急诊医生对无ST段抬高型心肌梗死胸痛患者区域性室壁运动异常的检测准确性
研究前瞻性纳入89例胸痛患者,3名急诊医生经每次3小时培训后用聚焦心脏超声检测区域性室壁运动异常,以盲法心脏科医生审阅录像为参考标准。结果显示敏感度76.9%(95%CI 56.4%-91.0%)、特异度92.1%(95%CI 82.4%-97.4%)、准确率87.6%(95%CI 79.0%-93.7%)、AUC 0.845(95%CI 0.753-0.913);作者认为经培训的急诊医生能准确排除区域性室壁运动异常。
要点
- 急诊医生经培训后以聚焦心脏超声检测区域性室壁运动异常,特异度92.1%、准确率87.6%。
- 敏感度76.9%(95%CI 56.4%-91.0%),AUC 0.845(95%CI 0.753-0.913)。
- 以盲法心脏科医生审阅预录视频为参考标准,急诊医生间一致性为0.83。
核心结论
- 作者认为,接受床旁超声培训的急诊医生能在疑似非ST段抬高型心肌梗死患者中准确排除区域性室壁运动异常。
研究设计与样本
- 前瞻性纳入胸痛患者,最终分析89例。
- 3名急诊医生接受由经验丰富心脏科医生提供的理论与实操培训,每次3小时。
- 急诊医生行聚焦心脏超声评估区域性室壁运动异常并录制图像,参考标准为盲法心脏科医生审阅预录视频。
- 原文报告校正样本量为82,急诊医生间一致性为0.83。
关键影像表现/征象
- 急诊医生用聚焦心脏超声检测区域性室壁运动异常,敏感度76.9%(95%CI 56.4%-91.0%),特异度92.1%(95%CI 82.4%-97.4%)。
诊断标准与关键数值
- 以盲法心脏科医生审阅预录视频作为检测区域性室壁运动异常的参考标准。
- 聚焦心脏超声检测区域性室壁运动异常的准确率为87.6%(95%CI 79.0%-93.7%),AUC为0.845(95%CI 0.753-0.913)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Our aim was to evaluate the accuracy of emergency physicians (EPs) in the detection of regional wall motion abnormalities (RWMAs) using focused cardiac ultrasound (FOCUS) in patients suspected of non-having ST-elevation myocardial infarction.
METHODS: We prospectively enrolled patients with chest pain. Three EPs underwent didactics and hands-on-training, of 3 hours each, by an experienced cardiologist, on detecting RWMAs using 2-dimensional echocardiography. They performed a FOCUS examination to evaluate for RWMAs and recorded the echo images. Our reference standard for the detection of RWMAs was accepted as a blinded cardiologist review of the prerecorded video clips. We calculated the corrected sample size and inter-rater agreement between the EPs (82 and 0.83, respectively). The analysis of the study was performed on 89 patients.
RESULTS: Eighty-nine patients with chest pain were screened. Emergency physicians demonstrated the detection of RWMAs with good sensitivity and even excellent specificity: 76.9% (95% confidence interval [CI], 56.4%- 91.0%) and 92.1% (95% CI, 82.4%-97.4%), respectively. The accuracy of FOCUS was 87.6% (95% CI, 79.0%-93.7%). The area under the curve from a receiver operating characteristic curve analysis, which evaluated the EPs' rate of detecting the presence or absence of RWMAs, was 0.845 (95% CI, 0.753-0.913).
CONCLUSIONS: Our study results suggest that EPs with training in bedside echocardiography can accurately rule in patients with RWMAs in suspected non-ST-elevation myocardial infarction cases.
引用
- Sağlam C, Ünlüer EE, Yamanoğlu NGÇ, et al. Accuracy of Emergency Physicians for Detection of Regional Wall Motion Abnormalities in Patients With Chest Pain Without ST-Elevation Myocardial Infarction. J Ultrasound Med. 2020. PMID: 32969533. doi:10.1002/jum.15513
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。