动态双能CT虚拟单能重建计算血流灌注图:与传统动态80 kVp CT灌注的定量比较

Virtual monoenergetic reconstructions of dynamic DECT acquisitions for calculation of perfusion maps of blood flow: Quantitative comparison to conventional, dynamic 80 kVp CT perfusion.
PubMed 文献 · Eur J Radiol · 2020-08-31

研究对17例胰腺癌患者的动态双源双能CT采集(80kVp/Sn140kVp,每1.5秒一次共51秒)重建40–150 keV虚拟单能图像,用最大斜率模型计算血流灌注图并与80kVp图像比较。40–55 keV虚拟单能灌注图的标准差和绝对差-标准差比显著优于80kVp,但动态双能CT/虚拟单能采集的辐射剂量(8.0±3.7 mSv)高于动态80kVp采集(4.6±2.2 mSv)。

要点

  • 40–55 keV虚拟单能灌注图定量测量的稳健性和质量优于80kVp图像。
  • 低于110 keV时,虚拟单能图与80kVp图计算的血流灌注差异无统计学意义。
  • 动态双能CT/虚拟单能采集的辐射剂量高于动态80kVp采集。

诊断标准与关键数值

  • 健康组织血流从40 keV的114.3±37.2 mL/100 mL/min增至150 keV的128.6±58.9 mL/100 mL/min,胰腺癌血流从40 keV的45.6±25.3 mL/100 mL/min增至150 keV的75.5±49.8 mL/100 mL/min。
  • 多能80kVp图像的健康组织血流为114.2±37.4 mL/100 mL/min,胰腺癌血流为46.5±26.6 mL/100 mL/min。
  • 所有能量下健康组织与胰腺癌之间的血流差异均有统计学意义。
  • 低于110 keV时,虚拟单能图与80kVp图计算的血流灌注图差异无统计学意义。
  • 40–55 keV虚拟单能灌注图的标准差和绝对差-标准差比显著优于80kVp图像计算的灌注图。

局限性

  • 动态双能CT/虚拟单能采集的有效剂量(8.0±3.7 mSv)高于动态80kVp采集(4.6±2.2 mSv),患者辐射暴露增加。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Investigation of potential improvements in dynamic CT perfusion measurements by exploitation of improved visualization of contrast agent in virtual monoenergetic reconstructions of images acquired with dual-energy computed tomography (DECT).

METHOD: For 17 patients with pancreatic carcinoma, dynamic dual-source DECT acquisitions were performed at 80kVp/Sn140kVp every 1.5 s over 51 s. Virtual monoenergetic images (VMI) were reconstructed for photon energies between 40 keV and 150 keV (5 keV steps). Using the maximum-slope model, perfusion maps of blood flow were calculated from VMIs and 80kVp images and compared quantitatively with regard to blood flow measured in regions of interest in healthy tissue and carcinoma, standard deviation (SD), and absolute-difference-to-standard-deviation ratio (ADSDR) of measurements.

RESULTS: On average, blood flow calculated from VMIs increased with increasing energy levels from 114.3 ± 37.2 mL/100 mL/min (healthy tissue) and 45.6 ± 25.3 mL/100 mL/min (carcinoma) for 40 keV to 128.6 ± 58.9 mL/100 mL/min (healthy tissue) and 75.5 ± 49.8 mL/100 mL/min (carcinoma) for 150 keV, compared to 114.2 ± 37.4 mL/100 mL/min (healthy tissue) and 46.5 ± 26.6 mL/100 mL/min (carcinoma) for polyenergetic 80kVp. Differences in blood flow between tissue types were significant for all energies. Differences between perfusion maps calculated from VMIs and 80kVp images were not significant below 110 keV. SD and ADSDR were significantly better for perfusion maps calculated from VMIs at energies between 40 keV and 55 keV than for those calculated from 80kVp images. Compared to effective dose of dynamic 80kVp acquisitions (4.6 ± 2.2mSv), dose of dynamic DECT/VMI acquisitions (8.0 ± 3.7mSv) was higher.

CONCLUSIONS: Perfusion maps of blood flow based on low-energy VMIs between 40 keV and 55 keV offer improved robustness and quality of quantitative measurements over those calculated from 80kVp image data (reference standard), albeit at increased patient radiation exposure.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Skornitzke S, Kauczor HU, Stiller W, et al. Virtual monoenergetic reconstructions of dynamic DECT acquisitions for calculation of perfusion maps of blood flow: Quantitative comparison to conventional, dynamic 80 kVp CT perfusion. Eur J Radiol. 2020. PMID: 32942200. doi:10.1016/j.ejrad.2020.109262

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。