文献速递乳腺乳腺X线

随机对照试验中数字乳腺断层合成与数字乳腺摄影按自动乳腺密度分层的筛查结局比较:To-Be试验结果

Comparing Screening Outcomes for Digital Breast Tomosynthesis and Digital Mammography by Automated Breast Density in a Randomized Controlled Trial: Results from the To-Be Trial.
PubMed 文献 · Radiology · 2020-09-15

To-Be随机对照试验在挪威卑尔根比较数字乳腺断层合成联合合成二维乳腺摄影(DBT+SM)与数字乳腺摄影(DM)的筛查结局,按自动密度分级(VDG 1-4)分层分析。共纳入28749名女性,DBT+SM组14380名、DM组14369名。DBT+SM组在VDG 1和VDG 2的召回率低于DM组;DBT+SM组调整后召回及筛查检出乳腺癌的相对风险随VDG升高而增加,DM组未见此差异。

要点

  • DBT+SM组VDG 1召回率2.1%(81/3929)低于DM组3.3%(106/3212),P=0.001。
  • DBT+SM组VDG 2召回率3.2%(200/6216)低于DM组4.3%(267/6280),P=0.002。
  • DBT+SM组调整后召回相对风险随VDG升高:VDG 2为1.8、VDG 3为2.4、VDG 4为1.8,DM组无此差异。

诊断标准与关键数值

  • 召回率:DBT+SM组VDG 1为2.1%(81/3929),DM组VDG 1为3.3%(106/3212),P=0.001。
  • 召回率:DBT+SM组VDG 2为3.2%(200/6216),DM组VDG 2为4.3%(267/6280),P=0.002。
  • DBT+SM组调整后召回相对风险:VDG 2为1.8(P<0.001)、VDG 3为2.4(P<0.001)、VDG 4为1.8(P=0.02)。
  • DBT+SM组调整后筛查检出乳腺癌相对风险:VDG 2为2.4(P=0.004)、VDG 3为2.8(P=0.01)、VDG 4为2.8(P=0.05)。
  • DM组调整后召回相对风险:VDG 2为1.3(P=0.06)、VDG 3为1.1(P=0.41)、VDG 4为1.1(P=0.71);筛查检出乳腺癌相对风险:VDG 2为1.7(P=0.13)、VDG 3为2.1(P=0.06)、VDG 4为2.2(P=0.15)。

临床应用与阅片要点

  • 原文结论指出DBT+SM与DM相比在VDG 1和VDG 2女性中召回率更低。
  • 原文结论指出DBT+SM组调整后召回及筛查检出乳腺癌的相对风险随乳腺密度升高而增加,DM组未见此变化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Digital breast tomosynthesis (DBT) is considered superior to digital mammography (DM) for women with dense breasts. Purpose To identify differences in screening outcomes, including rates of recall, false-positive (FP) findings, biopsy, cancer detection rate, positive predictive value of recalls and biopsies, and histopathologic tumor characteristics by density using DBT combined with two-dimensional synthetic mammography (SM) (hereafter, DBT+SM) versus DM. Materials and Methods This randomized controlled trial comparing DBT+SM and DM was performed in Bergen as part of BreastScreen Norway, 2016-2017. Automated software measured density (Volpara Density Grade [VDG], 1-4). The outcomes were compared for DBT+SM versus DM by VDG in descriptive analyses. A stratified log-binomial regression model was used to estimate relative risk of outcomes in subgroups by screening technique. Results Data included 28 749 women, 14 380 of whom were screened with DBT+SM and 14 369 of whom were screened with DM (both groups: median age, 59 years; interquartile range [IQR], 54-64 years). The recall rate was lower for women screened with DBT+SM versus those screened with DM for VDG 1 (2.1% [81 of 3929] vs 3.3% [106 of 3212]; P = .001) and VDG 2 (3.2% [200 of 6216] vs 4.3% [267 of 6280]; P = .002). For DBT+SM, adjusted relative risk of recall (VDG 2: 1.8; P < .001; VDG 3: 2.4; P < .001; VDG 4: 1.8; P = .02) and screen-detected breast cancer (VDG 2: 2.4; P = .004; VDG 3: 2.8; P = .01; VDG 4: 2.8; P = .05) increased with VDG, whereas no differences were observed for DM (relative risk of recall for VDG 2: 1.3; P = .06; VDG 3: 1.1; P = .41; VDG 4: 1.1; P = .71; and relative risk of screen-detected breast cancer for VDG 2: 1.7; P = .13; VDG 3: 2.1; P = .06; VDG 4: 2.2; P = .15). Conclusion Screening with digital breast tomosynthesis combined with synthetic two-dimensional mammograms (DBT+SM) versus digital mammography (DM) yielded lower recall rates for women with Volpara Density Grade (VDG) 1 and VDG 2. Adjusted relative risk of recall and screen-detected breast cancer increased with denser breasts for DBT+SM but not for DM. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Sechopoulos and Athanasiou in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Moshina N, Aase HS, Danielsen AS, et al. Comparing Screening Outcomes for Digital Breast Tomosynthesis and Digital Mammography by Automated Breast Density in a Randomized Controlled Trial: Results from the To-Be Trial. Radiology. 2020. PMID: 32930649. doi:10.1148/radiol.2020201150

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。