CT血管造影与CT灌注评估脑死亡确认中的脑循环停止
回顾性分析92例临床诊断脑死亡患者,最终纳入86例,比较三种CTA四点评分系统与CTP确认脑死亡的敏感性。ICV-SPV、A20-V60、A60-V60评分及CTP的敏感性分别为89.5%、82.6%、67.4%和93.3%;有颅骨缺损者CTP敏感性最高(86.5%)。
要点
- CTA不同四点评分系统确认脑死亡的敏感性存在差异,ICV-SPV评分敏感性最高但SPV评估困难。
- A20-V60评分敏感性高于A60-V60评分(82.6% vs 67.4%,p < 0.001)。
- 有颅骨缺损时CTP敏感性最高(86.5%,p = 0.019),可作为常规CTA方案的辅助。
关键影像表现/征象
- 基于静脉期大脑中动脉M4段和大脑内静脉显影的A60-V60评分系统敏感性为67.4%。
- 基于动脉期MCA-M4和静脉期ICV显影的A20-V60评分系统敏感性为82.6%。
- 基于静脉期ICV和岩上静脉显影的ICV-SPV评分系统敏感性为89.5%。
- 记录了开放性颅骨缺损和淤滞充盈的存在,淤滞充盈评估的观察者间一致性良好(κ=0.67)。
诊断标准与关键数值
- ICV-SPV评分系统确认脑死亡的敏感性为89.5%。
- A20-V60评分系统确认脑死亡的敏感性为82.6%。
- A60-V60评分系统确认脑死亡的敏感性为67.4%。
- CTP确认脑死亡的敏感性为93.3%;在有开放性颅骨缺损患者中CTP敏感性为86.5%(p = 0.019)。
- A20-V60评分敏感性高于A60-V60评分(p < 0.001)。
临床应用与阅片要点
- 在脑死亡确认中,CTA的敏感性依所用四点评分系统不同而异,报告时需注明所采用的评分系统。
- ICV-SPV评分最敏感,但岩上静脉评估具有挑战性。
- 作者认为,在常规脑死亡CTA方案中加入CTP,尤其对有开放性颅骨缺损的病例,可作为有用的辅助手段提高敏感性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the utility of computed tomography perfusion (CTP) and three different 4-point scoring systems in computed tomography angiography (CTA) in confirming brain death (BD) in patients with and without skull defects.
MATERIALS AND METHODS: Ninety-two patients clinically diagnosed as BD using CTA and/or CTP for confirmation were retrospectively reviewed. For the final analysis, 86 patients were included in this study. Images were re-evaluated by three radiologists according to the 4-point scoring systems that consider the vessel opacification on 1) the venous phase for both M4 segments of the middle cerebral arteries (MCAs-M4) and internal cerebral veins (ICVs) (A60-V60), 2) the arterial phase for the MCA-M4 and venous phase for the ICVs (A20-V60), 3) the venous phase for the ICVs and superior petrosal veins (ICV-SPV). The CTP images were independently reviewed. The presence of an open skull defect and stasis filling was noted.
RESULTS: Sensitivities of the ICV-SPV, A20-V60, A60-V60 scoring systems, and CTP in the diagnosis of BD were 89.5%, 82.6%, 67.4%, and 93.3%, respectively. The sensitivity of A20-V60 scoring was higher than that of A60-V60 in BD patients (p < 0.001). CTP was found to be the most sensitive method (86.5%) in patients with open skull defect (p = 0.019). Interobserver agreement was excellent in the diagnosis of BD, in assessing A20-V60, A60-V60, ICV-SPV, CTP, and good in stasis filling (κ: 0.84, 0.83, 0.83, 0.83, and 0.67, respectively).
CONCLUSION: The sensitivity of CTA confirming brain death differs between various proposed 4-point scoring systems. Although the ICV-SPV is the most sensitive, evaluation of the SPV is challenging. Adding CTP to the routine BD CTA protocol, especially in cases with open skull defect, could increase sensitivity as a useful adjunct.
引用
- Akdogan AI, Pekcevik Y, Sahin H, et al. Assessment of Cerebral Circulatory Arrest via CT Angiography and CT Perfusion in Brain Death Confirmation. Korean J Radiol. 2020. PMID: 32932559. doi:10.3348/kjr.2019.0859
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。