全身MRI与1.5-T及3-T MRI系统配准PET/MRI同集成PET/CT对非小细胞肺癌TNM分期诊断准确性的比较
研究纳入104例病理确诊的非小细胞肺癌患者,比较全身MRI(1.5-T和3-T)、配准PET/MRI及PET/CT对TNM分期的诊断准确性。3-T全身MRI准确率88.5%、1.5-T全身MRI 84.6%、PET/MRI3T 86.5%、PET/MRI1.5T 81.7%,均显著优于PET/CT的76.0%;3-T全身MRI显著高于PET/MRI1.5T。结论认为全身MRI和配准PET/MRI与PET/CT相比同样准确或更准确,而3-T与1.5-T MRI系统间差异被认为不显著。
要点
- 3-T全身MRI的TNM分期诊断准确率最高(88.5%),显著优于PET/CT(76.0%)。
- 1.5-T全身MRI和配准PET/MRI(3-T及1.5-T)准确率均显著高于PET/CT。
- 3-T全身MRI准确率显著高于1.5-T配准PET/MRI(p=0.02)。
诊断标准与关键数值
- 3-T全身MRI的TNM分期诊断准确率为88.5%(92/104;p=0.0002),与最终诊断的Kappa值为0.87(p<0.0001)。
- 1.5-T全身MRI的TNM分期诊断准确率为84.6%(88/104;p=0.004),Kappa值为0.83(p<0.0001)。
- 3-T配准PET/MRI的TNM分期诊断准确率为86.5%(90/104;p=0.001),Kappa值为0.85(p<0.0001)。
- 1.5-T配准PET/MRI的TNM分期诊断准确率为81.7%(85/104;p=0.03),Kappa值为0.80(p<0.0001)。
- PET/CT的TNM分期诊断准确率为76.0%(79/104),Kappa值为0.73(p<0.0001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to compare diagnostic accuracy of TNM stage for whole-body MRI and coregistered PET/MRI using 1.5-T and 3-T MRI systems and PET/CT in patients with non-small cell lung cancer (NSCLC). SUBJECTS AND METHODS. A total of 104 patients with pathologically diagnosed NSCLC underwent whole-body MRI at 1.5 T and 3T and integrated PET/CT, as well as a combination of surgical, pathologic, or follow-up examinations. Whole-body MR images obtained by the five sequences were combined with the PET part of the PET/CT using proprietary software for the PET/MRI studies. The TNM stage obtained with all methods was visually assessed. Kappa statistics were used to determine agreement between TNM stage assessment and final diagnoses, and the McNemar test was used to compare diagnostic accuracy of all methods. RESULTS. Findings of TNM stage on whole-body MRI using 3-T (κ, 0.87; p < 0.0001) and 1.5-T (κ, 0.83; p < 0.0001) systems and for coregistered PET/MRI using a 3-T system (PET/MRI3T; κ, 0.85; p < 0.0001) were rated as significant and almost perfect, and findings for coregistered PET/MRI using a 1.5-T system (PET/MRI1.5T; κ, 0.80; p < 0.0001) and PET/CT (κ, 0.73; p < 0.0001) were rated significant and substantial. Diagnostic accuracy of whole-body MRI using the 3-T system was 88.5% (92/104; p = 0.0002, and using the 1.5-T system it was 84.6% (88/104; p = 0.004); results for PET/MRI3T and PET/MRI1.5T were 86.5% (90/104; p = 0.001) and 81.7% (85/104; p = 0.03), respectively, which were both significantly better than accuracy of results for PET/CT at 76.0% (79/104). Moreover, diagnostic accuracy of whole-body MRI using a 3-T system was significantly higher than that of PET/MRI using a 1.5-T system (p = 0.02). CONCLUSION. Whole-body MRI and coregistered PET/MRI using 3-T and 1.5-T systems are as accurate or more accurate than PET/CT, whereas differences between 3-T and 1.5-T MRI systems are not considered significant.
引用
- Ohno Y, Takeshi Y, Takenaka D, et al. Comparison of Diagnostic Accuracy for TNM Stage Among Whole-Body MRI and Coregistered PET/MRI Using 1.5-T and 3-T MRI Systems and Integrated PET/CT for Non-Small Cell Lung Cancer. AJR Am J Roentgenol. 2020. PMID: 32960670. doi:10.2214/AJR.19.22565
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。