应用实时声触诊弹性成像监测移植肾弹性的变化
31例肾移植后肾功能不全患者行超声引导下穿刺活检,采用常规超声与声触诊弹性成像(STE)测量肾皮质最大弹性模量(Emax),并按病理结果比较四种并发症(药物性肾损伤、急性排斥、慢性移植肾肾病、BK病毒肾病)间Emax的差异及对肾纤维化/肾小管萎缩严重程度的评估价值。
要点
- 移植肾四种并发症的皮质Emax存在统计学差异(p<0.05),排序为BK病毒肾病>慢性移植肾肾病>急性排斥>药物性肾损伤。
- 肾皮质Emax在肾纤维化与肾小管萎缩不同严重程度间有统计学差异(p<0.05),可用于评估其严重程度。
- STE测得的Emax可作为移植肾并发症及纤维化/萎缩程度的辅助评估指标。
核心结论
- 四种移植肾并发症对肾皮质Emax的影响各不相同,Emax可用于评估肾纤维化和肾小管萎缩的严重程度。
研究设计与样本
- 共纳入31例肾移植后肾功能不全患者,行超声引导下穿刺活检病理检查,同时行常规超声与声触诊弹性成像(STE)检查。
关键影像表现/征象
- 移植肾四种并发症的肾皮质Emax大小排序为BK病毒肾病>慢性移植肾肾病>急性排斥>药物性肾损伤。
诊断标准与关键数值
- 以病理结果为参照,采用受试者工作特征(ROC)曲线比较STE的诊断效能。
- 肾皮质Emax在四种并发症间有统计学差异(p<0.05),在肾纤维化及肾小管萎缩严重程度间也有统计学差异(p<0.05)。
临床应用与阅片要点
- 测量移植肾皮质Emax时需结合病理结果解读,不同并发症的Emax分布不同,BK病毒肾病最高、药物性肾损伤最低。
- Emax可辅助评估肾纤维化与肾小管萎缩的严重程度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To use sound touch elastography (STE) to assess the changes of renal cortex among different complications following renal transplantation.
MATERIALS AND METHODS: A total of 31 patients with renal dysfunction after renal transplantation underwent an ultrasound-guided biopsy for pathological examination with conventional and STE ultrasound. The maximum elastic modulus (Emax) was determined, and the biopsy specimen was evaluated for evidence of significant differences among four different complications: drug-induced renal damage, acute rejection, chronic allograft nephropathy (CAN), and BK virus (BKV) nephropathy. Receiver operator characteristics were used to compare the diagnostic efficacy of STE ultrasound according to the pathological results.
RESULTS: The quantitative index Emax of the STE technique was statistically significant among the four different complications (p<0.05). The distribution of the magnitude of Emax in the renal cortex was BKV nephropathy > CAN > acute rejection > drug induced renal damage. The renal cortex Emax was statistically different for the severity of renal fibrosis and tubular atrophy (p<0.05).
CONCLUSION: Each of the four different complications of transplantation influenced the Emax of the renal cortex differently. Emax can be used to assess the severity of renal fibrosis and tubular atrophy.