文献速递神经MR

术前识别原发性中枢神经系统淋巴瘤的归一化时间-强度曲线:一种分析DSC-PWI新方法的初步研究

Presurgical Identification of Primary Central Nervous System Lymphoma with Normalized Time-Intensity Curve: A Pilot Study of a New Method to Analyze DSC-PWI.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-09-17

本研究回顾性纳入233例患者(47例原发性中枢神经系统淋巴瘤、48例胶质母细胞瘤、39例间变性星形细胞瘤、49例转移瘤、50例脑膜瘤),设计了一种将DSC-PWI时间-强度曲线相对于正常白质进行归一化的新方法,并在测试子集中验证其对原发性中枢神经系统淋巴瘤的术前鉴别效能,各对比的AUC为0.83-0.96、准确率为71%-96%。

要点

  • 归一化时间-强度曲线在测试子集中鉴别原发性中枢神经系统淋巴瘤与胶质母细胞瘤的AUC=0.96、准确率93%。
  • 与间变性星形细胞瘤鉴别时AUC=0.83、准确率71%,为各对比中最低。
  • 与转移瘤和脑膜瘤鉴别时AUC分别为0.95和0.93,准确率分别为93%和96%。

关键影像表现/征象

  • 获取每个病例强化肿瘤与表现正常白质的时间-强度曲线,并将强化肿瘤曲线相对于表现正常白质进行归一化。
  • 通过逐步选择法确定曲线的最佳判别时间点,并应用逻辑二项回归获得预测模型。
  • 生成的算法在测试子集中应用,对原发性中枢神经系统淋巴瘤与其他各肿瘤类型的成对比较均表现满意。

诊断标准与关键数值

  • 原发性中枢神经系统淋巴瘤 vs 胶质母细胞瘤:AUC=0.96,准确率=93%。
  • 原发性中枢神经系统淋巴瘤 vs 间变性星形细胞瘤:AUC=0.83,准确率=71%。
  • 原发性中枢神经系统淋巴瘤 vs 转移瘤:AUC=0.95,准确率=93%。
  • 原发性中枢神经系统淋巴瘤 vs 脑膜瘤:AUC=0.93,准确率=96%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: DSC-PWI has demonstrated promising results in the presurgical diagnosis of brain tumors. While most studies analyze specific parameters derived from time-intensity curves, very few have directly analyzed the whole curves. The aims of this study were the following: 1) to design a new method of postprocessing time-intensity curves, which renders normalized curves, and 2) to test its feasibility and performance on the diagnosis of primary central nervous system lymphoma.

MATERIALS AND METHODS: Diagnostic MR imaging of patients with histologically confirmed primary central nervous system lymphoma were retrospectively reviewed. Correlative cases of glioblastoma, anaplastic astrocytoma, metastasis, and meningioma, matched by date and number, were retrieved for comparison. Time-intensity curves of enhancing tumor and normal-appearing white matter were obtained for each case. Enhancing tumor curves were normalized relative to normal-appearing white matter. We performed pair-wise comparisons for primary central nervous system lymphoma against the other tumor type. The best discriminatory time points of the curves were obtained through a stepwise selection. Logistic binary regression was applied to obtain prediction models. The generated algorithms were applied in a test subset.

RESULTS: A total of 233 patients were included in the study: 47 primary central nervous system lymphomas, 48 glioblastomas, 39 anaplastic astrocytomas, 49 metastases, and 50 meningiomas. The classifiers satisfactorily performed all bilateral comparisons in the test subset (primary central nervous system lymphoma versus glioblastoma, area under the curve = 0.96 and accuracy = 93%; versus anaplastic astrocytoma, 0.83 and 71%; versus metastases, 0.95 and 93%; versus meningioma, 0.93 and 96%).

CONCLUSIONS: The proposed method for DSC-PWI time-intensity curve normalization renders comparable curves beyond technical and patient variability. Normalized time-intensity curves performed satisfactorily for the presurgical identification of primary central nervous system lymphoma.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Pons-Escoda A, Garcia-Ruiz A, Naval-Baudin P, et al. Presurgical Identification of Primary Central Nervous System Lymphoma with Normalized Time-Intensity Curve: A Pilot Study of a New Method to Analyze DSC-PWI. AJNR Am J Neuroradiol. 2020. PMID: 32943424. doi:10.3174/ajnr.A6761

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。