文献速递泌尿生殖腹部US

多参数超声靶向前列腺癌:联合ARFI、SWEI、QUS与B模式

Multiparametric Ultrasound for Targeting Prostate Cancer: Combining ARFI, SWEI, QUS and B-Mode.
PubMed 文献 · Ultrasound Med Biol · 2020-09-28

研究用线性支持向量机将标准经直肠超声(TRUS)B模式数据与声辐射力脉冲(ARFI)成像、剪切波弹性成像(SWEI)及定量超声(QUS)中频带拟合数据融合为多参数超声容积,以增强病灶对比度。在20例患者训练验证、10例患者测试中,多参数超声在对比度、对比噪声比(CNR)和广义CNR(gCNR)上较标准TRUS B模式及SWEI有统计学显著改善。多参数超声提升了病灶可见性指标,作者认为其未来有望用于靶向TRUS引导前列腺穿刺活检。

要点

  • 多参数超声融合B模式、ARFI、SWEI与QUS中频带拟合数据,可提升前列腺病灶对比度与CNR。
  • ARFI虽仅在对比度上较B模式有统计学显著差异,但可捕捉识别病灶的关键定性特征。
  • 多参数超声在对比度、CNR、gCNR上较标准TRUS B模式和SWEI均有统计学显著改善。

关键影像表现/征象

  • 多参数超声较标准TRUS B模式和SWEI在对比度、CNR和gCNR上有统计学显著改善。
  • 多参数超声较MF在对比度和CNR上有统计学显著改善。
  • 多参数超声较ARFI在CNR上有统计学显著改善。
  • ARFI、MF和SWEI在对比度上均优于TRUS B模式,MF在CNR和gCNR上也优于B模式。
  • ARFI虽仅在对比度上较TRUS B模式有统计学显著差异,但可捕捉识别病灶的关键定性特征。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Diagnosing prostate cancer through standard transrectal ultrasound (TRUS)-guided biopsy is challenging because of the sensitivity and specificity limitations of B-mode imaging. We used a linear support vector machine (SVM) to combine standard TRUS imaging data with acoustic radiation force impulse (ARFI) imaging data, shear wave elasticity imaging (SWEI) data and quantitative ultrasound (QUS) midband fit data to enhance lesion contrast into a synthesized multiparametric ultrasound volume. This SVM was trained and validated using a subset of 20 patients and tested on a second subset of 10 patients. Multiparametric US led to a statistically significant improvements in contrast, contrast-to-noise ratio (CNR) and generalized CNR (gCNR) when compared with standard TRUS B-mode and SWEI; in contrast and CNR when compared with MF; and in CNR when compared with ARFI. ARFI, MF and SWEI also outperformed TRUS B-mode in contrast, with MF outperforming B-mode in CNR and gCNR as well. ARFI, although only yielding statistically significant differences in contrast compared with TRUS B-mode, captured critical qualitative features for lesion identification. Multiparametric US enhanced lesion visibility metrics and is a promising technique for targeted TRUS-guided prostate biopsy in the future.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Morris DC, Chan DY, Lye TH, et al. Multiparametric Ultrasound for Targeting Prostate Cancer: Combining ARFI, SWEI, QUS and B-Mode. Ultrasound Med Biol. 2020. PMID: 32988673. doi:10.1016/j.ultrasmedbio.2020.08.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。