文献速递泌尿生殖腹部MR

低级别移行区前列腺癌的细胞密度:限制弥散受限与肿瘤侵袭性相关性的因素

Cellular density of low-grade transition zone prostate cancer: A limiting factor to correlate restricted diffusion with tumor aggressiveness.
PubMed 文献 · Eur J Radiol · 2020-08-20

本研究比较了Gleason评分3+3的移行区前列腺癌(TZ-PCa)与外周区前列腺癌(PZ-PCa)的平均表观弥散系数(ADCmean)和腺体密度,发现TZ-PCa的ADCmean显著低于PZ-PCa,且与更高的腺体密度相关,TZ-PCa的ADCmean与更高级别前列腺癌无显著差异,提示细胞密度是限制弥散受限与肿瘤侵袭性相关性的因素。

要点

  • Gleason评分3+3的移行区前列腺癌ADCmean显著低于外周区,与更高腺体密度相关。
  • 移行区Gleason评分3+3前列腺癌的ADCmean与Gleason评分3+4或>3+4无显著差异。
  • 外周区Gleason评分3+3前列腺癌ADCmean高于Gleason评分>3+4,与3+4无显著差异。

诊断标准与关键数值

  • Gleason评分3+3肿瘤的ADCmean在移行区为728×10⁻⁶±52 mm²/s(范围670-1060 mm²/s),在外周区为865×10⁻⁶±121 mm²/s(范围670-1120 mm²/s),移行区显著低于外周区(p=0.0007)。
  • 腺体密度涉及超过50%肿瘤区域者在移行区Gleason评分3+3前列腺癌中占58%(7/12),在外周区前列腺癌中占7.6%(1/13),差异显著(p=0.03)。
  • 移行区Gleason评分3+3前列腺癌的ADCmean与Gleason评分3+4(p=0.14)或Gleason评分>3+4(p=0.9)无显著差异,无论起源区域。
  • 在外周区,Gleason评分3+3前列腺癌的ADCmean高于Gleason评分>3+4外周区前列腺癌(p=0.02),与Gleason评分3+4外周区前列腺癌相似(p=0.24)。
  • ADCmean与Gleason评分的相关性在移行区前列腺癌中较弱(ρ=0.32;p=0.04),在外周区前列腺癌中为中等(ρ=0.45;p=0.003)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the mean apparent diffusion coefficient (ADCmean) and glandular density of Gleason score (GS) 3 + 3 transition zone prostate cancers (TZ-PCa) with those of the peripheral zone (PZ-PCa).

MATERIAL & METHODS: Seventy-nine men (mean age: 65 ± 6 [SD] years; range: 52-81 years) with 37 TZ-PCa (37/79; 53 %) and 42 PZ-PCa (42/79; 47 %) had prostate MRI before radical prostatectomy. Glandular cell density was semi-quantitatively evaluated in all tumors. ADCmean and glandular cell density of GS3 + 3 TZ-PCa were compared to those of PZ-PCa. ADCmean was correlated to GS in each zone.

RESULTS: ADCmean of GS 3 + 3 tumors was significantly lower in the TZ (728 × 10-6±52 [SD] mm²/s; range: 670-1060mm²/s) than in the PZ (865 × 10-6 ±121 [SD] mm²/s; range: 670-1120mm²/s) (p = 0.0007), related to a significantly higher glandular density involving more than 50 % of the tumor in 58 % (7/12) of patients in GS3 + 3 TZ-PCa versus 7.6 % (1/13) in PZ-PCa (p = 0.03). ADCmean of GS3 + 3 TZ-PCa was not significantly different from that of GS 3 + 4 (p = 0.14) or GS>3 + 4 Ca (p = 0.9), whatever the zone of origin. In the PZ, ADCmean of GS 3 + 3-PCa was higher than that of Gleason>3 + 4 PZ-PCa (p = 0.02) and similar to that of GS 3 + 4 PZ-PCa (p = 0.24). Correlation between ADCmean and GS was weak for TZ-PCa (ρ = 0.32; p = 0.04) and moderate for PZ-PCa (ρ = 0.45; p = 0.003).

CONCLUSION: ADCmean of GS 3 + 3 TZ-PCa is significantly lower than that of GS 3 + 3 PZ-PCa, related to a unique dense histological pattern and reaches that of higher-grade PCa, whatever the zone of origin.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Barral M, Jemal-Turki A, Beuvon F, et al. Cellular density of low-grade transition zone prostate cancer: A limiting factor to correlate restricted diffusion with tumor aggressiveness. Eur J Radiol. 2020. PMID: 32866908. doi:10.1016/j.ejrad.2020.109230

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。