剪切波弹性成像引导的空心针活检用于确定乳腺癌分子亚型
这项随机前瞻性对照队列研究纳入58例乳腺病灶患者,比较无SWE引导活检(A组)、SWE引导下较硬区域活检(B组)和较软区域活检(C组)与手术病理的一致性。B组敏感度、良恶性一致率、诊断一致率及免疫组化亚型一致率均达100%,ER一致率亦最高。
要点
- SWE引导下对病灶较硬区域行空心针活检,诊断一致率与免疫组化亚型一致率均达100%。
- 无SWE引导活检的敏感度为96.7%,诊断一致率为89.5%,亚型一致率为71.4%。
- SWE引导下较软区域活检的亚型一致率与无引导活检相同,均为71.4%。
诊断标准与关键数值
- 活检A(无SWE引导,30个病灶)敏感度96.7%,良恶性一致率94.7%,诊断一致率89.5%,免疫组化亚型一致率71.4%。
- 活检B(SWE引导取较硬区域,30个病灶)敏感度100%,良恶性一致率100%,诊断一致率100%,免疫组化亚型一致率100%。
- 活检C(SWE引导取较软区域,30个病灶)敏感度100%,良恶性一致率90%,诊断一致率90%,免疫组化亚型一致率71.4%。
- 以ER、PR、Ki67率10%差异为显著时,ER一致率在活检B最高(77.8%,p=0.040)。
- 免疫组化亚型一致率活检B为100%,活检A与C均为71.4%(p=0.086)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate whether shear-wave elastography (SWE) guidance during core-needle biopsy can improve diagnostic accuracy and accurate determination of the molecular subtypes of breast cancer.
METHODS: This controlled, randomized prospective cohort study included 58 patients (mean age: 56.9 ± 16.2) who were referred for image-guided core-needle biopsy between May 2018 and April 2019 for lesions larger than 1 cm. In Group 1, 30 lesions were biopsied without SWE guidance and recorded as Biopsy A. In Group 2, 30 lesions were examined with SWE before biopsy, and then two different parts of the lesions were biopsied; biopsies from the relatively rigid areas of the lesions were recorded as Biopsy B, and biopsies from the less rigid areas of the lesions were recorded as Biopsy C. The histopathological and immunohistochemical results of biopsies were compared with the surgical results.
RESULTS: The sensitivity of Biopsy A, B and C were 96.7%, 100% and 100%, respectively. The benign-malignant concordance rates were 94.7%, 100%, and 90% and the diagnostic concordance rates were 89.5%, 100%, and 90% in Biopsies A, B, and C, respectively. When the 10% differences in the estrogen receptor (ER), progesterone receptor (PR), and Ki67 rates were considered significant, the concordance rate of ER was highest in Biopsy B (77.8%; p = 0.040). The concordance rate of immunohistochemical subtyping was 100% in Biopsy B and 71.4% in Biopsies A and C (p = 0.086).
CONCLUSION: SWE-guided core-needle biopsy of breast lesions increased the sensitivity, diagnostic accuracy, and accuracy of immunohistochemical subtyping to 100%.
引用
- Peker A, Balci P, Basara Akin I, et al. Shear-Wave Elastography-Guided Core Needle Biopsy for the Determination of Breast Cancer Molecular Subtype. J Ultrasound Med. 2020. PMID: 32918306. doi:10.1002/jum.15499