亚赫兹黏弹性多参数分析及质量指标用于乳腺肿块鉴别
研究对活检前患者应用亚赫兹黏弹性分析(SAVE),通过超声检测外部斜坡保持应力下的组织位移获取黏弹性参数,并纳入多变量分类框架鉴别病理证实的乳腺良恶性肿块。单独使用全部黏弹性参数准确率71.43%,联合超声特征与病灶大小后82.24%,加用基于单轴运动的质量指标后81.25%,三者联合SAVE后准确率91.3%。
要点
- SAVE单独使用全部黏弹性参数鉴别乳腺肿块准确率为71.43%。
- SAVE联合超声特征与病灶大小后准确率为82.24%。
- SAVE联合超声特征、病灶大小及质量指标后准确率达91.3%。
核心结论
- SAVE可作为稳健的超声诊断工具,单独作为生物标志物或与超声特征联合用于乳腺肿块无创鉴别。
研究设计与样本
- 研究纳入活检前患者,应用SAVE技术,通过超声检测外部斜坡保持应力下的组织反应,以线性标准固体模型估计黏弹性参数。
- 以病理结果作为参考标准鉴别乳腺肿块良恶性。
- 采用多变量分类框架,评估黏弹性参数单独及联合超声特征、病灶大小和质量指标的鉴别效能。
关键影像表现/征象
- 外部斜坡保持应力下,组织表现为快速瞬时响应和缓慢蠕变样变形,据此建模为线性标准固体响应并估计黏弹性参数。
诊断标准与关键数值
- 单独使用全部黏弹性参数时,SAVE鉴别乳腺肿块的准确率为71.43%。
- SAVE联合超声特征和病灶大小时,准确率为82.24%。
- 加用基于单轴运动的质量指标后,准确率为81.25%。
- SAVE联合超声特征、病灶大小和质量指标三者时,准确率为91.3%。
临床应用与阅片要点
- SAVE可作为独立生物标志物或与超声特征联合,用于活检前乳腺肿块的无创鉴别诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
We applied sub-Hertz analysis of viscoelasticity (SAVE) to differentiate breast masses in pre-biopsy patients. Tissue response during external ramp-and-hold stress was ultrasonically detected. Displacements were used to acquire tissue viscoelastic parameters. The fast instantaneous response and slow creep-like deformations were modeled as the response of a linear standard solid from which viscoelastic parameters were estimated. These parameters were used in a multi-variable classification framework to differentiate malignant from benign masses identified by pathology. When employing all viscoelasticity parameters, SAVE resulted in 71.43% accuracy in differentiating lesions. When combined with ultrasound features and lesion size, accuracy was 82.24%. Adding a quality metric based on uniaxial motion increased the accuracy to 81.25%. When all three were combined with SAVE, accuracy was 91.3%. These results confirm the utility of SAVE as a robust ultrasound-based diagnostic tool for non-invasive differentiation of breast masses when used as stand-alone biomarkers or in conjunction with ultrasonic features.
引用
- Bayat M, Nabavizadeh A, Nayak R, et al. Multi-parameter Sub-Hertz Analysis of Viscoelasticity With a Quality Metric for Differentiation of Breast Masses. Ultrasound Med Biol. 2020. PMID: 32917470. doi:10.1016/j.ultrasmedbio.2020.08.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。