指南与共识胸部CT

基于RSNA共识分类标准的COVID-19 CT评估中观察者间与观察者内变异性

Interobserver and Intraobserver Variability in the CT Assessment of COVID-19 Based on RSNA Consensus Classification Categories.
指南 / 共识 · Acad Radiol · 2020-09-15

该研究让5名胸部专科放射科医师、5名非胸部专科放射科医师和5名五年级放射科住院医师对70例PCR确诊或排除COVID-19的胸部CT按RSNA四类分类法进行两轮分类,结果显示各组观察者间一致性为中等(κ 0.45-0.52),观察者内一致性在胸部与非胸部组为高度(κ 0.61-0.67)、住院医师组为中等(κ 0.58),结论支持RSNA共识分类系统的可靠性。

要点

  • RSNA四类分类法在不同年资放射科医师中观察者间一致性为中等(κ 0.45-0.52)。
  • 胸部与非胸部专科医师的观察者内一致性为高度(κ 0.61-0.67),住院医师为中等(κ 0.58)。
  • 以PCR结果为参照,各组内总体一致性均为中等。

核心结论

  • 研究结果支持RSNA共识分类系统用于COVID-19相关影像表现的可靠性。

研究设计与样本

  • 调查研究,纳入70例经PCR确诊COVID-19阳性和COVID-19阴性的胸部CT。
  • 参与者为三组放射科医师:5名胸部专科培训放射科医师、5名非胸部专科培训放射科医师、5名五年级放射科住院医师。
  • 参与者将每例胸部CT按RSNA COVID-19四类影像分类法进行分类,并选择导致分类的影像特征。
  • 间隔1周洗脱期后,从初始调查中随机选取检查进行第二次调查。

诊断标准与关键数值

  • 各组观察者间总体一致性为中等,κ系数范围0.45-0.52±0.02。
  • 胸部与非胸部组观察者内总体一致性为高度,κ系数范围0.61-0.67±0.06;住院医师组观察者内总体一致性为中等,κ系数0.58±0.06。
  • 导致分类的影像特征在观察者间和观察者内一致性水平不一,κ值范围从一般到完全一致。
  • 以PCR确诊COVID状态为参照,各组内总体一致性均为中等。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the interobserver and intraobserver agreement of fellowship trained chest radiologists, nonchest fellowship-trained radiologists, and fifth-year radiology residents for COVID-19-related imaging findings based on the consensus statement released by the Radiological Society of North America (RSNA).

METHODS: A survey of 70 chest CTs of polymerase chain reaction (PCR)-confirmed COVID-19 positive and COVID-19 negative patients was distributed to three groups of participating radiologists: five fellowship-trained chest radiologists, five nonchest fellowship-trained radiologists, and five fifth-year radiology residents. The survey asked participants to broadly classify the findings of each chest CT into one of the four RSNA COVID-19 imaging categories, then select which imaging features led to their categorization. A 1-week washout period followed by a second survey comprised of randomly selected exams from the initial survey was given to the participating radiologists.

RESULTS: There was moderate overall interobserver agreement in each group (κ coefficient range 0.45-0.52 ± 0.02). There was substantial overall intraobserver agreement across the chest and nonchest groups (κ coefficient range 0.61-0.67 ± 0.06) and moderate overall intraobserver agreement within the resident group (κ coefficient 0.58 ± 0.06). For the image features that led to categorization, there were varied levels of agreement in the interobserver and intraobserver components that ranged from fair to perfect kappa values. When assessing agreement with PCR-confirmed COVID status as the key, we observed moderate overall agreement within each group.

CONCLUSION: Our results support the reliability of the RSNA consensus classification system for COVID-19-related image findings.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Hadied MO, Patel PY, Cormier P, et al. Interobserver and Intraobserver Variability in the CT Assessment of COVID-19 Based on RSNA Consensus Classification Categories. Acad Radiol. 2020. PMID: 32948442. doi:10.1016/j.acra.2020.08.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。