文献速递泌尿生殖腹部MR

高级放大扩散加权成像与常规全视野扩散加权成像在前列腺癌检测中的比较:一项影像组学特征研究

Advanced zoomed diffusion-weighted imaging vs. full-field-of-view diffusion-weighted imaging in prostate cancer detection: a radiomic features study.
PubMed 文献 · Eur Radiol · 2020-09-16

本研究纳入136例患者(前列腺癌73例、无前列腺癌63例),比较基于高级放大扩散加权成像与常规全视野扩散加权成像的影像组学特征检测前列腺癌的效能。结果显示基于z-DWI技术的影像组学特征诊断准确率优于f-DWI技术,混合模型诊断效能最佳。

要点

  • 基于高级放大DWI的影像组学特征对前列腺癌的诊断准确率优于常规全视野DWI。
  • 在单个成像模态中,基于z-calDWIb2000的影像组学特征诊断效能最佳。
  • 混合模型(mp-MRI+临床独立危险因素)诊断效能最佳,验证集AUC为0.93。

诊断标准与关键数值

  • z-DWIb1500与f-DWIb1500预测性能比较差异有统计学意义(p=0.048);z-calDWIb2000与f-DWIb1500比较差异有统计学意义(p=0.014)。
  • z-ADC的曲线下面积(AUC)略高于f-ADC,但差异无统计学意义(p=0.127)。
  • 临床独立危险因素模型、mp-MRI模型和混合模型预测前列腺癌的AUC在训练集分别为0.81、0.93和0.94,在验证集分别为0.74、0.92和0.93。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We aimed to compare the efficiency of prostate cancer (PCa) detection using a radiomics signature based on advanced zoomed diffusion-weighted imaging and conventional full-field-of-view DWI.

METHODS: A total of 136 patients, including 73 patients with PCa and 63 without PCa, underwent multi-parametric magnetic resonance imaging (mp-MRI). Radiomic features were extracted from prostate lesion areas segmented on full-field-of-view DWI with b-value = 1500 s/mm2 (f-DWIb1500), advanced zoomed DWI images with b-value = 1500 s/mm2 (z-DWIb1500), calculated zoomed DWI with b-value = 2000 s/mm2 (z-calDWIb2000), and apparent diffusion coefficient (ADC) maps derived from both sequences (f-ADC and z-ADC). Single-imaging modality radiomics signature, mp-MRI radiomics signature, and a mixed model based on mp-MRI and clinically independent risk factors were built to predict PCa probability. The diagnostic efficacy and the potential net benefits of each model were evaluated.

RESULTS: Both z-DWIb1500 and z-calDWIb2000 had significantly better predictive performance than f-DWIb1500 (z-DWIb1500 vs. f-DWIb1500: p = 0.048; z-calDWIb2000 vs. f-DWIb1500: p = 0.014). z-ADC had a slightly higher area under the curve (AUC) value compared with f-ADC value but was not significantly different (p = 0.127). For predicting the presence of PCa, the AUCs of clinical independent risk factors model, mp-MRI model, and mixed model were 0.81, 0.93, and 0.94 in training sets, and 0.74, 0.92, and 0.93 in validation sets, respectively.

CONCLUSION: Radiomics signatures based on the z-DWI technology had better diagnostic accuracy for PCa than that based on the f-DWI technology. The mixed model was better at diagnosing PCa and guiding clinical interventions for patients with suspected PCa compared with mp-MRI signatures and clinically independent risk factors.

KEY POINTS: • Advanced zoomed DWI technology can improve the diagnostic accuracy of radiomics signatures for PCa. • Radiomics signatures based on z-calDWIb2000 have the best diagnostic performance among individual imaging modalities. • Compared with the independent clinical risk factors and the mp-MRI model, the mixed model has the best diagnostic efficiency.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Hu L, Zhou DW, Fu CX, et al. Advanced zoomed diffusion-weighted imaging vs. full-field-of-view diffusion-weighted imaging in prostate cancer detection: a radiomic features study. Eur Radiol. 2020. PMID: 32935192. doi:10.1007/s00330-020-07227-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。