0.25毫米层厚与2048矩阵CT高空间分辨率成像预测肺腺癌侵袭性
该回顾性研究纳入89例接受0.25毫米层厚、2048矩阵高空间分辨率CT检查的肺腺癌患者,评估影像征象预测侵袭性(微浸润+浸润性腺癌)的诊断性能。调整年龄、性别和吸烟包年后,空气支气管造影中断和实性部分直径大于0.8厘米为独立预测因素,两者联合的敏感度为97%、特异度为86%、曲线下面积为0.94。
要点
- 高空间分辨率CT上空气支气管造影中断和实性部分>0.8厘米独立预测肺腺癌侵袭性。
- 两征象联合诊断侵袭性的敏感度97%、特异度86%、AUC 0.94。
- 分叶、毛刺、胸膜凹陷、实性部分不规则及居中、空气支气管造影异常等亦与侵袭性相关。
关键影像表现/征象
- 评估的征象包括分叶、毛刺、胸膜凹陷、血管集束、磨玻璃影均匀性、网状影、实性部分不规则及居中、空气支气管造影(不规则、中断或扩张)。
- 单因素分析显示分叶、毛刺、胸膜凹陷、实性部分不规则及居中、空气支气管造影中断和/或不规则扩张、总直径及实性部分直径与微浸润+浸润性腺癌相关(均P<.05)。
诊断标准与关键数值
- 空气支气管造影中断和实性部分直径大于0.8厘米为独立预测因素(P=.001和P=.02)。
- 两征象联合诊断侵袭性的敏感度97%(59/61例;95%CI:94%,100%),特异度86%(19/22例;95%CI:65%,97%),AUC 0.94。
- 总直径按≤1.6厘米或>1.6厘米评估,实性部分最长径按≤0.8厘米或>0.8厘米评估。
临床应用与阅片要点
- 阅片时关注高空间分辨率CT上空气支气管造影中断及实性部分直径是否大于0.8厘米,以辅助预测肺腺癌侵袭性。
- 结合分叶、毛刺、胸膜凹陷、实性部分不规则及居中等征象综合评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background High-spatial-resolution (HSR) CT provides detailed information and clear delineation of lung anatomy and disease states. HSR CT may have high diagnostic performance for predicting invasiveness of lung adenocarcinoma. Purpose To examine the diagnostic performance of HSR CT in predicting the invasiveness of lung adenocarcinoma. Materials and Methods In this retrospective study, 89 consecutive patients with adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IVA) were included who underwent surgery for lung cancer between January 2018 and December 2019. All patients underwent HSR CT with 0.25-mm section thickness and a 2048 matrix. Two independent observers evaluated the images for the presence or absence of the following HSR CT findings: lobulation, spiculation, pleural indentation, vessel convergence, homogeneity of ground-glass opacity, reticulation, irregularity and centrality of solid portion, and air bronchiologram (irregularity, disruption, or dilatation). The total diameter (≤1.6 cm or >1.6 cm) and the longest diameter of the solid portion (≤0.8 cm or >0.8 cm) were evaluated. Logistic regression models were used to identify findings associated with MIA plus IVA. Receiver operating characteristic analysis was performed to determine diagnostic performance. Results Eighty-nine patients (mean, 69 years ± 11 [standard deviation]; 49 men) were evaluated. The size of the nodules with invasion was a mean of 2.5 cm ± 1.2. Univariable analysis revealed lobulation, spiculation, pleural indentation, irregular and central solid portion, air bronchiologram with disruption and/or irregular dilatation, and total and solid portion diameters as associated with MIA plus IVA (all, P < .05). After adjustment for age, sex, and pack-years of smoking, disruption of air bronchogram and solid portion diameter greater than 0.8 cm remained as predictors of invasiveness (P = .001 and P = .02, respectively). The diagnostic performance of these two findings combined were as follows: sensitivity of 97% (59 of 61 patients; 95% confidence interval: 94%, 100%) and specificity of 86% (19 of 22 patients; 95% confidence interval: 65%, 97%), with an area under the curve of 0.94. Conclusion Using high-spatial-resolution CT, disruption of air bronchiologram and a solid portion greater than 0.8 cm were independently associated with a greater likelihood of invasiveness in lung adenocarcinoma. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Lynch and Oh in this issue.
引用
- Yanagawa M, Tsubamoto M, Satoh Y, et al. Lung Adenocarcinoma at CT with 0.25-mm Section Thickness and a 2048 Matrix: High-Spatial-Resolution Imaging for Predicting Invasiveness. Radiology. 2020. PMID: 32897161. doi:10.1148/radiol.2020201911
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。