文献速递胸部技术与安全DR

COVID-19大流行期间胸部X线检查:放射科医生的真实世界阅片表现

Chest x-ray in the COVID-19 pandemic: Radiologists' real-world reader performance.
PubMed 文献 · Eur J Radiol · 2020-09-10

这项在米兰大学医院开展的回顾性观察研究纳入2020年2月24日至4月8日急诊就诊、12小时内完成鼻咽拭子RT-PCR和床旁前后位胸片的患者,以RT-PCR联合电话病史为复合参考标准,比较不同年资放射科医生阅片诊断表现。结果示高年资组(>10年)阅读435例(疾病患病率77.0%)敏感度89.0%、特异度66.0%、准确率83.7%;低年资组(<10年)阅读100例(患病率73.0%)敏感度89.0%、特异度40.7%、准确率76.0%。随疫情进展,整体敏感度由前半期80.8%升至后半期92.8%,特异度由67.7%降至53.2%,准确率由76.4%升至85.6%。

要点

  • 高年资组特异度66.0%、准确率83.7%,高于低年资组的40.7%和76.0%,敏感度两组均为89.0%。
  • 疫情后半期整体敏感度92.8%、准确率85.6%,均高于前半期的80.8%和76.4%,但特异度由67.7%降至53.2%。
  • 两组在后半期均表现为敏感度升高(高年资组92.7%、低年资组93.5%)而特异度下降(58.0%和33.3%)。

关键影像表现/征象

  • 高年资组阅读435例胸片,疾病患病率77.0%,敏感度89.0%、特异度66.0%、准确率83.7%。
  • 低年资组阅读100例胸片,疾病患病率73.0%,敏感度89.0%、特异度40.7%、准确率76.0%。
  • 疫情前半期共195例胸片、疾病患病率66.7%,整体敏感度80.8%、特异度67.7%、准确率76.4%;高年资组与低年资组敏感度相似(80.6%对81.5%),但高年资组特异度更高(74.0%对46.7%)、准确率更高(78.4%对69.0%)。
  • 疫情后半期共340例胸片、疾病患病率81.8%,整体敏感度升至92.8%、特异度降至53.2%、准确率升至85.6%;两组均表现为特异度下降(高年资组58.0%、低年资组33.3%)、敏感度升高(92.7%和93.5%)和准确率升高(86.5%和81.0%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To report real-world diagnostic performance of chest x-ray (CXR) readings during the COVID-19 pandemic.

METHODS: In this retrospective observational study we enrolled all patients presenting to the emergency department of a Milan-based university hospital from February 24th to April 8th 2020 who underwent nasopharyngeal swab for reverse transcriptase-polymerase chain reaction (RT-PCR) and anteroposterior bedside CXR within 12 h. A composite reference standard combining RT-PCR results with phone-call-based anamnesis was obtained. Radiologists were grouped by CXR reading experience (Group-1, >10 years; Group-2, <10 years), diagnostic performance indexes were calculated for each radiologist and for the two groups.

RESULTS: Group-1 read 435 CXRs (77.0 % disease prevalence): sensitivity was 89.0 %, specificity 66.0 %, accuracy 83.7 %. Group-2 read 100 CXRs (73.0 % prevalence): sensitivity was 89.0 %, specificity 40.7 %, accuracy 76.0 %. During the first half of the outbreak (195 CXRs, 66.7 % disease prevalence), overall sensitivity was 80.8 %, specificity 67.7 %, accuracy 76.4 %, Group-1 sensitivity being similar to Group-2 (80.6 % versus 81.5 %, respectively) but higher specificity (74.0 % versus 46.7 %) and accuracy (78.4 % versus 69.0 %). During the second half (340 CXRs, 81.8 % prevalence), overall sensitivity increased to 92.8 %, specificity dropped to 53.2 %, accuracy increased to 85.6 %, this pattern mirrored in both groups, with decreased specificity (Group-1, 58.0 %; Group-2, 33.3 %) but increased sensitivity (92.7 % and 93.5 %) and accuracy (86.5 % and 81.0 %, respectively).

CONCLUSIONS: Real-world CXR diagnostic performance during the COVID-19 pandemic showed overall high sensitivity with higher specificity for more experienced radiologists. The increase in accuracy over time strengthens CXR role as a first line examination in suspected COVID-19 patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Cozzi A, Schiaffino S, Arpaia F, et al. Chest x-ray in the COVID-19 pandemic: Radiologists' real-world reader performance. Eur J Radiol. 2020. PMID: 32971326. doi:10.1016/j.ejrad.2020.109272

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。