暗色皮质环:多囊卵巢综合征的MRI特征
回顾性研究纳入52例PCOS患者共98个卵巢与52名年龄匹配对照共104个卵巢,评估T2加权序列上卵巢周围暗色皮质环。PCOS组连续皮质环比例71%、无环8%,对照组分别为25%和37%(p<0.001);连续皮质环诊断PCOS的敏感度和特异度分别为71%和75%,皮质环厚度联合连续性诊断PCOS的AUC为0.77,与常规卵巢体积联合卵泡计数相近。作者认为卵巢暗色皮质环可作为支持PCOS诊断的MRI特征。
要点
- T2加权序列上卵巢周围暗色皮质环覆盖≥50%周径为存在,>75%为连续、50-75%为不连续、<50%为无。
- PCOS组连续皮质环比例71% vs 对照组25%,无皮质环比例8% vs 37%(p<0.001)。
- 连续皮质环诊断PCOS敏感度71%、特异度75%;皮质环厚度联合连续性AUC为0.77。
核心结论
- 卵巢周围暗色皮质环是可用于支持PCOS诊断的MRI特征。
- 连续皮质环诊断PCOS的敏感度和特异度分别为71%和75%,皮质环厚度联合连续性的AUC为0.77,与卵巢体积联合卵泡计数相近。
研究设计与样本
- 回顾性研究,纳入52例PCOS患者共98个卵巢和52名年龄匹配对照共104个卵巢。
- 在至少两个正交视图的T2加权序列上评估卵巢,测量卵巢体积和每卵巢卵泡计数。
- 暗色皮质环定义为T2加权成像上覆盖卵巢周径≥50%;连续性分级:连续为>75%周径、不连续为50-75%周径、无环为<50%周径,存在时测量厚度。
- 采用t检验和χ2检验比较连续变量和分类变量,ROC曲线及AUC评估预测性能,DeLong配对检验比较AUC。
关键影像表现/征象
- PCOS患者中连续皮质环比例71%,无皮质环比例8%;对照组分别为25%和37%(p<0.001)。
- PCOS组平均皮质环厚度1.4 mm,对照组0.8 mm(p<0.001)。
- 皮质环厚度与连续皮质环存在强相关。
诊断标准与关键数值
- 连续皮质环诊断PCOS的敏感度71%、特异度75%。
- 皮质环厚度1.2 mm诊断PCOS的敏感度75%、特异度60%。
- 皮质环厚度联合连续性诊断PCOS的AUC为0.77,与卵巢体积联合卵泡计数联合应用相似。
临床应用与阅片要点
- 阅片时可在T2加权序列上评估卵巢周围暗色皮质环是否覆盖≥50%周径,并区分连续(>75%)、不连续(50-75%)和无环(<50%)。
- 连续皮质环和皮质环厚度可作为支持PCOS诊断的MRI征象,但敏感度和特异度有限,需结合卵巢体积和卵泡计数等常规特征。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine if the presence of a dark cortical rim around the ovary on magnetic resonance imaging (MRI) is associated with polycystic ovarian syndrome (PCOS).
MATERIALS AND METHODS: This retrospective study included 52 PCOS patients with 98 total ovaries and 52 age-matched controls with 104 total ovaries. The ovaries were evaluated on MRI with at least two orthogonal views on T2-weighted sequences. Ovarian volume and follicular count per ovary were measured. Each ovary was also assessed for a dark cortical rim around the ovary on T2-weighted imaging which involved equal to or more than 50% of the ovarian circumference. The degree of rim continuity was classified as continuous if the rim involved greater than 75% of the ovarian circumference, discontinuous if 50-75% of the ovarian circumference was covered, or absent if less than 50% of the ovarian circumference was involved. The rim thickness was measured if present. T test and χ2 tests were performed to compare continuous and categorical variables, correspondingly, between cases and controls. ROC curves and area under the curve (AUC) were used to assess predictive performance and DeLong's paired test was used to compare AUCs.
RESULTS: A higher percentage of PCOS patients exhibited a continuous cortical rim about the ovary (71%) and a lower percentage of an absent cortical rim (8%) compared to controls (25% and 37%, respectively) (p < 0.001). A continuous cortical ovarian rim has a sensitivity and specificity of 71% and 75%, respectively, for diagnosing PCOS. Mean cortical rim thickness is significantly higher in the PCOS group (1.4 mm) compared with controls (0.8 mm) (p < 0.001). Cortical rim thickness and presence of a continuous cortical rim are strongly correlated. Cortical rim thickness of 1.2 mm provides a sensitivity and specificity of 75% and 60%, correspondingly, for a diagnosis of PCOS. Cortical rim thickness combined with cortical rim continuity has an AUC of 0.77 for diagnosing PCOS, which is similar to conventional imaging features of ovarian volume and follicular count combined.
CONCLUSION: A dark cortical rim around the ovary is an MRI feature that can be used to support a diagnosis of PCOS.
引用
- Badeeb A, Brook A, Lee KS, et al. Dark cortical rim: an MRI feature of polycystic ovarian syndrome. Abdom Radiol (NY). 2020. PMID: 32948912. doi:10.1007/s00261-020-02749-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。