文献速递胸部CT

使用半自动CT容积测量提高实性结节Lung-RADS分类的观察者间一致性

Improved Interobserver Agreement on Lung-RADS Classification of Solid Nodules Using Semiautomated CT Volumetry.
PubMed 文献 · Radiology · 2020-09-15

该回顾性研究由两名放射科医生和一名放射科住院医师对120例筛查CT中147个实性肺结节分别进行手动平均直径、半自动平均直径和半自动容积测量,并转换为Lung-RADS分类。所有测量方法的观察者间ICC均≥0.95,容积测量最高;Lung-RADS分类的κ值均≥0.81,手动测量最低、容积测量最高。基于容积测量,43/120(36%)的结节被至少一名读者归入更低的Lung-RADS分类,而反向情况仅4/120(3%)。

要点

  • 半自动CT容积测量在实性肺结节平均直径和容积测量中观察者间一致性最高,ICC≥0.95。
  • Lung-RADS分类的观察者间κ值均≥0.81,手动测量最低,容积测量最高。
  • 基于容积测量,36%的结节被至少一名读者归入更低Lung-RADS分类,仅3%归入更高分类。

核心结论

  • 手动直径测量的观察者间一致性高,半自动CT容积测量进一步提高一致性。
  • 半自动CT容积测量使更多结节被归入更低的Lung-RADS分类,而非手动或半自动直径测量。

研究设计与样本

  • 回顾性研究,纳入2016年9月至2018年6月筛查CT中临床Lung-RADS(1.0版)分类为2、3、4A或4B的肺结节。
  • 共120例患者(平均年龄63岁±6岁[标准差];67例女性),147个结节;两名放射科医生和一名放射科住院医师进行测量。
  • 所有三种测量方法均由三名读者在120/147个结节(82%)中获得。
  • 手动平均直径、半自动计算机辅助直径和容积测量均转换为相应的Lung-RADS分类。

诊断标准与关键数值

  • 所有读者对之间的组内相关系数(ICC)在所有测量方法中均≥0.95,容积测量最高。
  • 平均直径的偏倚和95%一致性界限在半自动测量中小于手动测量。
  • 所有Lung-RADS分类的κ值均≥0.81,手动测量最低,容积测量最高。
  • 基于容积测量,43/120(36%)的结节被至少一名读者归入更低Lung-RADS分类;反向情况为4/120(3%)。

临床应用与阅片要点

  • 半自动CT容积测量可提高实性肺结节Lung-RADS分类的观察者间一致性。
  • 采用容积测量可能使更多结节被归入更低Lung-RADS分类,阅片时需注意测量方法对分类的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Classification of lung cancer screening CT scans depends on measurement of lung nodule size. Information about interobserver agreement is limited. Purpose To assess interobserver agreement in the measurements and American College of Radiology Lung CT Screening Reporting and Data System (Lung-RADS) classifications of solid lung nodules detected at lung cancer screening using manual measurements of average diameter and computer-aided semiautomated measurements of average diameter and volume (CT volumetry). Materials and Methods Two radiologists and one radiology resident retrospectively measured lung nodules from screening CT scans obtained between September 2016 and June 2018 with a Lung-RADS (version 1.0) classification of 2, 3, 4A, or 4B in the clinical setting. Average manual diameter and semiautomated computer-aided diameter and volume measurements were converted to the corresponding Lung-RADS categories. Interobserver agreement in raw measurements was assessed using intraclass correlation and Bland-Altman indexes, and interobserver agreement in Lung-RADS classification was assessed using bi-rater κ. Results One hundred twenty patients (mean age, 63 years ± 6 [standard deviation]; 67 women) were evaluated. All manual, semiautomated diameter, and semiautomated volume measurements were obtained by all three readers in 120 of 147 nodules (82%). Intraclass correlation coefficients were greater than or equal to 0.95 for all reader pairs using all measurement methods and were highest using volumetry. Bias and 95% limits of agreement for average diameter were smaller with semiautomated measurements than with manual measurements. κ values across all Lung-RADS classifications were greater than or equal to 0.81, with the lowest being for manual measurements and the highest being for volumetric measurements. Forty-three of 120 (36%) of the nodules were classified into a lower Lung-RADS category on the basis of volumetry compared with using manual diameter measurements by at least one reader, whereas the reverse occurred for four of 120 (3%) of the nodules. Conclusion Interobserver agreement was high with manual diameter measurements and increased with semiautomated CT volumetric measurements. Semiautomated CT volumetry enabled classification of more nodules into lower Lung CT Screening Reporting and Data System categories than manual or semiautomated diameter measurements. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Nishino in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Gierada DS, Rydzak CE, Zei M, et al. Improved Interobserver Agreement on Lung-RADS Classification of Solid Nodules Using Semiautomated CT Volumetry. Radiology. 2020. PMID: 32930652. doi:10.1148/radiol.2020200302

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。