文献速递乳腺技术与安全MR

改善乳腺癌DWI图像质量:多激发DWI与常规单激发回波平面成像DWI的比较

Improving the image quality of DWI in breast cancer: comparison of multi-shot DWI using multiplexed sensitivity encoding to conventional single-shot echo-planar imaging DWI.
PubMed 文献 · Br J Radiol · 2020-09-09

该研究纳入20例病理确诊乳腺癌女性患者,比较单激发回波平面成像DWI(ss-EPI-DWI)与多路复用敏感度编码DWI(MUSE-DWI)的图像质量。体模中两种DWI的ADC变异系数低(<2%);患者中MUSE-DWI在恶性病变的ADC值显著低于ss-EPI,但nADC值无显著差异。MUSE-DWI的模糊和失真较ss-EPI-DWI显著改善,定性图像质量提高,作者认为MUSE改善了乳腺DWI的图像质量。

要点

  • MUSE-DWI在乳腺癌中较ss-EPI-DWI显著减少模糊和失真,定性图像质量提高。
  • 恶性病变MUSE-DWI的ADC值显著低于ss-EPI-DWI,但nADC值两者无显著差异。
  • 体模中ss-EPI-DWI与所有MUSE-DWI排列的ADC变异系数均<2%。

核心结论

  • MUSE较ss-EPI改善了乳腺DWI的图像质量;MUSE-DWI在乳腺癌中具有更优的图像质量并减少了模糊和失真。

研究设计与样本

  • 比较性研究,纳入20例病理确诊乳腺癌女性(年龄51±12岁),行ss-EPI-DWI和MUSE-DWI成像,并采用乳腺体模比较6种不同并行加速因子和激发次数的MUSE-DWI排列。
  • 以ADC、标准化ADC(nADC)、模糊和失真指标及定性图像质量评分进行比较;模糊和失真分别采用Crété-Roffet和Mattes互信息指标评估。
  • 体模中ADC和nADC差异用变异系数比较,患者中用配对t检验;模糊、失真和定性指标用Wilcoxon符号秩检验。

关键影像表现/征象

  • 体模中ss-EPI-DWI与所有MUSE-DWI排列之间的ADC变异系数<2%。
  • 20例患者共发现22个恶性病变和3个良性病变。
  • MUSE-DWI的模糊和失真随激发次数和加速因子增加而改善,在患者中MUSE-DWI较ss-EPI-DWI显著改善(模糊P<0.001,失真P=0.002)。
  • 定性图像质量使用MUSE-DWI时提高。

诊断标准与关键数值

  • 恶性病变中MUSE-DWI测量的ADC值显著低于ss-EPI-DWI(P<0.001),良性病变中两者ADC值无显著差异(P=0.21)。
  • 恶性病变和良性病变中nADC值在MUSE-DWI与ss-EPI-DWI之间均无显著差异(P=0.62,P=0.28)。
  • 体模中ss-EPI-DWI与所有MUSE-DWI排列的ADC变异系数<2%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare diffusion-weighted images (DWI) acquired using single-shot echo-planar imaging (ss-EPI) and multiplexed sensitivity encoding (MUSE) in breast cancer.

METHODS: 20 females with pathologically confirmed breast cancer (age 51 ± 12 years) were imaged with ss-EPI-DWI and MUSE-DWI. ADC, normalised ADC (nADC), blur and distortion metrics and qualitative image quality scores were compared. The Crété-Roffet and Mattes mutual information metrics were used to evaluate blurring and distortion, respectively. In a breast phantom, six permutations of MUSE-DWI with varying parallel acceleration factor and number of shots were compared. Differences in ADC and nADC were compared using the coefficient of variation in the phantom and a paired t-test in patients. Differences in blur, distortion and qualitative metrics were analysed using a Wilcoxon signed-rank test.

RESULTS: There was a low coefficient of variation (<2%) in ADC between ss-EPI-DWI and all MUSE-DWI permutations acquired using the phantom. 22 malignant and three benign lesions were identified in 20 patients. ADC values measured using MUSE were significantly lower compared to ss-EPI for malignant but not benign lesions (p < 0.001, p = 0.21). nADC values were not significantly different (p = 0.62, p = 0.28). Blurring and distortion improved with number of shots and acceleration factor, and significantly improved with MUSE in patients (p < 0.001, p = 0.002). Qualitatively, image quality improved using MUSE.

CONCLUSION: MUSE improves the image quality of breast DWI compared to ss-EPI.

ADVANCES IN KNOWLEDGE: MUSE-DWI has superior image quality and reduced blurring and distortion compared to ss-EPI-DWI in breast cancer.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Baxter GC, Patterson AJ, Woitek R, et al. Improving the image quality of DWI in breast cancer: comparison of multi-shot DWI using multiplexed sensitivity encoding to conventional single-shot echo-planar imaging DWI. Br J Radiol. 2020. PMID: 32903028. doi:10.1259/bjr.20200427

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。