文献速递神经心血管CTMRUS

心脏CTA、心脏MRI与经胸超声心动图对心源性栓塞性卒中复发的预测价值

Predictive Value of Cardiac CTA, Cardiac MRI, and Transthoracic Echocardiography for Cardioembolic Stroke Recurrence.
PubMed 文献 · AJR Am J Roentgenol · 2021-06-16

该回顾性研究纳入151例疑似心源性栓塞性卒中患者,其中75例接受心脏MRI、76例接受心脏CTA,并均行经胸超声心动图。结果显示三种检查预测卒中复发的特异度和阴性预测值均较高,AUC无显著差异;作者认为心脏CTA和心脏MRI可能是经胸超声心动图的可行替代方案。

要点

  • 心脏CTA、心脏MRI与经胸超声心动图预测心源性栓塞性卒中复发的AUC无显著差异(p > .05)。
  • 心脏CTA组敏感度33.3%、特异度93.7%,心脏MRI组敏感度14.3%、特异度80.3%。
  • 心脏CTA检出心房和心室血栓3例,经胸超声心动图仅检出1例;心脏MRI检出1例,经胸超声心动图检出2例。

核心结论

  • 心脏CTA、心脏MRI和经胸超声心动图对心源性栓塞性卒中复发均显示较高的特异度和阴性预测值。
  • 作者认为心脏CTA和心脏MRI可能是经胸超声心动图的可行替代方案,鉴于心脏CTA可能更好地检出心房和心室血栓,或可优先选择。

研究设计与样本

  • 回顾性纳入2013年1月至2017年5月间151例疑似心源性栓塞性卒中患者,均行经胸超声心动图,其中心脏MRI组75例、心脏CTA组76例。
  • 评估左心房血栓、左心室血栓、易损主动脉斑块、心脏肿瘤和瓣膜赘生物作为心源性栓塞性卒中的病因,终点为卒中复发。

关键影像表现/征象

  • 心脏CTA组检出心房和心室血栓3例,经胸超声心动图检出1例;心脏MRI组心脏MRI检出1例,经胸超声心动图检出2例。

诊断标准与关键数值

  • 心脏CTA预测复发的敏感度33.3%、特异度93.7%、阳性预测值50.0%、阴性预测值88.2%。
  • 心脏MRI预测复发的敏感度14.3%、特异度80.3%、阳性预测值14.3%、阴性预测值80.3%。
  • 心脏MRI组中经胸超声心动图预测复发的敏感度14.3%、特异度83.6%、阳性预测值16.7%、阴性预测值80.9%。
  • 心脏CTA组中经胸超声心动图预测复发的敏感度8.3%、特异度93.7%、阳性预测值20.0%、阴性预测值84.5%。
  • 心脏CTA的AUC为0.63(95%CI 0.49-0.77),心脏MRI为0.53(95%CI 0.42-0.63),心脏MRI组经胸超声心动图为0.51(95%CI 0.40-0.61),心脏CTA组经胸超声心动图为0.51(95%CI 0.42-0.59),组间及组内比较p > .05。

临床应用与阅片要点

  • 心脏CTA、心脏MRI与经胸超声心动图预测心源性栓塞性卒中复发的临床效能相似,当经胸超声心动图结果不明确时这一观察可能尤为重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Apfaltrer G, Lavra F, De Cecco CN, et al. Predictive Value of Cardiac CTA, Cardiac MRI, and Transthoracic Echocardiography for Cardioembolic Stroke Recurrence. AJR Am J Roentgenol. 2021. PMID: 32936016. doi:10.2214/AJR.20.23903