文献速递甲状腺与浅表US

甲状腺剪切波弹性成像随预压力变化:定量验证

Variation of Shear Wave Elastography With Preload in the Thyroid: Quantitative Validation.
PubMed 文献 · J Ultrasound Med · 2020-09-20

研究纳入19名无甲状腺疾病健康志愿者,在2至10 N不同换能器预压力下对甲状腺左叶行剪切波弹性成像,采用线性混合效应模型分析预压力与硬度估计值的关联,发现预压力与弹性值呈显著非线性正相关。

要点

  • 甲状腺剪切波弹性成像的硬度测值随换能器预压力变化,2 N时为16.7 kPa,10 N时升至29.9 kPa。
  • 预压力与弹性估计值呈显著非线性关联,定量标准化预压力是提高甲状腺结节弹性评估准确性的关键因素。
  • 健康志愿者甲状腺弹性值在2 N预压力下为16.7 kPa(95%CI 14.1-19.3 kPa),在10 N下为29.9 kPa(95%CI 24.9-34.9 kPa)。

核心结论

  • 预压力与甲状腺剪切波弹性成像的硬度估计值呈显著非线性关联,定量标准化预压力是改善甲状腺结节弹性评估准确性的关键因素。

研究设计与样本

  • 研究为定量验证研究,纳入19名无已知甲状腺疾病的健康志愿者,在超声换能器上附加测力系统,于2至10 N预压力下对甲状腺左叶行剪切波弹性成像测量。
  • 采用线性混合效应模型量化预压力与硬度的关联,并校正同一参与者重复测量间的相关性;预压力效应用线性和二次项建模以考虑可能的非线性关联。

关键影像表现/征象

  • 健康志愿者甲状腺剪切波弹性成像估计值在2 N预压力时为16.7 kPa(95%CI 14.1-19.3 kPa),在10 N预压力时为29.9 kPa(95%CI 24.9-34.9 kPa)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Thyroid shear wave elastography (SWE) has been shown to have advantages compared to biopsy or other imaging modalities in the evaluation of thyroid nodules. However, studies show variability in its assessment. The objective of this study was to evaluate whether stiffness measurements of the normal thyroid, as estimated by SWE, varied due to preload force or the pressure applied between the transducer and the patient.

METHODS: In this study, a measurement system was attached to the ultrasound transducer to measure the applied load. Shear wave elastographic measurements were obtained from the left lobe of the thyroid at applied transducer forces between 2 and 10 N. A linear mixed-effects model was constructed to quantify the association between the preload force and stiffness while accounting for correlations between repeated measurements within each participant. The preload force effect on elasticity was modeled by both linear and quadratic terms to account for a possible nonlinear association between these variables.

RESULTS: Nineteen healthy volunteers without known thyroid disease participated in the study. The participants had a mean age ± SD of 36 ± 8 years; 74% were female; 74% had a normal body mass index; and 95% were white non-Hispanic/Latino. The estimated elastographic value at a 2-N preload force was 16.7 kPa (95% confidence interval, 14.1-19.3 kPa), whereas the value at 10 N was 29.9 kPa (95% confidence interval, 24.9-34.9 kPa).

CONCLUSIONS: The preload force was significantly and nonlinearly associated with SWE estimates of thyroid stiffness. Quantitative standardization of preload forces in the assessment of thyroid nodules using elastography is an integral factor for improving the accuracy of thyroid nodule evaluation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。