文献速递泌尿生殖MR

主动监测期间系列MRI上的前列腺癌测量:是时候采用PRECISE了

Prostate cancer measurements on serial MRI during active surveillance: it's time to be PRECISE.
PubMed 文献 · Br J Radiol · 2020-09-21

本研究回顾性分析196例经靶向活检确诊前列腺癌并接受主动监测的患者,比较T2WI上不同病灶测量定义与作为参考标准的手工勾画平面测量法的一致性,并按PRECISE评分分层比较年度体积变化百分比。椭球公式与平面测量法相关性最高(基线ρ=0.97、随访ρ=0.98),影像学消退/稳定(PRECISE 2-3)与进展(PRECISE 4-5)之间的年度体积变化百分比差异有统计学意义(p<0.001)。作者认为椭球公式可用于主动监测期间监测肿瘤生长。

要点

  • 椭球公式与平面测量法相关性最高:基线ρ=0.97、随访ρ=0.98,优于双径线测量和单最大径。
  • 按PRECISE评分分层,消退/稳定(2-3)与进展(4-5)的年度体积变化百分比差异有统计学意义(p<0.001)。
  • 作者认为椭球公式可作为平面测量法在T2WI上捕捉肿瘤体积变化的合理替代。

核心结论

  • 椭球公式可用于主动监测期间监测肿瘤生长。
  • 观察到影像学消退/稳定(PRECISE 2-3)与进展(PRECISE 4-5)之间的年度体积变化百分比差异有统计学意义。

研究设计与样本

  • 回顾性分析196例经靶向活检确诊前列腺癌并接受主动监测的患者,均有基线和随访两次MR扫描。
  • 病灶按所有定义在T2加权成像(T2WI)上测量,以平面测量法为参考标准,并为每例患者评定PRECISE评分。

关键影像表现/征象

  • 原文未涉及除病灶大小测量以外的影像征象描述。

诊断标准与关键数值

  • PRECISE标准以1-5分评估临床显著变化的可能性,4或5分提示影像学进展。
  • 索引病灶大小可按平面测量法、椭球公式或测量一个或两个径线等不同体积定义报告。
  • 椭球公式与平面测量法的相关性最高:基线ρ=0.97、随访ρ=0.98,高于双径线测量和单最大径。
  • 影像学消退/稳定(PRECISE 2-3)与进展(PRECISE 4-5)之间的年度体积变化百分比差异有统计学意义(p<0.001),平面测量法为39.64%、椭球公式为46.78%。

临床应用与阅片要点

  • 在影像引导的主动监测中,T2WI上可用椭球公式替代平面测量法捕捉肿瘤体积变化。
  • 报告病灶大小时可结合PRECISE评分描述影像学消退/稳定(2-3)或进展(4-5)。

局限性

  • 原文为回顾性分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The PRECISE criteria for reporting multiparametric MRI in patients on active surveillance (AS) for prostate cancer (PCa) score the likelihood of clinically significant change over time using a 1-5 scale, where 4 or 5 indicates radiological progression. According to the PRECISE recommendations, the index lesion size can be reported using different definitions of volume (planimetry or ellipsoid formula) or by measuring one or two diameters. We compared different measurements using planimetry as the reference standard and stratified changes according to the PRECISE scores.

METHODS: We retrospectively analysed 196 patients on AS with PCa confirmed by targeted biopsy who had two MR scans (baseline and follow-up). Lesions were measured on T2 weighted imaging (T2WI) according to all definitions. A PRECISE score was assessed for each patient.

RESULTS: The ellipsoid formula exhibited the highest correlation with planimetry at baseline (ρ = 0.97) and follow-up (ρ = 0.98) imaging, compared to the biaxial measurement and single maximum diameter. There was a significant difference (p < 0.001) in the yearly percentage volume change between radiological regression/stability (PRECISE 2-3) and progression (PRECISE 4-5) for planimetry (39.64%) and for the ellipsoid formula (46.78%).

CONCLUSION: The ellipsoid formula could be used to monitor tumour growth during AS. Evidence of a significant yearly percentage volume change between radiological regression/stability (PRECISE 2-3) and progression (PRECISE 4-5) has been also observed.

ADVANCES IN KNOWLEDGE: The ellipsoid formula is a reasonable surrogate for planimetry in capturing tumour volume changes on T2WI in patients on imaging-led AS. This is also associated with radiological changes using the PRECISE recommendations.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Giganti F, Stavrinides V, Stabile A, et al. Prostate cancer measurements on serial MRI during active surveillance: it's time to be PRECISE. Br J Radiol. 2020. PMID: 32955923. doi:10.1259/bjr.20200819

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。