弹性成像对细针穿刺细胞学检查报告为不确定的甲状腺结节的诊断可靠性:系统评价与贝叶斯Meta分析
该系统评价与贝叶斯Meta分析纳入20项研究共1734个FNAC报告为不确定的甲状腺结节,评估弹性成像的诊断效能。汇总敏感度和特异度分别为0.766(95%CrI 0.686-0.835)和0.867(95%CrI 0.780-0.931),AUC为0.743,诊断比值比为25.9(95%CrI 12.8-46.2)。作者结论认为弹性成像在不确定甲状腺结节中具有尚可的诊断效能,剪切波弹性成像和应变比弹性成像可能更有效,弹性成像联合超声有助于提高敏感度和特异度。
要点
- 弹性成像对FNAC不确定甲状腺结节的汇总敏感度0.766、特异度0.867,AUC为0.743。
- 剪切波弹性成像和应变比弹性成像比实时弹性成像更有效。
- 弹性成像联合其他超声技术可改善对不确定甲状腺结节的评估。
核心结论
- 弹性成像在FNAC不确定的甲状腺结节中具有尚可的诊断效能。
- 剪切波弹性成像和应变比弹性成像可能在诊断中更有效,并应在未来几年发展,而目前弹性成像联合超声将有助于提高敏感度和特异度。
研究设计与样本
- 系统评价与贝叶斯双变量Meta分析,检索Medline、Embase和Cochrane Central数据库至2019年10月31日,纳入20项研究共1734个FNAC报告为不确定的甲状腺结节。
- 由两名不同审稿人核查研究并提取数据,使用R语言贝叶斯双变量模型定量合成诊断准确性和效能。
- 参考标准为FNAC报告的不确定结节,评估弹性成像的诊断效能。
诊断标准与关键数值
- 弹性成像汇总敏感度为0.766(95%CrI 0.686-0.835),汇总特异度为0.867(95%CrI 0.780-0.931)。
- 汇总诊断比值比为25.9(95%CrI 12.8-46.2)。
- 汇总阳性似然比为6.6(95%CrI 4.2-11.3),汇总阴性似然比为0.27(95%CrI 0.21-0.36)。
- 汇总受试者工作特征曲线图显示右对角线曲线关系,提示敏感度与特异度之间存在权衡,AUC估计值为0.743。
- 剪切波弹性成像和应变比弹性成像比实时弹性成像更有效。
临床应用与阅片要点
- 弹性成像对FNAC不确定甲状腺结节的诊断效能为尚可,可作为辅助评估手段。
- 剪切波弹性成像和应变比弹性成像可能比实时弹性成像更有效。
- 弹性成像联合其他超声技术有助于提高对不确定甲状腺结节的敏感度和特异度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic yields of elastography in thyroid nodules reported as indeterminate in FNAC according to guidelines.
METHODS: Databases of Medline, Embase, and Cochrane Central were searched till 31 October 2019. Two different reviewers check the studies and extracted the data. The diagnostic accuracy and yield were quantitatively synthesized using Bayesian bivariate model in R.
RESULTS: Twenty studies with 1734 indeterminate thyroid nodules undergoing elastography were included. The summary estimates of sensitivity and specificity were 0.766 (95% credible interval (CrI), 0.686-0.835) and 0.867 (95% CrI, 0.780-0.931), respectively. The summary estimate for diagnostic odds ratio (DOR) was 25.9 (95% CrI, 12.8-46.2). Summary receiver operating characteristic plots for elastography showed a right-diagonal curvilinear relationship, suggesting a trade-off between sensitivity and specificity, and the estimate of area under curve (AUC) was 0.743. The summary estimates for positive and negative likelihood ratios were 6.6 (95% CrI, 4.2-11.3) and 0.27 (95% CrI, 0.21-0.36), respectively.
CONCLUSIONS: Elastography had fair diagnostic yields in indeterminate thyroid nodules. Shear wave elastography and strain ratio elastography could be more efficient in diagnosis and should evolve in the next years while combing elastography with ultrasound would contribute more to sensitivity and specificity currently.
KEY POINTS: • Elastography has fair diagnostic yields in indeterminate thyroid nodules. • Shear wave elastography and strain ratio elastography are more efficient than real-time elastography. • Combining elastography and other ultrasound techniques improves evaluation of indeterminate thyroid nodules.
引用
- Qiu Y, Xing Z, Liu J, et al. Diagnostic reliability of elastography in thyroid nodules reported as indeterminate at prior fine-needle aspiration cytology (FNAC): a systematic review and Bayesian meta-analysis. Eur Radiol. 2020. PMID: 32990793. doi:10.1007/s00330-020-07023-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。