瞬发伽马成像识别异质区域解剖变化所致局部质子射程偏差
本研究在颅底肿瘤质子治疗中,用瞬发伽马相机记录多个分次,并以评估CT发现鼻窦腔填充减少;比较测量与模拟的瞬发伽马剖面,在一个照射野中检出因解剖变化导致的平均约3 mm射程偏差,另两个照射野预测的射程变化未能检出。
要点
- 瞬发伽马成像可在异质区域检出部分因解剖变化引起的局部质子射程偏差。
- 一个照射野中,穿过鼻窦腔区域的部分笔形束斑点检出平均约3 mm的射程偏差。
- 另两个照射野受解剖变化影响较小,预测的射程变化未能检出。
核心结论
- 首次临床应用瞬发伽马成像,检出了异质区域解剖变化所致部分预期的小范围局部质子射程偏差。
- 该技术存在若干局限性,可能限制其在异质区域检测射程偏差的敏感度。
研究设计与样本
- 本研究为质子治疗中瞬发伽马成像的临床可行性研究,对颅底靶区患者治疗进行多个分次的瞬发伽马相机记录。
- 以评估CT显示治疗过程中鼻窦腔填充减少作为解剖变化依据,比较测量与模拟的瞬发伽马剖面,分析计划与实测笔形束斑点位置的射程变化。
诊断标准与关键数值
- 一个照射野中,穿过鼻窦腔区域的笔形束斑点子集检出因解剖变化所致平均约3 mm的射程偏差。
- 另两个照射野受解剖变化影响较小,预测的射程变化未能检出。
- 上述结果与基于评估CT的模拟部分一致。
临床应用与阅片要点
- 原文未据此给出临床推荐。
局限性
- 该技术存在若干局限性,可能限制其在异质区域检测射程偏差的敏感度。
- 另两个照射野预测的射程变化未能检出。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Prompt gamma (PG) imaging has previously been demonstrated for use in proton range verification of a brain treatment with a homogeneous target region. In this study, the feasibility of PG imaging to detect anatomic change within a heterogeneous region is presented.
METHODS: A prompt gamma camera recorded several fractions of a patient treatment to the base of skull. An evaluation CT revealed a decrease in sinus cavity filling during the treatment course. Comparison of PG profiles between measurement and simulation was performed to investigate range variations between planned and measured pencil beam spot positions.
RESULTS: For one field, an average over range of 3 mm due to the anatomic change could be detected for a subset of spots traversing the sinus cavity region. The two other fields appeared less impacted by the change but predicted range variations could not be detected. These results were partially consistent with the simulations of the evaluation CT.
CONCLUSION: We report the first clinical application of PG imaging that detected some of the expected small regional proton range deviations due to anatomic change in a heterogeneous region. However, several limitations exist with the technology that may limit its sensitivity to detect range deviations in heterogeneous regions.
ADVANCES IN KNOWLEDGE: We report on the first detection of range variations due to anatomic change in a heterogeneous region using PGI. The results confirm the feasibility of using PG-based range verification in highly heterogeneous target regions to identify deviations from the treatment plan.
引用
- Xie Y, Petzoldt J, Janssens G, et al. Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region. Br J Radiol. 2020. PMID: 32960655. doi:10.1259/bjr.20190619
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。