文献速递心血管胸部外周血管US

床旁肺与下腔静脉超声在急诊急性失代偿性心力衰竭患者临床决策中的作用

Role of Point-of-Care Lung and Inferior Vena Cava Ultrasound in Clinical Decisions for Patients Presenting to the Emergency Department With Symptoms of Acute Decompensated Heart Failure.
PubMed 文献 · J Ultrasound Med · 2020-08-31

前瞻性队列研究纳入80例急诊急性失代偿性心力衰竭患者,于入院时及治疗3小时后行床旁肺超声与下腔静脉超声。结果显示B线数量及下腔静脉直径在入院与3小时之间差异有统计学意义,且住院与离院患者间存在显著差异;作者认为B线与下腔静脉直径评估优于B型利钠肽、射血分数或胸部X线,可用于住院或离院决策。

要点

  • 急诊疑似急性失代偿性心力衰竭时,床旁B线计数与下腔静脉直径测量可用于辅助诊断与住院/离院决策。
  • 治疗3小时后B线数量及下腔静脉吸气/呼气直径、塌陷指数较入院时有显著变化(P=.001)。
  • 射血分数及B型利钠肽水平与下腔静脉各指标之间均无显著相关性。

关键影像表现/征象

  • 入院与第3小时相比,下腔静脉吸气直径、呼气直径及下腔静脉塌陷指数差异有统计学意义(P=.001)。
  • 入院与第3小时相比,肺超声所有区域B线数量在3小时末均显著减少(P=.001)。
  • 住院患者与离院患者之间,下腔静脉直径及B线数量差异有统计学意义。

诊断标准与关键数值

  • 射血分数大于40%者46例(58%),射血分数小于40%者34例(42%)。
  • 射血分数与下腔静脉吸气直径(r=-0.03;P=.976)、呼气直径(r=-109;P=.336)、塌陷指数(r=-0.72;P=.523)均无相关性。
  • B型利钠肽水平与下腔静脉吸气直径(r=-0.58;P=.610)、呼气直径(r=-0.33;P=.774)、塌陷指数(r=-0.78;P=.493)均无相关性。

临床应用与阅片要点

  • 作者认为在急诊环境中评估B线及测量下腔静脉直径可用于急性失代偿性心力衰竭的诊断并辅助住院或离院决策。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This prospective study was performed to evaluate the diagnostic role of point-of-care lung ultrasound (LUS) and inferior vena cava (IVC) ultrasound in patients with acute decompensated heart failure (ADHF).

METHODS: A prospective cohort study was conducted between January 2018 and November 2018 on patients with a diagnosis of ADHF in the emergency department (ED). On admission, LUS findings, inspiratory and expiratory IVC diameters, and the inferior vena cava collapsibility index (IVCCI) were obtained. After therapeutic interventions, third-hour changes in LUS and the IVC index and the treatment response were assessed.

RESULTS: Eighty patients were enrolled. Forty-six (58%) patients had an ejection fraction (EF) greater than 40%, and 34 (42%) had an EF of less than 40%. Significant differences were detected between the admission and third-hour inspiratory IVC diameter, expiratory IVC diameter, and IVCCI (P = .001). There was no correlation between the EF and inspiratory IVC diameter (r = -0.03; P = .976), expiratory IVC diameter (r = -109; P = .336), or IVCCI (r = -0.72; P = .523) and between the B-type natriuretic peptide level and inspiratory IVC diameter (r = -0.58; P = .610), expiratory IVC diameter (r = -0.33; P = .774), or IVCCI (r = -0.78; P = .493) either. A comparison of admission and third-hour numbers of B-lines on LUS imaging showed a significant decrease in the number of B-lines in all zones at the end of 3 hours (P = .001). A significant difference existed between the hospitalized and discharged patients with respect to IVC diameters and number of B-lines.

CONCLUSIONS: In the ED setting, an assessment of B-lines and measurement of IVC diameters are better markers than the B-type natriuretic peptide level, EF, or chest x-ray for diagnosis of ADHF and can be used to make decisions for hospitalization or discharge from the ED.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Hacıalioğulları F, Yılmaz F, Yılmaz A, et al. Role of Point-of-Care Lung and Inferior Vena Cava Ultrasound in Clinical Decisions for Patients Presenting to the Emergency Department With Symptoms of Acute Decompensated Heart Failure. J Ultrasound Med. 2020. PMID: 32865243. doi:10.1002/jum.15447

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。