多路复用灵敏度编码与单次激发回波平面成像在肝脏扩散加权成像中的比较
该研究纳入59例在3.0-T MRI系统上同时接受MUSE-DWI和cDWI的患者,由三名放射科医生独立定性评估并基于ROI测量定量参数。MUSE-DWI在图像噪声、肝脏轮廓锐利度、磁敏感伪影和病灶显著性方面均优于cDWI,肝脏SNR更高,病灶检出率更高(83.7% vs 67.3%,p=0.021),而病灶SNR、病灶-肝脏CNR及实性病灶定性诊断准确率无显著差异。
要点
- MUSE-DWI较cDWI图像噪声更少、肝脏轮廓更锐利、磁敏感伪影更轻、病灶显著性更好。
- MUSE-DWI肝脏SNR显著高于cDWI,右叶均值9.39 vs 8.10(p<0.001),左叶均值8.34 vs 7.19(p<0.001)。
- MUSE-DWI病灶检出率83.7%(41/49)优于cDWI 67.3%(33/49)(p=0.021)。
关键影像表现/征象
- 所有阅片者均发现MUSE-DWI较cDWI图像噪声更少、肝脏轮廓更锐利、磁敏感伪影更轻、病灶显著性更好(阅片者平均均值4.1-4.5 vs 3.5-4.0;p<0.05)。
- MUSE-DWI肝脏SNR显著高于cDWI:右叶均值9.39 vs 8.10(p<0.001),左叶均值8.34 vs 7.19(p<0.001)。
- MUSE-DWI与cDWI的病灶SNR(均值23.72 vs 23.88,p=0.911)和病灶-肝脏CNR(均值14.65 vs 15.41,p=0.527)相当。
- MUSE-DWI与cDWI对实性病灶的定性诊断准确率相当(阅片者平均AUC 0.985 vs 0.986,p=0.480)。
- MUSE-DWI病灶检出率优于cDWI(阅片者共识83.7%[41/49] vs 67.3%[33/49],p=0.021)。
诊断标准与关键数值
- MUSE-DWI与cDWI实性病灶定性诊断的阅片者平均AUC分别为0.985和0.986(p=0.480)。
- MUSE-DWI病灶检出率为83.7%(41/49),cDWI为67.3%(33/49)(p=0.021)。
- MUSE-DWI肝脏SNR右叶均值9.39、左叶均值8.34;cDWI右叶均值8.10、左叶均值7.19(右叶p<0.001,左叶p<0.001)。
临床应用与阅片要点
- MUSE-DWI较cDWI图像噪声更少、肝脏轮廓更锐利、磁敏感伪影更轻、病灶显著性更好,可用于改善肝脏DWI图像质量。
- MUSE-DWI肝脏SNR更高且病灶检出率更高,阅片时可关注其对病灶检出的提升。
- MUSE-DWI与cDWI的病灶SNR、病灶-肝脏CNR及实性病灶定性诊断AUC无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare multiplexed sensitivity encoding (MUSE) and conventional diffusion-weighted magnetic resonance imaging (cDWI) techniques in liver MRI.
METHODS: Fifty-nine patients who underwent both two-shot echo-planar DWI using MUSE and single-shot echo-planar cDWI at a 3.0-T MRI system were included. Qualitative parameters were independently evaluated by three radiologists, and quantitative parameters were calculated on the basis of region of interest measurements. Receiver operating characteristic curve analysis and McNemar's test were used to compare solid lesion characterization results and lesion detectability, respectively.
RESULTS: All reviewers found less image noise, sharper liver contours, milder susceptibility artifacts, and better lesion conspicuity in MUSE-DWI than in cDWI (reader average mean, 4.1-4.5 vs. 3.5-4.0; p < 0.05). The signal-to-noise ratio (SNR) of the liver was significantly higher in MUSE-DWI than in cDWI (right lobe: mean, 9.39 vs. 8.10, p < 0.001; left lobe: mean, 8.34 vs. 7.19, p < 0.001), while the SNR of the lesion (mean, 23.72 vs. 23.88, p = 0.911) and lesion-to-liver contrast-to-noise ratio (mean, 14.65 vs. 15.41, p = 0.527) were comparable between MUSE-DWI and cDWI. Solid lesion characterization results were comparably accurate between MUSE-DWI and cDWI (reader average area under the receiver operating characteristic curve, 0.985 vs. 0.986, p = 0.480). The detectability of lesions was better in MUSE-DWI than in cDWI (reader consensus, 83.7 % [41/49] vs. 67.3 % [33/49], p = 0.021).
CONCLUSION: MUSE-DWI can provide multi-shot liver DWI with less noise, fewer distortions, improved SNR of the liver, and better lesion detectability.
引用
- Kim YY, Kim MJ, Gho SM, et al. Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver. Eur J Radiol. 2020. PMID: 32992144. doi:10.1016/j.ejrad.2020.109292
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。