减少美国放射学会甲状腺影像报告与数据系统4类结节的不必要活检
这项回顾性研究最终纳入864例患者的922个美国放射学会甲状腺影像报告与数据系统4类结节,评估应变弹性成像(SE)、Virtual Touch组织成像与定量(VTIQ)及两者联合(SE+VTIQ)鉴别良恶性的效能。SE、VTIQ、SE+VTIQ的曲线下面积分别为0.751、0.817、0.844,联合技术虽敏感度略降,但可提高特异度和准确率,有助于减少不必要活检。
要点
- 对美国放射学会甲状腺影像报告与数据系统4类结节,SE+VTIQ联合诊断的曲线下面积最高(0.844)。
- 联合技术敏感度82.1%,低于VTIQ的86.3%,但特异度83.5%高于SE的77.7%和VTIQ的80.5%。
- 联合技术准确率80.2%,高于SE的70.6%和VTIQ的76.1%,有助于减少不必要活检。
核心结论
- 联合SE与VTIQ技术虽使敏感度略有下降,但可提高美国放射学会甲状腺影像报告与数据系统4类结节诊断的特异度和准确率,有助于减少不必要活检。
研究设计与样本
- 回顾性研究,初始纳入920例患者的985个甲状腺结节,最终纳入864例患者的922个美国放射学会甲状腺影像报告与数据系统4类结节,56例患者的63个结节因不符合纳入标准被排除。
- 所有结节均接受常规超声、SE和VTIQ检查,分别计算SE、VTIQ及SE+VTIQ的敏感度、特异度、准确率、阳性预测值和阴性预测值,并采用受试者工作特征曲线下面积分析评估诊断效能。
诊断标准与关键数值
- SE、VTIQ、SE+VTIQ诊断美国放射学会甲状腺影像报告与数据系统4类结节的敏感度分别为72.4%、86.3%、82.1%。
- SE、VTIQ、SE+VTIQ的特异度分别为77.7%、80.5%、83.5%。
- SE、VTIQ、SE+VTIQ的准确率分别为70.6%、76.1%、80.2%。
- SE、VTIQ、SE+VTIQ的阳性预测值分别为73.4%、76.3%、83.5%,阴性预测值分别为75.5%、79.7%、82.8%。
- SE、VTIQ、SE+VTIQ诊断美国放射学会甲状腺影像报告与数据系统4类结节的曲线下面积分别为0.751、0.817、0.844。
临床应用与阅片要点
- 对于美国放射学会甲状腺影像报告与数据系统4类结节,可联合应用SE与VTIQ技术辅助鉴别良恶性,以协助减少不必要活检。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the effectiveness of strain elastography (SE), Virtual Touch tissue imaging and quantification (VTIQ; Siemens Medical Solutions, Mountain View, CA) and their combination (SE + VTIQ) in distinguishing benign from malignant American College of Radiology Thyroid Imaging Reporting and Data System category 4 nodules (TR4) to reduce unnecessary biopsy.
METHODS: In this retrospective study, 985 thyroid nodules from 920 patients were initially enrolled and examined with conventional ultrasound, SE, and VTIQ. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SE, VTIQ, and SE + VTIQ were calculated respectively. An area under the receiver operating characteristic curve analysis was applied to evaluate the diagnostic efficiency of SE, VTIQ, and SE + VTIQ in the differentiation of benign and malignant TR4 nodules.
RESULTS: A total of 864 patients with 922 TR4 nodules were enrolled ultimately, as 63 thyroid nodules from 56 patients were excluded because they did not meet the inclusion criteria of this study. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SE, VTIQ, and SE + VTIQ were 72.4% versus 86.3% versus 82.1%, 77.7% versus 80.5% versus 83.5%, 70.6% versus 76.1% versus 80.2%, 73.4% versus 76.3% versus 83.5%, and 75.5% versus 79.7% versus 82.8%, respectively. The areas under the receiver operating characteristic curve for the diagnosis of TR4 nodules by SE, VTIQ, and SE + VTIQ were 0.751, 0.817, and 0.844.
CONCLUSIONS: In spite of a slight decrease in the sensitivity, the application of combining SE and VTIQ techniques can improve the specificity and accuracy of TR4 nodule diagnosis, which can help reduce unnecessary biopsies of TR4 nodules.
引用
- Xu L, Zhou Y, Li Y, et al. Reducing Unnecessary Biopsy of American College of Radiology Thyroid Imaging Reporting and Data System Category 4 Nodules. J Ultrasound Med. 2020. PMID: 32870530. doi:10.1002/jum.15391
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。