文献速递腹部外周血管技术与安全US

对比增强超声与多普勒超声检测胰腺移植物早期血管并发症的比较

Contrast-Enhanced Ultrasound Versus Doppler Ultrasound for Detection of Early Vascular Complications of Pancreas Grafts.
PubMed 文献 · AJR Am J Roentgenol · 2020-09-22

该回顾性研究由两名对患者结局设盲的放射科医生分析2017至2019年间34例胰腺移植物的术后多普勒超声和对比增强超声(CEUS)图像,其中28例未需手术再探查者为对照组,6例经手术再探查证实存在动脉或静脉异常。CEUS对血管异常的敏感度(两名读者均为83.3%)高于多普勒超声(66.7%和50.0%),特异度与多普勒超声相似,阴性预测值更高,读者间一致性也更高(κ=0.54 vs κ=0.28)。作者认为CEUS可能为放射科医生和外科医生提供及时有效评估胰腺移植物灌注的手段,并可能有助于识别可从手术挽救中获益的移植物。

要点

  • CEUS检测胰腺移植物血管异常的敏感度两名读者均为83.3%,高于多普勒超声的66.7%和50.0%。
  • CEUS的阴性预测值两名读者分别为96.9%和96.8%,高于多普勒超声的93.5%和91.4%。
  • CEUS的读者间一致性κ=0.54,高于多普勒超声的κ=0.28。

核心结论

  • 作者认为CEUS可能为放射科医生和外科医生提供术后及时有效评估胰腺移植物灌注的手段,并可能有助于识别可从手术挽救中获益的移植物。

研究设计与样本

  • 回顾性分析,两名对患者结局设盲的放射科医生分析2017至2019年间34例胰腺移植物的术后多普勒超声和CEUS图像。
  • 28例未需手术再探查的患者为对照组,6例经手术再探查证实存在动脉或静脉异常。
  • 每名放射科医生分别基于仅多普勒超声和仅CEUS的图像集将移植物血管性评分为正常或异常,并比较两种模式的诊断性能和读者间一致性。

诊断标准与关键数值

  • CEUS检测血管异常的敏感度两名读者均为83.3%,多普勒超声为读者1 66.7%、读者2 50.0%。
  • CEUS特异度读者1 81.6%、读者2 78.9%,多普勒超声读者1 76.3%、读者2 84.2%。
  • CEUS阴性预测值读者1 96.9%、读者2 96.8%,多普勒超声读者1 93.5%、读者2 91.4%。
  • 读者间一致性CEUS κ=0.54,多普勒超声 κ=0.28。

临床应用与阅片要点

  • 作者认为CEUS可能有助于术后及时有效评估胰腺移植物灌注,并可能帮助识别可从手术挽救中获益的移植物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to compare conventional duplex ultrasound and contrast-enhanced ultrasound (CEUS) for identifying vascular abnormalities in pancreas allografts in the immediate posttransplant setting. Identification of pancreas allografts at risk of failure may impact patient care because early intervention for vascular insufficiency can lead to graft salvage. MATERIALS AND METHODS. Two radiologists who were blinded to patient outcomes performed a retrospective analysis of the postoperative Doppler ultrasound and CEUS images of 34 pancreas grafts from transplants performed between 2017 and 2019. A total of 28 patients who did not require surgical reexploration were considered the control group. Six patients had surgically proven arterial or venous abnormalities on surgical reexploration. Each radiologist scored grafts as having normal or abnormal vascularity on the basis of image sets obtained using Doppler ultrasound only and CEUS only. Comparisons of both the diagnostic performance of each modality and interobserver agreement were performed. RESULTS. Both readers showed that CEUS had increased sensitivity for detecting vascular abnormalities (83.3% for both readers) compared with Doppler ultrasound (66.7% and 50.0%). For both readers, the specificity of CEUS was similar to that of Doppler imaging (81.6% and 78.9% for reader 1 and reader 2 versus 76.3% and 84.2% for reader 1 and reader 2). For both readers, the negative predictive value of CEUS was higher than that of Doppler ultrasound (96.9% and 96.8% for reader 1 and reader 2 versus 93.5% and 91.4% for reader 1 and reader 2). Interobserver agreement was higher for CEUS than for Doppler ultrasound (κ = 0.54 vs κ = 0.28). CONCLUSION. CEUS may provide radiologists and surgeons with a means of timely and effective evaluation of pancreas graft perfusion after surgery, and it may help identify grafts that could benefit from surgical salvage.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Swensson J, Hill D, Tirkes T, et al. Contrast-Enhanced Ultrasound Versus Doppler Ultrasound for Detection of Early Vascular Complications of Pancreas Grafts. AJR Am J Roentgenol. 2020. PMID: 32960665. doi:10.2214/AJR.20.22858

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。