文献速递泌尿生殖MR

扩散峰度成像参数与单指数ADC在前列腺癌临床显著癌判定中的诊断效能比较

Comparison of diagnostic performance between diffusion kurtosis imaging parameters and mono-exponential ADC for determination of clinically significant cancer in patients with prostate cancer.
PubMed 文献 · Abdom Radiol (NY) · 2020-09-23

本研究纳入92例经组织学证实的前列腺癌患者,均行3T-MRI包括DWI(b值0、100、1000、2000s/mm²),比较DKI参数(Dapp、Kapp)与单指数ADC判定临床显著癌(GS≥7)的诊断效能。结果显示Kapp的AUC为0.707,与单指数ADC的0.725及Dapp的0.726均无显著差异,DKI参数诊断效能与单指数ADC相当。

要点

  • Kapp鉴别临床显著癌的AUC为0.707,与单指数ADC的0.725无显著差异(P=0.2175)。
  • Kapp最大准确度78%、敏感度86%、特异度47%,单指数ADC分别为75%、81%、53%。
  • DKI参数对前列腺癌临床显著癌的判定效能与单指数ADC相当。

诊断标准与关键数值

  • Kapp鉴别临床显著癌(GS≥7)与非临床显著癌的AUC为0.707(95%CI 0.603-0.798)。
  • 单指数ADC的AUC为0.725(95%CI 0.622-0.813),与Kapp比较P=0.2175。
  • Dapp的AUC为0.726(95%CI 0.623-0.814),与Kapp比较P=0.9628。
  • Kapp最大准确度78%、敏感度86%、特异度47%。
  • 单指数ADC最大准确度75%、敏感度81%、特异度53%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the diagnostic performance between diffusion kurtosis imaging (DKI) parameters and mono-exponential apparent diffusion coefficient (ADC) for determination of clinically significant cancer (CSC, Gleason score (GS) ≥ 7) in patients with histologically proven prostate cancer (PCa).

METHODS: A total of 92 patients (mean age: 71.5 years, range: 47-89 years) who had been diagnosed as PCa and undergone 3 T-MRI including DWI (b values, 0, 100, 1000, 2000s/mm2) were included in this study. The DKI parameters, namely apparent diffusion for non-Gaussian distribution (Dapp) and apparent kurtosis coefficient (Kapp), were calculated by dedicated software using mono-exponential and diffusion kurtosis models for quantitation. The measurement was performed for a whole tumor after segmentation, and pathologic topographic maps or systemic biopsy results served as the reference standard for segmentation. To compare the diagnostic performance of each parameter for determination of CSC, pair-wise comparison of receiver operating characteristic (ROC) curves was performed.

RESULTS: The study population consisted of GS 6 (n = 18), GS 7 (n = 31), GS 8 (n = 25), GS 9 (n = 15) and GS 10 (n = 3) patients. The area under the ROC curve of Kapp (0.707, 95% CI 0.603-0.798) for discriminating CSC from non-CSC was not significantly different from those of mono-exponential ADC (0.725, 0.622-0.813, P = 0.2175) or Dapp (0.726, 0.623-0.814, P = 0.9628). Diagnostic predictive values of Kapp were estimated to a maximum accuracy of 78%, a sensitivity of 86%, and a specificity of 47%, while those of mono-exponential ADC were 75, 81, and 53%, respectively.

CONCLUSION: The DKI parameters showed a diagnostic performance comparable to mono-exponential ADC for determination of CSC in patients with PCa.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。