文献速递胸部CT

疑似2019冠状病毒病患者CO-RADS的诊断准确性与观察者间变异性:一项多读者验证研究

Diagnostic accuracy and interobserver variability of CO-RADS in patients with suspected coronavirus disease-2019: a multireader validation study.
PubMed 文献 · Eur Radiol · 2020-09-23

该回顾性研究纳入2020年3月至5月间572例疑似COVID-19的连续有症状患者,12名不同经验水平的读者独立使用CO-RADS评分评估胸部CT。以RT-PCR为参考,CO-RADS≥4为最佳阈值,AUC为0.72(95%CI 66-78%),敏感度61%(95%CI 52-69%),特异度81%(95%CI 77-84%);全体读者间一致性中等(Fleiss K=0.43,95%CI 0.42-0.44)。作者认为CO-RADS诊断准确性高、读者间一致性中等,特异度高于既往认识,可能重新考虑CT在该临床情境中的作用。

要点

  • CO-RADS≥4为鉴别COVID-19肺部受累的最佳阈值,AUC 0.72(95%CI 66-78%)。
  • 该阈值下敏感度61%(95%CI 52-69%)、特异度81%(95%CI 77-84%)。
  • 不同经验读者间总体一致性中等(Fleiss K=0.43,95%CI 0.42-0.44)。

诊断标准与关键数值

  • CO-RADS评分≥4为最佳阈值,累积AUC为0.72(95%CI 66-78%)。
  • CO-RADS≥4阈值下,敏感度61%(95%CI 52-69%),特异度81%(95%CI 77-84%)。
  • 要点中报告平均AUC为0.72(95%CI 67-75%)。
  • 要点中报告CO-RADS≥4阈值下敏感度61%(95%CI 52-69%),特异度81%(95%CI 76-84%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To conduct a multireader validation study to evaluate the interobserver variability and the diagnostic accuracy for the lung involvement by COVID-19 of COVID-19 Reporting and Data System (CO-RADS) score.

METHODS: This retrospective study included consecutive symptomatic patients who underwent chest CT and reverse transcriptase-polymerase chain reaction (RT-PCR) from March 2020 to May 2020 for suspected COVID-19. Twelve readers with different levels of expertise independently scored each CT using the CO-RADS scheme for detecting pulmonary involvement by COVID-19. Receiver operating characteristic (ROC) curves were computed to investigate diagnostic yield. Fleiss' kappa statistics was used to evaluate interreader agreement.

RESULTS: A total of 572 patients (mean age, 63 ± 20 [standard deviation]; 329 men; 142 patients with COVID-19 and 430 patients without COVID-19) were evaluated. There was a moderate agreement for CO-RADS rating among all readers (Fleiss' K = 0.43 [95% CI 0.42-0.44]) with a substantial agreement for CO-RADS 1 category (Fleiss' K = 0.61 [95% CI 0.60-0.62]) and moderate agreement for CO-RADS 5 category (Fleiss' K = 0.60 [95% CI 0.58-0.61]). ROC analysis showed the CO-RADS score ≥ 4 as the optimal threshold, with a cumulative area under the curve of 0.72 (95% CI 66-78%), sensitivity 61% (95% CI 52-69%), and specificity 81% (95% CI 77-84%).

CONCLUSION: CO-RADS showed high diagnostic accuracy and moderate interrater agreement across readers with different levels of expertise. Specificity is higher than previously thought and that could lead to reconsider the role of CT in this clinical setting.

KEY POINTS: • COVID-19 Reporting and Data System (CO-RADS) demonstrated a good diagnostic accuracy for lung involvement by COVID-19 with an average AUC of 0.72 (95% CI 67-75%). • When a threshold of ≥ 4 was used, sensitivity and specificity were 61% (95% CI 52-69%) and 81% (95% CI 76-84%), respectively. • There was an overall moderate agreement for CO-RADS rating across readers with different levels of expertise (Fleiss' K = 0.43 [95% CI 0.42-0.44]).

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bellini D, Panvini N, Rengo M, et al. Diagnostic accuracy and interobserver variability of CO-RADS in patients with suspected coronavirus disease-2019: a multireader validation study. Eur Radiol. 2020. PMID: 32968883. doi:10.1007/s00330-020-07273-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。