文献速递腹部CT

胰腺腺癌CT纹理分析:三维与二维肿瘤分割技术的比较

Pancreas adenocarcinoma CT texture analysis: comparison of 3D and 2D tumor segmentation techniques.
PubMed 文献 · Abdom Radiol (NY) · 2020-09-16

该回顾性研究纳入128例连续未治疗胰腺腺癌患者,比较三维全肿瘤分割与二维单层分割提取的CT纹理分析特征。除平均衰减、标准差和偏度外,其余特征中位数在两种分割间差异显著;仅平均衰减具有良好一致性(ICC 0.87),作者认为除平均HU外两种分割技术可能不可互换。

要点

  • 三维与二维分割的CT纹理特征多数不一致,仅平均衰减一致性良好(ICC 0.87)。
  • 平均衰减、标准差和偏度在两种分割间中位数无显著差异(P=0.2979)。
  • 除平均衰减外,其余纹理特征一致性差,报告纹理参数时需注明分割方法。

诊断标准与关键数值

  • 一阶特征包括平均、最小、最大HU、标准差、偏度、峰度、熵;二阶GLCM特征包括均匀性、对比度、相关性、熵和相异性。
  • 三维与二维分割中位数比较采用Mann-Whitney U检验及Holm-Bonferroni校正,相关性用Kendall秩相关Tau,一致性用双向模型单评分绝对一致性的ICC。
  • 平均衰减三维与二维分割中度相关(R=0.69,P<0.01),一致性良好(ICC=0.87,P<0.01)。
  • 最小值一致性中等(ICC=0.65,P<0.01),标准差一致性中等(ICC=0.56,P<0.01),其余特征一致性差。
  • 除平均衰减、标准差和偏度外(P=0.2979 each),其余特征中位数在三维与二维分割间差异显著。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine equivalency of multi-slice 3D CTTA and single slice 2D CTTA of pancreas adenocarcinoma.

METHODS: This retrospective study was research ethics board approved. Untreated pancreas adenocarcinomas were segmented on CT in 128 consecutive patients. Tumor segmentation was compared using two techniques: 3D segmentation by contouring all visible tumor in a 3D volume, and 2D segmentation using only a single axial image. First-order CTTA features including mean, minimum, maximum Hounsfield units (HU), standard deviation, skewness, kurtosis, entropy, and second-order gray-level co-occurrence matrix (GLCM) features homogeneity, contrast, correlation, entropy and dissimilarity were extracted. Median values were compared using the Mann-Whitney U test with Holm-Bonferroni correction. Kendall's Rank Correlation Tau assessed for correlation, and agreement was calculated using intraclass correlation coefficients (ICC) using a two-way model with single rating and absolute agreement. Statistical significance defined as P < 0.05.

RESULTS: The median values of CTTA features differed significantly between 3 and 2D segmentations for all of the evaluated features except for mean attenuation, standard deviation and skewness (P = 0.2979 each). 3D and 2D segmentations had moderate correlation for mean attenuation (R = 0.69, P < 0.01), while all other features demonstrated poor to fair correlation. Agreement between 3 and 2D segmentations was good for mean attenuation (ICC: 0.87, P < 0.01), moderate for minimum (ICC: 0.65, P < 0.01) and standard deviation (ICC: 0.56, P < 0.01), and poor for all other features.

CONCLUSION: While pancreas adenocarcinoma CTTA features obtained using 3D and 2D segmentation have multiple associations with clinically relevant outcomes, these segmentation techniques are likely not interchangeable other than for mean HU.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Kulkarni A, Carrion-Martinez I, Dhindsa K, et al. Pancreas adenocarcinoma CT texture analysis: comparison of 3D and 2D tumor segmentation techniques. Abdom Radiol (NY). 2020. PMID: 32939634. doi:10.1007/s00261-020-02759-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。