文献速递妇产影像泌尿生殖MR

原发肿瘤的定量动力学参数可用于预测早期宫颈癌盆腔淋巴结转移

Quantitative kinetic parameters of primary tumor can be used to predict pelvic lymph node metastasis in early-stage cervical cancer.
PubMed 文献 · Abdom Radiol (NY) · 2020-09-15

研究纳入66例新诊断FIGO IB-IIA期宫颈癌患者,术前行DCE-MRI获取原发肿瘤动力学参数,比较有无盆腔淋巴结转移(PLNM)患者的参数差异。结果显示Kep和淋巴结短径是PLNM的独立预测因子,两者联合AUC最高为0.839;以1.113 min-1为阈值,Kep预测正常大小淋巴结患者PLNM的敏感度和特异度分别为0.909和0.667。

要点

  • Kep和淋巴结短径是早期宫颈癌盆腔淋巴结转移的独立预测因子。
  • Kep联合淋巴结短径预测PLNM的AUC最高,为0.839。
  • 以1.113 min-1为阈值,Kep预测正常大小淋巴结患者PLNM的敏感度0.909、特异度0.667。

核心结论

  • 原发肿瘤的Kep可作为替代标志物预测宫颈癌盆腔淋巴结转移。

研究设计与样本

  • 回顾性纳入2017年7月至2019年8月间66例新诊断宫颈癌女性,均为FIGO IB-IIA期并接受子宫切除术和双侧淋巴结清扫术。
  • 从DCE-MRI数据中提取原发肿瘤动力学参数,比较有无PLNM患者的肿瘤直径、ADC值、动力学参数及淋巴结短轴直径。
  • 采用逻辑回归分析确定PLNM的独立预测因子,并用受试者工作特征曲线评估预测性能。

诊断标准与关键数值

  • PLNM组20例、无PLNM组46例;PLNM组肿瘤直径、Kep和淋巴结短轴直径显著更高(P < 0.01)。
  • 多因素逻辑回归显示Kep和淋巴结短轴直径为PLNM的独立预测因子。
  • Kep联合淋巴结短轴直径的AUC最高,为0.839。
  • 联合Kep后,淋巴结短轴直径的敏感度、特异度、阴性预测值和阳性预测值分别从0.500、0.957、0.815、0.833提高至0.600、0.978、0.923、0.849。
  • 以1.113 min-1为阈值,Kep预测正常大小淋巴结患者PLNM的敏感度和特异度分别为0.909和0.667。

临床应用与阅片要点

  • 作者认为原发肿瘤Kep可作为预测宫颈癌PLNM的替代标志物,联合淋巴结短轴直径可提高预测性能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the role of kinetic parameters of primary tumor derived from dynamic contrast-enhanced MRI (DCE-MRI) in predicting pelvic lymph node metastasis (PLNM) in patients with cervical cancer.

METHODS: 66 women with newly diagnosed cervical cancer were included between July 2017 and August 2019. All patients had a FIGO stage IB-IIA cancer and treated with hysterectomy and bilateral lymphadenectomy. Kinetic parameters of the primary tumor were derived from DCE-MRI data. The tumor diameter, ADC value, kinetic parameters, and nodal short-axis diameter were compared between patients with or without PLNM. Logistic regression analysis was used to determine the independent predictors for PLNM and receiver operator characteristic curve was used to evaluate the predictive performance.

RESULTS: There were 20 patients with PLNM and 46 patients without PLNM. Tumor diameter, the efflux rate constant (Kep), and nodal short-axis diameter were significantly higher in patients with PLNM (P < 0.01). Multivariate logistic regression analysis showed that Kep and short-axis diameter were independent predictors for PLNM. Combining Kep and nodal short-axis diameter yielded the highest area under the curve (AUC) of 0.839. Combined with Kep, the sensitivity, specificity, negative predictive value, and positive predictive value of nodal short-axis diameter increased from 0.500, 0.957, 0.815, and 0.833 to 0.600, 0.978, 0.923, and 0.849, respectively. With 1.113 min-1 as threshold, the sensitivity and specificity values of Kep in predicting PLNM in patients with normal-sized lymph nodes were 0.909 and 0.667, respectively.

CONCLUSIONS: Kep of primary tumor can be used as a surrogate marker to predict PLNM in cervical cancer.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Bai Z, Shi J, Yang Z, et al. Quantitative kinetic parameters of primary tumor can be used to predict pelvic lymph node metastasis in early-stage cervical cancer. Abdom Radiol (NY). 2020. PMID: 32930831. doi:10.1007/s00261-020-02762-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。