文献速递心血管MR

用于心脏植入式电子装置患者的高度加速实时自由呼吸电影CMR

Highly Accelerated Real-Time Free-Breathing Cine CMR for Patients With a Cardiac Implantable Electronic Device.
PubMed 文献 · Acad Radiol · 2020-09-02

本研究开发了16倍加速实时自由呼吸电影心血管磁共振序列,在13例心脏植入式电子装置患者中与临床标准屏气电影对比,实时序列扫描时间中位数缩短至3.7分之一, summed视觉评分中位数无显著差异(临床标准15.0 vs 实时14.5),LVEF平均差异-2%,结论为实时方法可产生临床可接受的评分和相对准确的LVEF。

要点

  • 实时自由呼吸电影CMR序列采用16倍加速、梯度回波读出、笛卡尔k空间采样和压缩感知重建。
  • 实时序列每层3.5个心跳,临床标准序列每层13个心跳(不含屏气间非扫描时间),扫描时间中位数缩短3.7倍。
  • summed视觉评分中位数临床标准15.0 vs 实时14.5,无显著差异;LVEF平均差异-2%(均值4.7%),一致性界限5.8%(均值13.5%)。

核心结论

  • 所提出的实时电影方法在心脏植入式电子装置患者中产生临床可接受的summed视觉评分和相对准确的LVEF。

研究设计与样本

  • 开发16倍加速实时自由呼吸电影CMR脉冲序列,采用梯度回波读出、笛卡尔k空间采样和压缩感知重建;扫描13例心脏植入式电子装置患者(平均年龄59岁,男9例/女4例),使用临床标准屏气电影和实时自由呼吸电影;两名临床读片者用五点Likert量表(1最差,3临床可接受,5最佳)对四个类别进行图像质量视觉评估,summed视觉评分为4项评分之和,12分定义为临床可接受;采用Wilcoxon符号秩检验比较summed视觉评分,Bland-Altman分析评估LVEF一致性。

诊断标准与关键数值

  • 图像质量视觉评估四个类别为舒张末期心内膜壁可见性、室壁运动时间保真度、心脏任何伪影水平、噪声,采用五点Likert量表(1最差,3临床可接受,5最佳);summed视觉评分为4项评分之和,12分定义为临床可接受;实时序列每层3.5个心跳,临床标准序列每层13个心跳(不含连续屏气采集间非扫描时间),扫描时间中位数实时缩短3.7倍;summed视觉评分中位数临床标准15.0 vs 实时14.5,无显著差异;LVEF平均差异-2%(均值4.7%),一致性界限5.8%(均值13.5%)。

临床应用与阅片要点

  • 作者认为所提出的实时电影方法在心脏植入式电子装置患者中产生临床可接受的summed视觉评分和相对准确的LVEF;阅片时可采用五点Likert量表评估图像质量,summed视觉评分≥12分视为临床可接受。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop a 16-fold accelerated real-time, free-breathing cine cardiovascular magnetic resonance (CMR) pulse sequence with compressed sensing reconstruction and test whether it is capable of producing clinically acceptable summed visual scores (SVS) and accurate left ventricular ejection fraction (LVEF) in patients with a cardiac implantable electronic device (CIED).

MATERIALS AND METHODS: A 16-fold accelerated real-time cine CMR pulse sequence was developed using gradient echo readout, Cartesian k-space sampling, and compressed sensing. We scanned 13 CIED patients (mean age = 59 years; 9/4 males/females) using clinical standard, breath-hold cine and real-time, free-breathing cine. Two clinical readers performed a visual assessment of image quality in four categories (conspicuity of endocardial wall at end diastole, temporal fidelity of wall motion, any artifact level on the heart, noise) using a five-point Likert scale (1: worst; 3: clinically acceptable; 5: best). SVS was calculated as the sum of 4 individual scores, where 12 was defined as clinical acceptable. The Wilcoxon signed-rank test was performed to compare SVS, and the Bland-Altman analysis was conducted to evaluate the agreement of LVEF.

RESULTS: Median scan time was 3.7 times shorter for real-time (3.5 heartbeats per slice) than clinical standard (13 heartbeats per slice, excluding nonscanning time between successive breath-hold acquisitions). Median SVS was not significantly different between clinical standard (15.0) and real-time (14.5). The mean difference in LVEF was -2% (4.7% of mean), and the limits of agreement was 5.8% (13.5% of mean).

CONCLUSION: This study demonstrates that the proposed real-time cine method produces clinically acceptable SVS and relatively accurate LVEF in CIED patients.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Hong S, Hong K, Culver AE, et al. Highly Accelerated Real-Time Free-Breathing Cine CMR for Patients With a Cardiac Implantable Electronic Device. Acad Radiol. 2020. PMID: 32888766. doi:10.1016/j.acra.2020.07.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。