文献速递神经头颈MR

两倍加速同时多层面读出分段回波平面扩散张量成像对三叉神经纤维束成像的评估

Evaluation of trigeminal nerve tractography using two-fold-accelerated simultaneous multi-slice readout-segmented echo planar diffusion tensor imaging.
PubMed 文献 · Eur Radiol · 2020-09-01

研究纳入8名健康对照和6名单侧三叉神经痛患者,在3T MRI上比较非SMS、SMS相同TR和SMS短TR三种RESOLVE-DTI协议对三叉神经的纤维束成像可靠性。结果显示三种协议测得的DTI指标一致,SMS协议信度良好,两倍加速可在几乎减半采集时间的同时获得可比的三叉神经纤维束和DTI指标。

要点

  • SMS RESOLVE-DTI可快速可靠评估三叉神经微观结构完整性。
  • 两倍加速RESOLVE-DTI获得的三叉神经纤维束和DTI指标与非SMS可比。
  • 三种协议组内和组间ICC均大于0.85,信度很好。

核心结论

  • SMS RESOLVE-DTI能够快速、可靠地评估三叉神经的微观结构完整性,可能应用于三叉神经痛的临床管理。
  • 两倍加速RESOLVE-DTI在几乎减半采集时间的同时,获得与非SMS可比的三叉神经纤维束和DTI指标。

研究设计与样本

  • 研究纳入8名健康对照和6名单侧三叉神经痛患者,均接受脑部MRI扫描。
  • 在3T MRI系统上执行三种RESOLVE-DTI协议:非SMS(TR=4330 ms)、SMS相同TR(4330 ms)和SMS短TR(2400 ms)。
  • 由两名独立评估者使用确定性纤维束成像和标准化追踪协议获取三叉神经纤维束的DTI指标及脑桥信噪比。

关键影像表现/征象

  • 视觉筛查显示三叉神经走行区未见伪影,所有数据均通过客观图像质量保证分析。
  • 脑桥信噪比在两种SMS协议间相似,非SMS RESOLVE-DTI的脑桥信噪比更高(F(2,36)=4.40,p=0.02)。
  • 三种协议间三叉神经DTI指标测量一致,非SMS与SMS衍生DTI指标间存在显著线性关系。

诊断标准与关键数值

  • 组内和组间组内相关系数(ICC)均大于0.85,信度很好。
  • 脑桥信噪比比较采用单因素方差分析,F(2,36)=4.40,p=0.02。

临床应用与阅片要点

  • 两倍加速SMS RESOLVE-DTI可在几乎减半采集时间的同时获得可靠的三叉神经纤维束成像和DTI指标,可能用于三叉神经痛的临床管理。
  • 两种SMS协议的脑桥信噪比相似,非SMS RESOLVE-DTI的脑桥信噪比更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Simultaneous multi-slice (SMS) imaging with short repetition time (TR) accelerates diffusion tensor imaging (DTI) acquisitions. However, its impact when combined with readout-segmented echo planar imaging (RESOLVE) on the cranial nerves given the challenging skull base/posterior fossa terrain is unexplored. We evaluated the reliability of trigeminal nerve DTI metrics using SMS with RESOLVE-DTI.

METHODS: Eight healthy controls and six patients with unilateral trigeminal neuralgia (TN) underwent brain MRI scan. Three different RESOLVE-DTI protocols were performed on a 3-T MRI system: non-SMS (TR = 4330 ms), SMS with identical TR (4330 ms), and SMS with short TR (2400 ms). Pontine signal-to-noise ratio (SNR) and DTI metrics of the trigeminal nerve streamlines tracked by two independent raters using deterministic tractography and standardized tracking protocol were obtained. These were statistically analyzed and compared across the three protocols using intra-rater and inter-rater intraclass correlation coefficients (ICCs), one-way analysis of variance (ANOVA), post hoc analysis, and linear regression.

RESULTS: On visual screening, there were no artifacts across the trigeminal nerves. All data also cleared objective image quality assurance analysis. Pontine SNR was similar for the two SMS protocols and higher for the non-SMS RESOLVE-DTI (F(2,36) = 4.40, p = 0.02). Intra-rater and inter-rater ICCs were very good (> 0.85). Trigeminal nerve DTI metrics were consistently measured by the three protocols, revealing significant linear relationships between non-SMS- and SMS-derived DTI metrics.

CONCLUSION: SMS RESOLVE-DTI enables fast and reliable evaluation of microstructural integrity of the trigeminal nerve, with potential application in the clinical management of TN.

KEY POINTS: • Readout-segmented diffusion-weighted echo planar imaging (RESOLVE-DTI) reduces image distortion artifacts in the posterior fossa but its long acquisition time limits clinical utility. • Simultaneous multi-slice (SMS) imaging combined with RESOLVE-DTI provides reliable trigeminal nerve tractography with potential applications in trigeminal neuralgia. • Two-fold-accelerated RESOLVE-DTI yields comparable trigeminal nerve streamlines and DTI metrics while near-halving acquisition time.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Koh YH, Shih YC, Lim SL, et al. Evaluation of trigeminal nerve tractography using two-fold-accelerated simultaneous multi-slice readout-segmented echo planar diffusion tensor imaging. Eur Radiol. 2020. PMID: 32870393. doi:10.1007/s00330-020-07193-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。