心电图门控与快速小角度激发双源CT扫描方案在经导管主动脉瓣置换术前评估中的对比研究

Evaluation of ECG-gated and Fast Low-Angle Shot (FLASH) Dual Source Computed Tomography Scanning Protocols for Transcatheter Aortic Valve Replacement.
PubMed 文献 · Acad Radiol · 2020-09-22

单中心队列研究纳入130例接受心电图门控CT与快速小角度激发双源CT血管成像(FLASH DS-CTA)的患者,评估TAVR术前主动脉瓣环测量及图像质量。两种方案测得的瓣环面积与周长相关性极好,FLASH DS-CTA辐射剂量显著更低,多数患者瓣膜尺寸选择一致。作者提出单次非门控FLASH DS-CTA可能提供全部术前影像信息。

要点

  • 心电图门控CT与FLASH DS-CTA测量的主动脉瓣环面积(R²=0.934)和周长(R²=0.923)相关性极好。
  • 仅2例(1.5%)患者两种方案瓣环测量差异>10%,瓣环周长无差异>10%者。
  • FLASH DS-CTA辐射剂量显著低于心电图门控CT(剂量长度乘积平均差404.38,95%CI 328.9-479.87,p<0.001)。

核心结论

  • FLASH DS-CTA与心电图门控CT在TAVR术前评估中提供相当的图像质量和主动脉瓣环尺寸。
  • FLASH DS-CTA还可提供主动脉及外周入路血管的血管造影成像,同时辐射剂量更低。
  • 作者提出单次非门控FLASH DS-CTA可能提供全部TAVR术前影像信息而无需门控CT扫描。

研究设计与样本

  • 单中心队列研究,纳入所有接受心电图门控和FLASH DS-CTA的患者,共130例(平均年龄81.5±9.2岁,46.2%女性,99.2%白人)。
  • 心电图门控心脏CT用于评估主动脉瓣环大小,FLASH DS-CTA用于检查主动脉及髂血管作为TAVR成像方案的一部分。
  • 对两种方案均进行容积重建以获得结构非矢状面视图,采用主动脉根部感兴趣区信噪比评估图像质量。

诊断标准与关键数值

  • 主动脉瓣环面积两种方案相关性R²=0.934,主动脉瓣环周长相关性R²=0.923。
  • 仅2例(1.5%)患者两种方案瓣环测量差异>10%,无患者瓣环周长差异>10%。
  • 信噪比两种方法无显著差异(平均差13.4,95%CI -2.1-28.8,p=0.09)。
  • FLASH DS-CTA辐射剂量显著低于心电图门控CT(剂量长度乘积平均差404.38,95%CI 328.9-479.87,p<0.001)。
  • 两种扫描测量导致相同经导管瓣膜尺寸选择:球囊扩张瓣膜尺寸推荐下128例(98.5%)患者一致,自膨胀瓣膜尺寸推荐下130例(100%)患者一致。

临床应用与阅片要点

  • 作者提出单次非门控FLASH DS-CTA可能用于提供全部TAVR术前影像信息而无需门控CT扫描。
  • FLASH DS-CTA可同时评估主动脉瓣环及主动脉、外周入路血管,并保持较低辐射剂量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Transcatheter aortic valve replacement (TAVR) procedural success relies heavily on volumetric reconstruction imaging, particularly ECG-gated multi-detector row computed tomography. We postulated that single examination using fast low-angle shot (FLASH) dual source CT scanning (DS-CTA) could provide lower dose than ECG-gated CTA while maintaining the image quality.

METHODS: In this single-centre cohort study, all patients who underwent ECG-gated and FLASH DS-CTA were evaluated. Volumetric reconstructions were performed for both ECG-gated and FLASH DS-CTA to obtain nonsagittal views of the structures. ECG-gated cardiac CT was obtained to evaluate the aortic annular size while FLASH DS-CTA was obtained to examine the aortic and iliac vasculature as part of TAVR imaging protocol. We evaluated measures of aortic annulus, coronaries and sinus of Valsalva using ECG-gated and FLASH DS-CTA scanning protocols. Image quality assessments were performed using aortic root region-of-interest signal-to-noise ratio.

RESULTS: A total of 130 patients (mean age 81.5 ± 9.2 years, 46.2% female, and 99.2% white) underwent both ECG-gated CT and FLASH DS-CTA. There were excellent correlations between aortic annular area (R2 = 0.934) and aortic annular perimeter (R2 = 0.923) measured by the two protocols. Only 2 (1.5%) patients had >10% difference between aortic annular measurements by ECG-gated and FLASH DS-CTA, while none of the patients had a >10% difference between aortic annular perimeter measured by ECG-gated and FLASH DS-CT scans. There was no significant difference in signal-to-noise ratio between the two methods (mean difference 13.4; 95% CI -2.1-28.8, p = 0.09). There was significantly lower radiation dose for FLASH DS-CTA than ECG-gated CT scan (mean dose-length product difference 404.38; 95% CI 328.9-479.87, p <0.001). The measurements by the two scans led to the same transcatheter valve size selection in majority of the 128 (98.5%) patients by balloon expandable valve sizing recommendations and 130 (100%) of patients by self-expanding valve sizing recommendations.

CONCLUSION: Overall, FLASH DS-CTA and ECG-gated CT scans provided comparable image quality and aortic annular dimensions for pre-TAVR evaluation. DS-CTA additionally provided the necessary angiographic imaging of the aorta and peripheral access vessels while still maintaining a lower radiation dose. We propose that a single non-ECG gated FLASH DS-CTA could be utilized to provide all the necessary pre-TAVR imaging information without a gated CT scan.