文献速递腹部介入CT

肝细胞癌患者的CT肝脏灌注:能否修改采集方案以减少患者辐射暴露?

CT liver perfusion in patients with hepatocellular carcinoma: can we modify acquisition protocol to reduce patient exposure?
PubMed 文献 · Eur Radiol · 2020-09-02

回顾性分析24例肝细胞癌患者的CT肝脏灌注图像数据集,比较标准35次扫描方案与两种简化方案(18次奇数扫描间隔3.4秒、前18次扫描间隔1.7秒)对灌注参数准确性、鉴别效能及辐射暴露的影响。结果显示扫描间隔加倍不影响灌注参数及鉴别效能,而采集时间减半则显著改变参数并降低四种参数图的鉴别效能;修改方案减少48.5%的辐射暴露。

要点

  • 将CT肝脏灌注的扫描间隔从1.7秒加倍至3.4秒(18次扫描),肝细胞癌灌注参数不受影响且参数图鉴别效能保留。
  • 采集时间减半(前18次扫描,间隔1.7秒)会显著改变所有肝细胞癌灌注参数,并使四种参数图的鉴别效能显著下降。
  • 修改后的CT肝脏灌注采集方案可减少48.5%的患者辐射暴露。

诊断标准与关键数值

  • 扫描间隔加倍时,肝细胞癌灌注参数不受影响(p > 0.05),参数图鉴别效能保留(p < 0.05)。
  • 采集时间减半时,肝细胞癌所有灌注参数出现显著差异(p < 0.05),四种参数图的鉴别效能显著下降(p < 0.05)。
  • 修改后的CT肝脏灌注采集方案涉及的患者辐射暴露减少48.5%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the potential of decreasing the number of scans and associated radiation exposure involved in CT liver perfusion (CTLP) dynamic studies for hepatocellular carcinoma (HCC) assessment.

METHODS: Twenty-four CTLP image datasets of patients with HCC were retrospectively analyzed. All examinations were performed on a modern CT system using a standard acquisition protocol involving 35 scans with 1.7 s interval. A deconvolution-based or a standard algorithm was employed to compute ten perfusion parametric maps. 3D ROIs were positioned on 33 confirmed HCCs and non-malignant parenchyma. Analysis was repeated for two subsampled datasets generated from the original dataset by including only the (a) 18 odd-numbered scans with 3.4 s interval and (b) 18 first scans with 1.7 s interval. Standard and modified datasets were compared regarding the (a) accuracy of calculated perfusion parameters, (b) power of parametric maps to discriminate HCCs from liver parenchyma, and (c) associated radiation exposure.

RESULTS: When the time interval between successive scans was doubled, perfusion parameters of HCCs were found unaffected (p > 0.05) and the discriminating efficiency of parametric maps was preserved (p < 0.05). In contrast, significant differences were found for all perfusion parameters of HCCs when acquisition duration was reduced to half (p < 0.05), while the discriminating efficiency of four parametric maps was significantly deteriorated (p < 0.05). Modified CTLP acquisition protocols were found to involve 48.5% less patient exposure.

CONCLUSIONS: Doubling the interscan time interval may considerably reduce radiation exposure from CTLP studies performed for HCC evaluation without affecting the diagnostic efficiency of perfusion maps generated with either standard or deconvolution-based mathematical model.

KEY POINTS: • CT liver perfusion for HCC diagnosis/assessment is not routinely used in clinical practice mainly due to the associated high radiation exposure. • Two alternative acquisition protocols involving 18 scans of the liver were compared with the standard 35-scan protocol. • Increasing the time interval between successive scans to 3.4 s was found to preserve the accuracy of computed perfusion parameters derived with a standard or a deconvolution-based model and to reduce radiation exposure by 48.5%.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kalarakis G, Perisinakis K, Akoumianakis E, et al. CT liver perfusion in patients with hepatocellular carcinoma: can we modify acquisition protocol to reduce patient exposure? Eur Radiol. 2020. PMID: 32876834. doi:10.1007/s00330-020-07206-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。