pathology report. Between two and seven core specimens were obtained (mean 3.7). In 30/36 cases (83%), a contrast-enhanced MRI was obtained prior to biopsy, and 10/30 (33%) of these cases showed imaging features suspicious for necrosis. In 15/36 cases, surgical resection was performed, and the core biopsy and surgical resection specimens were concordant in 14/15 cases (93%). One patient noted transient leg discomfort at the time of microbubble bursting. Otherwise, no adverse reactions or procedural complications were observed.
CONCLUSION: CEUS is an accurate way to safely target representative areas of soft tissue lesions for biopsy and can be implemented in a busy interventional clinic. Our early experience has shown this to be a promising technique, especially in targeting representative areas of heterogeneous lesions and lesions with areas of suspected necrosis on prior imaging.
引用
- Daniels SP, Mankowski Gettle L, Blankenbaker DG, et al. Contrast-enhanced ultrasound-guided musculoskeletal biopsies: our experience and technique. Skeletal Radiol. 2020. PMID: 32935196. doi:10.1007/s00256-020-03604-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。