提高1.5-T非对比增强MR冠状动脉造影诊断冠状动脉疾病准确性的临床策略:全心与容积靶向成像联合应用
45例拟行常规冠状动脉造影的患者接受1.5-T自由呼吸非对比增强稳态自由进动MR冠状动脉造影,包括全心成像及后续三支血管容积靶向成像。联合MRCA诊断显著狭窄(直径减少≥50%)的敏感度97%、特异度83%、准确率93%,AUC在患者水平和血管水平均显著高于单纯全心MRCA,特异度显著提高。
要点
- 联合全心与容积靶向MRCA诊断显著CAD的敏感度97%、特异度83%、准确率93%。
- 联合MRCA的AUC在患者水平0.97、血管水平0.96,均显著高于单纯全心MRCA。
- 联合MRCA与全心MRCA敏感度相当,但特异度在患者水平(83% vs 25%)和血管水平(85% vs 50%)均显著提高。
核心结论
- 1.5-T非对比增强MRCA联合全心与容积靶向成像可高敏感度、中等特异度检出显著CAD,联合成像较单纯全心成像显著提高特异度。
研究设计与样本
- 45例拟行常规冠状动脉造影的患者接受1.5-T自由呼吸非对比增强稳态自由进动MRCA,包括全心成像及后续三支血管容积靶向成像;以CAG为参考标准。
诊断标准与关键数值
- 显著狭窄定义为直径减少≥50%;联合MRCA患者水平敏感度97%(95%CI 84-100%)、特异度83%(95%CI 52-98%)、准确率93%(95%CI 82-98%);联合MRCA的AUC患者水平0.97 vs 全心MRCA 0.85(p=0.0078),血管水平0.96 vs 0.86(p<0.0001);联合MRCA与全心MRCA特异度患者水平83% vs 25%(p=0.016),血管水平85% vs 50%(p<0.0001)。
临床应用与阅片要点
- 联合MRCA与冠状动脉CTA相当,可高敏感度、中等特异度检出CAD;联合成像较单纯全心成像提高诊断准确性,尤其是特异度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic performance of 1.5-T non-contrast MR coronary angiography (MRCA) for detection of coronary artery disease (CAD) using whole-heart imaging combined with volume-targeted imaging.
METHODS: Forty-five patients scheduled for conventional coronary angiography (CAG) underwent 1.5-T free-breathing non-contrast steady-state free-precession MRCA, including whole-heart and subsequent three-vessel volume-targeted imaging. Coronary stenosis was evaluated as follows: (1) by whole-heart MRCA alone; (2) by combined MRCA (whole-heart plus volume-targeted images). The diagnostic performance for significant stenosis (≥ 50% diameter reduction) was evaluated and compared using CAG as a reference standard.
RESULTS: Combined MRCA was completed in all 45 patients with a total acquisition time of 16.6 ± 3.3 min. The sensitivity, specificity, and accuracy of combined MRCA per patient were 97% (95% confidence interval 84-100%), 83% (52-98%), and 93% (82-98%), respectively. The areas under the receiver operating characteristic curve of combined MRCA were significantly higher than those of whole-heart MRCA on a per patient (0.97 versus 0.85, p = 0.0078) and per vessel (0.96 versus 0.86, p < 0.0001) basis. Compared with whole-heart MRCA, combined MRCA showed equally high sensitivity but significantly improved specificity on a per patient (83% versus 25%, p = 0.016) and per vessel (85% versus 50%, p < 0.0001) basis.
CONCLUSIONS: 1.5-T non-contrast MRCA combining whole-heart and volume-targeted imaging can detect significant CAD with high sensitivity and moderate specificity. Combined MRCA significantly improves specificity compared with whole-heart imaging alone.
KEY POINTS: • 1.5-T non-contrast MRCA with combined whole-heart and volume-targeted imaging can detect CAD with high sensitivity and moderate specificity comparable with coronary CTA. • Compared with whole-heart imaging alone, combined imaging provides improved diagnostic accuracy, especially specificity.
引用
- Lin L, Wang L, Zhang XN, et al. A clinical strategy to improve the diagnostic accuracy of 1.5-T non-contrast MR coronary angiography for detection of coronary artery disease: combination of whole-heart and volume-targeted imaging. Eur Radiol. 2020. PMID: 32975662. doi:10.1007/s00330-020-07135-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。