文献速递胸部CT

COVIDiag:基于CT表现诊断COVID-19肺炎的临床计算机辅助诊断系统

COVIDiag: a clinical CAD system to diagnose COVID-19 pneumonia based on CT findings.
PubMed 文献 · Eur Radiol · 2020-08-01

本研究纳入612例患者(306例COVID-19与306例非COVID-19肺炎),提取20个CT影像特征,用五种分类器评估自动鉴别效能。集成分类器COVIDiag获得AUC 0.965、敏感度93.54%、特异度90.32%、准确率91.94%,作者认为可作为放射科医生的辅助工具。

要点

  • 病变位置与分布、病灶数目、磨玻璃影与铺路石征、实变、网格影、支气管壁增厚、结节、空气支气管征、空洞、胸腔积液、胸膜增厚及淋巴结增大为鉴别COVID-19与非COVID-19肺炎的显著CT特征。
  • 集成分类器COVIDiag鉴别COVID-19的AUC为0.965,敏感度93.54%、特异度90.32%、准确率91.94%。
  • 放射科医生诊断的AUC为0.879,敏感度87.10%、特异度88.71%、准确率87.90%。

关键影像表现/征象

  • 病变位置与分布模式、病灶数目、磨玻璃影与铺路石征、实变、网格影、支气管壁增厚、结节、空气支气管征、空洞、胸腔积液、胸膜增厚及淋巴结增大为区分COVID-19组与非COVID-19组的显著特征。

诊断标准与关键数值

  • 集成分类器(COVIDiag)鉴别COVID-19与非COVID-19的AUC为0.965,敏感度93.54%、特异度90.32%、准确率91.94%。
  • 放射科医生诊断的AUC为0.879,敏感度87.10%、特异度88.71%、准确率87.90%。

临床应用与阅片要点

  • 作者认为COVIDiag模型可作为放射科医生在当前COVID-19大流行期间做出准确诊断的辅助工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: CT findings of COVID-19 look similar to other atypical and viral (non-COVID-19) pneumonia diseases. This study proposes a clinical computer-aided diagnosis (CAD) system using CT features to automatically discriminate COVID-19 from non-COVID-19 pneumonia patients.

METHODS: Overall, 612 patients (306 COVID-19 and 306 non-COVID-19 pneumonia) were recruited. Twenty radiological features were extracted from CT images to evaluate the pattern, location, and distribution of lesions of patients in both groups. All significant CT features were fed in five classifiers namely decision tree, K-nearest neighbor, naïve Bayes, support vector machine, and ensemble to evaluate the best performing CAD system in classifying COVID-19 and non-COVID-19 cases.

RESULTS: Location and distribution pattern of involvement, number of the lesion, ground-glass opacity (GGO) and crazy-paving, consolidation, reticular, bronchial wall thickening, nodule, air bronchogram, cavity, pleural effusion, pleural thickening, and lymphadenopathy are the significant features to classify COVID-19 from non-COVID-19 groups. Our proposed CAD system obtained the sensitivity, specificity, and accuracy of 0.965, 93.54%, 90.32%, and 91.94%, respectively, using ensemble (COVIDiag) classifier.

CONCLUSIONS: This study proposed a COVIDiag model obtained promising results using CT radiological routine features. It can be considered an adjunct tool by the radiologists during the current COVID-19 pandemic to make an accurate diagnosis.

KEY POINTS: • Location and distribution of involvement, number of lesions, GGO and crazy-paving, consolidation, reticular, bronchial wall thickening, nodule, air bronchogram, cavity, pleural effusion, pleural thickening, and lymphadenopathy are the significant features between COVID-19 from non-COVID-19 groups. • The proposed CAD system, COVIDiag, could diagnose COVID-19 pneumonia cases with an AUC of 0.965 (sensitivity = 93.54%; specificity = 90.32%; and accuracy = 91.94%). • The AUC, sensitivity, specificity, and accuracy obtained by radiologist diagnosis are 0.879, 87.10%, 88.71%, and 87.90%, respectively.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Abbasian Ardakani A, Acharya UR, Habibollahi S, et al. COVIDiag: a clinical CAD system to diagnose COVID-19 pneumonia based on CT findings. Eur Radiol. 2020. PMID: 32740817. doi:10.1007/s00330-020-07087-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。