如何应对MR影像组学的多中心变异性?一种校正流程的验证
本研究验证ComBat协调方法能否消除MR影像组学特征的技术变异。体模、脑肿瘤和前列腺癌数据均显示,协调后不同场强或中心间特征分布差异基本消失,且区分Gleason分级的能力提高。作者认为ComBat可有效去除中心间技术不一致性并提高多扫描仪研究的敏感性。
要点
- ComBat协调后,体模42个特征中由协调前40个显著差异降至0个显著差异。
- 脑白质区FLAIR和CE-T1w各37/42个特征在1.5-T与3-T间显著差异,协调后均无显著差异。
- 前列腺癌数据协调后区分Gleason分级的显著特征数由461增至636,鉴别能力提高。
关键影像表现/征象
- 体模数据协调前42个影像组学特征值中40个在2台扫描仪间显著不同,协调后无一显著不同。
- 脑白质区FLAIR和CE-T1w图像中,各37/42个特征在1.5-T与3-T图像间统计分布显著不同(p < 0.05),协调后未观察到统计学显著差异。
- 脑肿瘤区FLAIR和CE-T1w图像中,协调前分别有41个和36个(共42个)特征在1.5-T与3-T图像间显著不同,协调后FLAIR仅1个、CE-T1w无显著不同。
诊断标准与关键数值
- 以统计分布差异检验(p < 0.05)评估协调前后1.5-T与3-T图像间影像组学特征值差异。
- 以前列腺癌Gleason分级为参照,比较协调前后区分Gleason分级的显著特征数:协调后636个 vs 协调前461个。
临床应用与阅片要点
- 多中心或多场强MR影像组学研究可考虑采用ComBat协调特征值,以减少技术变异对统计效能的影响。
- 该方法适用于不同MR序列和不同肿瘤类型的影像组学特征,且不依赖体模采集。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Test a practical realignment approach to compensate the technical variability of MR radiomic features.
METHODS: T1 phantom images acquired on 2 scanners, FLAIR and contrast-enhanced T1-weighted (CE-T1w) images of 18 brain tumor patients scanned on both 1.5-T and 3-T scanners, and 36 T2-weighted (T2w) images of prostate cancer patients scanned in one of two centers were investigated. The ComBat procedure was used for harmonizing radiomic features. Differences in statistical distributions in feature values between 1.5- and 3-T images were tested before and after harmonization. The prostate studies were used to determine the impact of harmonization to distinguish between Gleason grades (GGs).
RESULTS: In the phantom data, 40 out of 42 radiomic feature values were significantly different between the 2 scanners before harmonization and none after. In white matter regions, the statistical distributions of features were significantly different (p < 0.05) between the 1.5- and 3-T images for 37 out of 42 features in both FLAIR and CE-T1w images. After harmonization, no statistically significant differences were observed. In brain tumors, 41 (FLAIR) or 36 (CE-T1w) out of 42 features were significantly different between the 1.5- and 3-T images without harmonization, against 1 (FLAIR) or none (CE-T1w) with harmonization. In prostate studies, 636 radiomic features were significantly different between GGs after harmonization against 461 before. The ability to distinguish between GGs using radiomic features was increased after harmonization.
CONCLUSION: ComBat harmonization efficiently removes inter-center technical inconsistencies in radiomic feature values and increases the sensitivity of studies using data from several scanners.
KEY POINTS: • Radiomic feature values obtained using different MR scanners or imaging protocols can be harmonized by combining off-the-shelf image standardization and feature realignment procedures. • Harmonized radiomic features enable one to pool data from different scanners and centers without a substantial loss of statistical power caused by intra- and inter-center variability. • The proposed realignment method is applicable to radiomic features from different MR sequences and tumor types and does not rely on any phantom acquisition.
引用
- Orlhac F, Lecler A, Savatovski J, et al. How can we combat multicenter variability in MR radiomics? Validation of a correction procedure. Eur Radiol. 2020. PMID: 32975661. doi:10.1007/s00330-020-07284-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。