文献速递腹部MR

同步多层加速扩散加权成像以更高空间分辨率评估神经内分泌肿瘤肝转移患者

Simultaneous multi-slice accelerated diffusion-weighted imaging with higher spatial resolution for patients with liver metastases from neuroendocrine tumours.
PubMed 文献 · Clin Radiol · 2020-09-19

研究纳入15例神经内分泌肿瘤肝转移患者,比较常规DWI(层厚4 mm)与同步多层加速DWI(层厚2 mm,含和不含运动校正)对病灶的检出和描绘,并另在11名健康志愿者中评估重测变异性。运动校正SMS-DWI整体图像质量显著优于常规DWI,SMS-DWI和运动校正SMS-DWI检出病灶数更多且病灶描绘和ADC值更高。

要点

  • 运动校正SMS-DWI整体图像质量显著优于常规DWI(p<0.001),伪影显著更少(p=0.003)。
  • 常规DWI、SMS-DWI和运动校正SMS-DWI检出病灶数分别为348、504和523个。
  • SMS-DWI和运动校正SMS-DWI的病灶可检出性、描绘及ADC值均显著高于常规DWI(均p<0.001)。

关键影像表现/征象

  • 运动校正SMS-DWI整体图像质量显著优于常规DWI(p<0.001),伪影显著更少(p=0.003)。
  • 常规DWI、SMS-DWI和运动校正SMS-DWI检出高信号病灶数分别为348、504和523个。
  • SMS-DWI和运动校正SMS-DWI的病灶可检出性和描绘均显著高于常规DWI(均p<0.001)。
  • SMS-DWI和运动校正SMS-DWI的ADC值显著高于常规DWI(均p<0.001)。
  • 运动校正SMS-DWI在肝边缘附近区域的重测变异性显著高于常规DWI(p=0.018)。

临床应用与阅片要点

  • SMS-DWI可在相同采集时间内提供更高空间分辨率,有助于检出更多肝转移病灶并改善病灶描绘。
  • 运动校正SMS-DWI可减少伪影、改善整体图像质量,并改善肝边缘区域的重测变异性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the imaging characteristics of simultaneous multi-slice (SMS) accelerated diffusion-weighted imaging (DWI) with decreased section thickness, with and without motion correction, in comparison to conventional DWI (cDWI) for the detection of lesions in patients with neuroendocrine tumour (NET) liver metastases.

MATERIALS AND METHODS: Fifteen patients with NET liver metastases underwent cDWI (section thickness [SL]=4 mm) and SMS-DWI (SL=2 mm). Non-linear motion-corrected (Moco)-SMS-DWI was generated in addition to the original series. Qualitative imaging characteristics (five-point Likert scale), the number of high signal lesions, and the detectability and delineation of lesions were evaluated and compared using the Friedman and the Dunn-Bonferroni tests. The test-retest variability (TRV) of the cDWI and SMS-DWI techniques was investigated among 11 healthy volunteers who underwent cDWI (SL=4 mm) and SMS-DWI (SL=4 mm) twice. The Friedman and the Dunn-Bonferroni post-hoc tests were used to compare the mean apparent diffusion coefficient (ADC) and the TRV in different liver regions between the three series.

RESULTS: Moco-SMS-DWI demonstrated significantly superior overall image quality (p<0.001) with significantly fewer artefacts (p=0.003) than cDWI. The number of lesions detected by cDWI, SMS-DWI, and Moco-SMS-DWI were 348, 504, and 523, respectively. The detectability and delineation of the lesions and the ADC values were significantly higher on the SMS-DWI and Moco-SMS-DWI images than on the cDWI images (all p<0.001). Moco-SMS-DWI showed significantly higher TRV than cDWI in regions near the liver edge (p=0.018).

CONCLUSIONS: SMS-DWI achieves higher spatial resolution than cDWI within the same acquisition time, detects more lesions, and provides better lesion delineation. By applying motion correction, the TRV of DWI could be enhanced in regions near the liver edge.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Xu J, Cheng YJ, Wang ST, et al. Simultaneous multi-slice accelerated diffusion-weighted imaging with higher spatial resolution for patients with liver metastases from neuroendocrine tumours. Clin Radiol. 2020. PMID: 32962807. doi:10.1016/j.crad.2020.08.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。