文献速递乳腺US

罕见乳腺癌在应变弹性成像假阴性结果中的作用

The role of rare breast cancers in the false negative strain elastography results.
PubMed 文献 · Radiol Med · 2020-09-07

研究纳入BI-RADS 5类并行应变弹性成像及粗针活检的浸润性乳腺癌患者,比较罕见乳腺癌与常见浸润性乳腺癌的应变比值。罕见乳腺癌的应变比值显著低于其他乳腺癌(p=0.012),是弹性成像假阴性的重要原因,结果应结合灰阶超声解读。

要点

  • 罕见乳腺癌应变比值显著低于常见浸润性乳腺癌,是弹性成像假阴性的重要原因。
  • 肿瘤大小、距皮肤距离及组织学分级与假阴性结果无显著统计学差异。

核心结论

  • 罕见乳腺癌是浸润性乳腺癌弹性成像评估中出现假阴性的重要原因,弹性成像结果应结合灰阶超声表现综合解读。

研究设计与样本

  • 研究纳入BI-RADS 5类并行应变弹性成像及粗针活检的浸润性乳腺癌患者,每例罕见乳腺癌匹配4例常见浸润性乳腺癌作为对照组。
  • 共113例为真阳性(70.6%),47例为假阴性(29.4%)。
  • 应变比值截断值设为2.3,采用Pearson卡方检验和Fisher精确检验进行统计分析,P值<0.05认为有统计学意义。

诊断标准与关键数值

  • 应变比值截断值为2.3,用于区分真阳性与假阴性组。
  • 罕见乳腺癌的应变比值显著低于其他乳腺癌(p=0.012)。
  • 肿瘤大小、病灶距皮肤距离及肿瘤分级在真阳性组与假阴性组间无统计学显著差异(p>0.05)。

临床应用与阅片要点

  • 对BI-RADS 5类病灶行应变弹性成像时,需注意罕见乳腺癌可能表现为应变比值较低而呈假阴性。
  • 弹性成像结果应结合灰阶超声表现综合解读,避免因假阴性而低估恶性风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Elastography was primarily used as an adjunctive method along with ultrasonography in differentiation between benign from malignant lesions. Occasionally, overlaps can occur which are caused by some rare invasive breast cancers. Our aim is to analyze the role of rare breast cancers in false negative strain elastography results and to assess the relation among false negative results and tumor size, lesion distance to skin, and tumor grade.

METHODS: Patients with BI-RADS 5 category underwent strain elastography and core biopsy. All those with confirmed invasive breast cancer were included. For each rare breast cancer, four usual invasive breast cancer cases were taken as a control group. The cut-off value of strain ratio was considered as 2.3. The true positive and the false negative groups were compared in terms of histological type (rare carcinomas and the others) and the other parameters. Pearson Chi-square and Fisher's exact test were used for statistical analyses. P values < 0.05 were considered statistically significant.

RESULTS: One hundred-thirteen patients were defined as true positive (70.6%), and 47 patients were defined as false negative (29.4%). Strain ratio values of the rare breast cancers were significantly lower than those of the other breast cancers (p = 0.012). There was no statistically significant difference between the groups with respect to tumor size, distance to skin, and tumor grade (p > 0.05).

CONCLUSION: The rare breast cancers are an important cause of false negativity in elastographic evaluation of invasive breast cancers. The results should be interpreted in combination with grayscale US findings.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Sezgin G, Coskun M, Apaydin M, et al. The role of rare breast cancers in the false negative strain elastography results. Radiol Med. 2020. PMID: 32894448. doi:10.1007/s11547-020-01270-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。