儿童海马硬化诊断:自动化脑MRI体积测量与不同经验阅片者的比较
回顾性纳入22例经手术证实的海马硬化患儿及44例年龄性别匹配的颞叶外癫痫对照,比较全自动脑MRI体积测量工具与4名不同经验阅片者诊断儿童海马硬化的效能。体积工具与2名有经验儿科放射科医师及1名无经验住院医师效能无显著差异,但优于另一名无经验阅片者,且该阅片者使用工具后效能数值有所提高但未达统计学显著。
要点
- 全自动体积测量工具诊断儿童海马硬化的AUROC为0.813-0.980,与有经验阅片者效能相当。
- 体积工具优于其中一名无经验阅片者(AUROC 0.806),该阅片者使用工具后AUROC升至0.912但差异未达统计学显著(p=.10)。
- 海马硬化侧海马体积3.54 vs 对侧4.59 cm3、颞叶体积5.66 vs 6.89 cm3,均显著降低(p<.001)。
关键影像表现/征象
- 体积工具显示海马硬化组患侧海马体积3.54 vs 对侧4.59 cm3,患侧显著低于对侧(p<.001)。
- 体积工具显示海马硬化组患侧颞叶体积5.66 vs 对侧6.89 cm3,患侧显著低于对侧(p<.001)。
诊断标准与关键数值
- 体积工具诊断左侧海马硬化的AUROC为0.813-0.842,诊断右侧海马硬化的AUROC为0.857-0.980。
- 体积工具诊断海马硬化的敏感度为81.8%-90.9%,特异度为70.5%-95.5%。
- 两名有经验阅片者及一名无经验阅片者的AUROC为0.968-0.999,敏感度86.4%-90.9%,特异度100.0%,与体积工具效能无显著差异(p=.63至>.99)。
- 另一名无经验阅片者AUROC为0.806,敏感度81.8%,特异度47.7%,体积工具优于该阅片者(p<.001)。
临床应用与阅片要点
- 全自动体积测量工具可辅助儿童海马硬化的诊断,尤其对无经验阅片者有帮助。
- 无经验阅片者使用体积工具后AUROC由0.806升至0.912、敏感度由81.8%升至86.4%、特异度由47.7%升至84.1%,但差异未达统计学显著(p=.10)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. Hippocampal sclerosis (HS) is a leading cause of medically refractory temporal lobe epilepsy in children. The diagnosis is clinically important because most patients with HS have good postsurgical outcomes. OBJECTIVE. This study aimed to compare the performance of a fully automated brain MRI volumetric tool and readers of varying experience in the diagnosis of pediatric HS. METHODS. This retrospective study included 22 children with HS diagnosed between January 2009 and January 2020 who underwent surgery and an age- and sex-matched control group of 44 patients with normal MRI findings and extratemporal epilepsy diagnosed between January 2009 and January 2020. Regional brain MRI volumes were calculated from a high-resolution 3D T1-weighted sequence using an automated volumetric tool. Four readers (two pediatric radiologists [experienced] and two radiology residents [inexperienced]) visually assessed each MRI examination to score the likelihood of HS. One inexperienced reader repeated the evaluations using the volumetric tool. The area under the ROC curve (AUROC), sensitivity, and specificity for HS were computed for the volumetric tool and the readers. Diagnostic performances were compared using McNemar tests. RESULTS. In the HS group, the hippocampal volume (affected vs unaffected, 3.54 vs 4.59 cm3) and temporal lobe volume (affected vs unaffected, 5.66 vs 6.89 cm3) on the affected side were significantly lower than on the unaffected side (p < .001) using the volu-metric tool. AUROCs of the volumetric tool were 0.813-0.842 in patients with left HS and 0.857-0.980 in patients with right HS (sensitivity, 81.8-90.9%; specificity, 70.5-95.5%). No significant difference (p = .63 to > .99) was observed between the performance of the volumetric tool and the performance of the two experienced readers as well as one inexperienced reader (AUROCs for these three readers, 0.968-0.999; sensitivity, 86.4-90.9%; specificity, 100.0%). The volumetric tool had better performance (p < .001) than the other inexperienced reader (AUROC, 0.806; sensitivity, 81.8%; specificity, 47.7%). With subsequent use of the tool, this inexperienced reader showed a nonsignificant increase (p = .10) in AUROC (0.912) as well as in sensitivity (86.4%) and specificity (84.1%). CONCLUSION. A fully automated volumetric brain MRI tool outperformed one of two inexperienced readers and performed as well as two experienced readers in identifying and lateralizing HS in pediatric patients. The tool improved the performance of an inexperienced reader. CLINICAL IMPACT. A fully automated volumetric tool facilitates diagnosis of HS in pediatric patients, especially for an inexperienced reader.
引用
- Lee SB, Cho YJ, Jeon K, et al. Diagnosis of Hippocampal Sclerosis in Children: Comparison of Automated Brain MRI Volumetry and Readers of Varying Experience. AJR Am J Roentgenol. 2020. PMID: 32903057. doi:10.2214/AJR.20.23990
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。