文献速递乳腺骨肌MR

酰胺质子转移加权成像与扩散峰度成像在乳腺癌诊断与评估中的价值比较研究

A comparative study of the value of amide proton transfer-weighted imaging and diffusion kurtosis imaging in the diagnosis and evaluation of breast cancer.
PubMed 文献 · Eur Radiol · 2020-09-04

本研究纳入135例女性,比较APTWI与DKI鉴别乳腺良恶性病变及分析参数与预后因素相关性的价值。恶性组Kapp高于良性组,Dapp和MTRasym(3.5 ppm)低于良性组(均p<0.001),Kapp与Dapp的AUC均高于MTRasym(3.5 ppm)。DKI在鉴别乳腺良恶性病变方面优于APTWI,各参数与部分预后因素存在一定程度相关。

要点

  • 恶性乳腺病变Kapp高于良性,Dapp和MTRasym(3.5 ppm)低于良性。
  • Kapp的AUC为0.913,Dapp为0.910,MTRasym(3.5 ppm)为0.796。
  • Kapp与病理分级中度相关(|r|=0.724),MTRasym(3.5 ppm)仅轻度相关(|r|=0.468)。

诊断标准与关键数值

  • 恶性组Kapp高于良性组,Dapp和MTRasym(3.5 ppm)低于良性组(均p<0.001)。
  • 鉴别良恶性的AUC:Kapp为0.913,Dapp为0.910,MTRasym(3.5 ppm)为0.796。
  • Kapp与MTRasym(3.5 ppm)的AUC差异显著(p=0.023),Dapp与MTRasym(3.5 ppm)的AUC差异显著(p=0.046)。
  • Kapp与病理分级中度相关(|r|=0.724),与Ki-67和HER-2表达轻度相关(|r|=0.454、0.333)。
  • Dapp与病理分级中度相关(|r|=0.648),与Ki-67表达轻度相关(|r|=0.400);MTRasym(3.5 ppm)仅与病理分级轻度相关(|r|=0.468)。

临床应用与阅片要点

  • DKI参数Kapp和Dapp在鉴别乳腺良恶性病变方面可能优于APTWI参数MTRasym(3.5 ppm)。
  • Kapp、Dapp和MTRasym(3.5 ppm)可为乳腺病变组织微观结构表征提供有效参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the value of amide proton transfer-weighted imaging (APTWI) and diffusion kurtosis imaging (DKI) in differentiating benign and malignant breast lesions and analyze the correlations between the derived parameters and prognostic factors of breast cancer.

METHODS: One hundred thirty-five women underwent breast APTWI and DKI. The magnetization transfer ratio asymmetry (MTRasym (3.5 ppm)), apparent kurtosis coefficient (Kapp), and non-Gaussian diffusion coefficient (Dapp) were calculated according to the histological subtype, grade, and prognostic factors (Ki-67, estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor-2 (HER-2), lymph node metastasis, and maximum lesion diameter). The differences, efficacy, and correlation between the parameters were determined.

RESULTS: The Kapp value was higher and the Dapp and MTRasym (3.5 ppm) values were lower in the malignant group than in the benign group (all p < 0.001; AUC (Kapp) = 0.913, AUC (Dapp) = 0.910, and AUC (MTRasym (3.5 ppm)) = 0.796). The differences in the AUC between Kapp and MTRasym (3.5 ppm) and between Dapp and MTRasym (3.5 ppm) were significant (p = 0.023, 0.046). Kapp was moderately correlated with the pathological grade (|r| = 0.724) and mildly correlated with Ki-67 and HER-2 expression (|r| = 0.454, 0.333). Dapp was moderately correlated with the pathological grade (|r| = 0.648) and mildly correlated with Ki-67 expression (|r| = 0.400). MTRasym (3.5 ppm) was only mildly correlated with the pathological grade (|r| = 0.468).

CONCLUSION: DKI is superior to APTWI in differentiating between benign and malignant breast lesions. Each parameter is correlated with some prognostic factors to a certain extent.

KEY POINTS: • DKI and APTWI provide valuable information regarding lesion characterization. • Kapp, Dapp, and MTRasym (3.5 ppm) are valid parameters for the characterization of tissue microstructure. • DKI is superior to APTWI in the study of breast cancer.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Meng N, Wang X, Sun J, et al. A comparative study of the value of amide proton transfer-weighted imaging and diffusion kurtosis imaging in the diagnosis and evaluation of breast cancer. Eur Radiol. 2020. PMID: 32888071. doi:10.1007/s00330-020-07169-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。